INSTALLATION INSTRUCTIONS
C-WP-C-RDC Series
3L AND 6L
CAUTIONS
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety
precautions should always be followed including the
following:
READ AND FOLLOW ALL
SAFETY INSTRUCTIONS
1.
DANGER- Risk of shock- Disconnect power before
installation.
DANGER – Risque de choc – Couper l'alimentation
avant l'installation.
2.
This Product Must Be Installed In Accordance With The
Applicable Installation Code By A Person Familiar With
The Construction And Operation Of The Product And The
Hazards Involved.
Ce Produit Doit Être Installé Selon Le Code D'installation
Pertinent, Par Une Personne Qui Connaît Bien Le
Produit Et Son Fonctionnement Ainsi Que Les Risques
Inhérents.
3.
Suitable for wet locations.
Convient aux emplacements mouilles.
4.
Wall mount only.
Installation murale seulement
SAVE THESE INSTRUCTIONS
FOR FUTURE REFERENCE
10L AND 16L
http://lighting.cree.com/warranty
Document:
LPN00675X0001A2_A
Created By:
TMT
MOUNTING OVER RECESSED JUNCTION BOX
NOTE: Knockouts are provided for mounting over 3" octagonal or 4"
octagonal boxes.
1. Remove lens assembly by loosening screws on side of frame.
Swing lens assembly open,disconnect quick connect wiring
connector(s) and lift lens assembly upward to remove from housing.
2. Drill out appropriate knockouts in back box for attachment to junction
box. Also drill knockout for wiring access.
NOTE: Fixture should not be exclusively supported by junction
box. Drill additional knockouts toward corners of fixture to provide
additional support. Do NOT drill within 1/4" (64 mm) from edges of
fixture.
3. Pull supply leads from junction box through wall of back box. Attach
back box to mounting surface using hardware (supplied by others)
appropriate for mounting surface.
NOTE: A high grade caulking material such as silicone rubber,
should be used around perimeter of back box to prevent water
leakage into fixture or junction box.
4. Position switches to select desired CCT and wattage. See Figure 1.
NOTE: Factory setting for wattage is highest setting. Factory setting
for CCT is 4000K.
5. Make wiring connections per the Electrical Connections section.
6. Replace the lens assembly on hinges, re-connect quick-connect
wiring connectors, and swing lens into place. Re-tighten screws that
were loosened in Step 1.
WALL MOUNTED WITH CONDUIT FEED
1. Remove lens assembly by loosening screws on side of frame.
Swing lens assembly open,disconnect quick connect wiring
connector(s) and lift lens assembly upward to remove from housing.
2. Drill holes in four corners of back box to allow for attachment of
back box to mounting surface. Do NOT drill within 1/4" (64 mm)
from edges of fixture.
3. Attach back box to mounting surface using hardware (supplied by
others) appropriate for mounting surface.
NOTE: A high grade caulking material such as silicone rubber,
should be used around perimeter of back box to prevent water entry.
4. Remove appropriate threaded plugs on sides of fixture and route
electrical conduit to the holes desired. Feed the supply leads through
the conduit and into the back box.
NOTE: Use of teflon tape on the conduit threads will ensure a
watertight seal.
5. Position switches to select desired CCT and wattage. See Figure 1.
NOTE: Factory setting for wattage is highest setting. Factory setting
for CCT is 4000K.
6. Make wiring connections per the Electrical Connections section.
7. Replace the lens assembly on hinges, re-connect quick-connect
wiring connectors, and swing lens into place. Re-tighten screws that
were loosened in Step 1.
FIGURE 1
|
1-800-236-6800
Date
12-2-2022

Advertisement

loading

Summary of Contents for C-LITE C-WP-C-RDC Series

  • Page 1 LPN00675X0001A2_A Date 12-2-2022 INSTALLATION INSTRUCTIONS Created By: C-WP-C-RDC Series MOUNTING OVER RECESSED JUNCTION BOX NOTE: Knockouts are provided for mounting over 3" octagonal or 4" octagonal boxes. 1. Remove lens assembly by loosening screws on side of frame. Swing lens assembly open,disconnect quick connect wiring connector(s) and lift lens assembly upward to remove from housing.
  • Page 2: Installation Instructions

    Document: LPN00675X0001A2_A Date 12-2-2022 INSTALLATION INSTRUCTIONS Created By: C-WP-C-RDC Series ELECTRICAL CONNECTIONS FCC NOTICE Fixture is equipped with universal volt driver 120-277V CAUTION: Changes or modifications not expressly approved could void (ie. 120V, 208V, 240V or 277V) your authority to use this equipment.
  • Page 3: Medidas De Seguridad Importantes

    Documento: LPN00675X0001A2_A Fecha 12-02-2022 INSTRUCCIONES DE INSTALACIÓN Creado por: Serie C-WP-C-RDC INSTALACIÓN SOBRE UNA CAJA DE CONEXIONES EMPOTRADA NOTA: Incluye orificios precortados para instalarse sobre cajas de cone- xiones octagonales de 3” (76 mm) y 4” (101 mm). 1. Retire el conjunto del lente afl ojando los tornillos en el costado del marco.
  • Page 4: Conexiones Eléctricas

    Documento: LPN00675X0001A2_A Fecha 12-02-2022 INSTRUCCIONES DE INSTALACIÓN Creado por: Serie C-WP-C-RDC CONEXIONES ELÉCTRICAS AVISO DE LA FCC La luminaria está equipada con un controlador de voltaje universal PRECAUCIÓN: Los cambios o modificaciones que no se autoricen de 120-277 V expresamente podrían invalidar su autoridad para usar este equipo. (es decir, 120 V, 208 V, 240 V o 277 V) CABLEADO DE FASE A NEUTRO 120/277 V Este dispositivo cumple con la Sección 15 de las normas de la FCC.
  • Page 5: Mesures De Sécurité Importantes

    Document : LPN00675X0001A2_A Date 12-02-2022 INSTRUCTIONS D’INSTALLATION Créé par : Série C-WP-C-RDC INSTALLATION AU-DESSUS UNE BOÎTE DE JONCTION ENCASTRÉE REMARQUE : Des alvéoles défonçables sont prévues pour l’installation sur des boîtes octogonales de 76 mm (3 po) ou 102 mm (4 po). 1.
  • Page 6: Instructions D'installation

    Document : LPN00675X0001A2_A Date 12-02-2022 INSTRUCTIONS D’INSTALLATION Créé par : Série C-WP-C-RDC RACCORDEMENTS ÉLECTRIQUES AVIS DE LA FCC Le luminaire est équipé d’un pilote de tension universelle de MISE EN GARDE : Toute modification ou tout changement non ex- 120 à 277 V pressément approuvé...

This manual is also suitable for:

C-wp-c-rdc-s3l-scct-dbC-wp-c-rdc-s16l-scct-db