IMPORTANT : THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE
Important Safety Advice
When using electrical appliances, basic precautions
should always be followed to reduce the risk of fire,
electrical shock, and injury to persons, including the
following:
IMPORTANT – The wall brackets supplied with the
appliance must be used.
IMPORTANT – If the heater is installed in a room containing
a bath or shower, it must be so installed that switches
and other controls cannot be touched by a person using
a bath or shower.
Do not use outdoors.
Do not locate the heater immediately below a fixed socket
outlet or connection box.
Do not cover the heater. Do not place material or garments
on the heater, or obstruct the air circulation around the
heater, for instance by curtains or pushing furniture up
against the heater, as this could cause overheating and a
fire risk.
NEVER cover or obstruct in any way the heat outlet slots
at the top of the heater or the air inlet slots in the base of
the heater.
WARNING – THE SURFACES OF THIS HEATER CAN BE HOT.
Momentary contact with any part of the heater should
not cause injury. However, aged or infirm persons or
young children should not be left unsupervised in the
vicinity of the heater unless a suitable guard is fitted.
This appliance is not intended for use by children or other
persons without assistance or supervision if their
physical, sensory or mental capabilities prevent them
from using it safely. Children should be supervised to
ensure that they do not play with the appliance.
Note that due care and consideration must be taken when
using this heater in series with a thermal control, a
program controller, a timer or any other device that
switches on the heat automatically, since a fire risk exists
when the heater is accidentally covered or displaced.
If the supply cord is damaged it must be replaced by the
manufacturer or service agent or a similarly qualified
person in order to avoid a hazard.
WARNING: IN ORDER TO AVOID OVERHEATING, DO NOT COVER
THE HEATER.
Electrical
WARNING – THIS APPLIANCE MUST BE EARTHED
The electrical installation must be carried out by a competent
electrician, and be in strict accordance with the current I.E.E.
regulations for Electrical Equipment in Buildings.
Watts
A
B
750
620
108
750
620
108
1250
688
108
1250
688
108
1500
688
108
1500
688
108
2000
860
108
2000
860
108
Installation and Operating Instructions
150
MIN
Fig. 1
The heater is fitted with a length of flexible cable type H05VV-F size
3 x 1.0mm
2
, for connection to the fixed wiring of the premises through
a suitable connection box positioned adjacent to the heater.
The supply circuit to the heater must incorporate a double pole isolating
switch having a contact separation of at least 3mm.
Supplementary Earth Bonding
Should Equipotential Earth Bonding be required the earthing conductor
in the supply cord is deemed to provide the supplementary bonding
connection (see Regulation 547-03-05, 16
Regulations).
General
The
Panel heater is designed for wall mounting on the wall brackets
supplied. It should only be operated when in the upright position as
shown.
All models are splashproof to IP24 standard.
UPX.... TI models are fitted with a 24 hour programme timer.
Before connecting the
same as that stated on the heater.
Wall Mounting
IMPORTANT – The wall brackets supplied with the appliance must
be used. The heater should be positioned observing the minimum
clearances stated around the heater - see Fig. 1.
DO NOT locate the heater immediately below a fixed socket outlet or
connection box.
1.
Remove wall mounting bracket from the back of the heater
by depressing the spring latch at the top of each bracket -
see Fig. 2.
2.
Fix the wall bracket securely to the wall through the four
screw holes provided.
3.
Present the heater to the wall bracket, and engage lower
slots in the back with bracket.
4.
Raise the heater to upright position and push the heater onto
brackets to engage top latch.
Access to the controls
To open the hinged controls cover, insert the blade of a screwdriver
in the small slot on the right hand side of the cover, and gently lever
the screwdriver outwards. Note: After adjustment of the controls
the control cover must be closed.
INUDUKP572
A
th
Edition I.E.E. Wiring
heater check that the supply voltage is the
255
MIN
Issue 0
B
150
MIN
430
150
MIN
Fig. 2

Advertisement

loading

Summary of Contents for Dimplex Unidare UPX Series

  • Page 1 UNIDARE Installation and Operating Instructions INUDUKP572 Issue 0 UPX.. Panel Heaters Dimensions (millimetres) Model(s) Watts UPX750 UPX750TI UPX1250 1250 UPX1250TI 1250 UPX1500 1500 UPX1500TI 1500 UPX2000 2000 UPX2000TI 2000 Fig. 1 IMPORTANT : THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE The heater is fitted with a length of flexible cable type H05VV-F size Important Safety Advice 3 x 1.0mm...
  • Page 2 Hampshire. SO30 2DF Republic of Ireland Tel. 01 8424833 [ C] Glen Dimplex UK Limited All rights reserved. Material contained in this publication may not be reproduced in whole or part, without prior permission in writing from Glen Dimplex UK Limited.

This manual is also suitable for:

Unidare upx750Unidare upx750ti 750Unidare upx1250 1250Unidare upx1250tiUnidare upx1500Unidare upx1500ti ... Show all