Download Print this page
Datalogic ID-NET QL Series Instructions
Datalogic ID-NET QL Series Instructions

Datalogic ID-NET QL Series Instructions

Advertisement

Quick Links

QL300 / QL500
Quick Link ID-NET™ Connectors
DESCRIPTION
The QL series ID-NET™ connectors provide a fast and efficient way to
cable an ID-NET™ network using standard cables. The QL300/500s are
typically Master ID-NET™ connectors designed to be used with the
QL100/150/200s ID-NET™ Slave connectors.
The QL300 is a passive connection module which can be used in
Standalone or ID-NET™ Master Multidata, Slave Multidata or Master
Synchronized layouts. It provides separate ports for Power Supply,
External Trigger, Digital I/O and Communication. Host communication is
provided through connectivity to the reader Main serial interface
(RS232/485) or Aux RS232 serial interface.
ID-NET™ network and power supply signals are sent out to the next
connected device by means of a dedicated port, however input power is
not received from the network. Therefore each QL300 must be powered
separately.
The QL500 is an active connection module which can be used in
Standalone or ID-NET™ Master Multidata, or Master Synchronized
layouts. It provides separate ports for Power Supply, External Trigger,
Digital I/O and Communication. Host communication is provided through
the integrated Ethernet module which connects internally to the reader's
Main serial interface. Reader Aux RS232 serial interface is also provided.
ID-NET™ network and power supply signals are sent out to the next
connected device by means of a dedicated port, however there is no
network input connector and therefore it cannot be used as an ID-NET™
Slave.
The QL series are compatible with the following readers:
DS2100N
DS4800
Matrix 400™
DS2400N
Matrix 200™
QL300
QL500
821001641 (Rev. A)
CONNECTIONS
ID-NET Out
M12 5P Female (A-coded)
Pin
Function
1
Shield
2
Vdc
3
GND
4
ID+
5
ID-
QL300 only
(ID-NET In)
M12 5P Male (A-coded)
Pin
Function
1
Shield
2
nc
3
GND
4
ID+
5
ID-
QL500 only
(Ethernet)
RJ45 8P Female
Pin
Function
1
TX+
2
TX-
3
RX+
P8
P1
6
RX-
4, 5, 7, 8
nc
OVERALL DIMENSIONS
129
[4.56]
45
42
[1.49]
[1.59]
QL300
129
[4.56]
42
45
[1.49]
[1.59]
QL500
Power
M12 3P Male (B-coded)
Pin
Function
1
Earth
2
Vdc
3
GND
Trigger
M12 4P Female (A-coded)
Pin
Function
1
+V
2
nc
3
-V
4
I1+
MOUNTING
There are two self-threading screws provided for mounting the QLs to
various wooden or plastic surfaces. Mounting to other surfaces such as
concrete walls or metallic panels requires user-supplied parts (screws,
screw anchors, nuts, etc). Keep in mind that the connected reader must
have its Chassis grounded to Earth, see paragraph "Grounding".
QLs can also be mounted to a Bosch Frame using the BA200 mounting
accessory.
The distance between mounting bushings is given in the overall
dimension diagram for each QL.
IP65 protection is provided when the cables (or QLs)
are properly mated.
NOTE
GROUNDING
There are two general rules to follow regarding network grounding:
1) The network Shield must only be connected to Earth ground at
one point (the Master).
When using isolated power supplies, Earth grounding can be
mm
accomplished through the CAB-PW-EXT accessory cable and the
in
BA400 or QL300/500 Power connector.
CAB-PW-EXT
Power Supply
Earth ground connection
2) All reader Chassis must be connected to Earth ground.
All the readers in the network must have their Chassis connected to
Earth ground either by: mounting to conductive metal brackets or
frames which are connected to Earth ground; or through the CBX or
SC4000; or through the QL bushing.
In the case of grounding through the CBX or SC4000, connect the
Earth signal to a good earth ground and set the internal Chassis
jumper to Earth.
In the case of grounding through the QL bushing, connect a flying
lead from the mounting bushing to an Earth ground. The mounting
bushing is internally connected to the reader Chassis.
mm
in
13
Reader
25P D-Sub Female
Pin
Function
1,
shell,
Reader Chassis
both bushings
2
TXM
3
RXM
4
RTSM *
5
CTSM *
6
I2A
7
GND
8
O1+
9
nc
10
I2B
11
O2+
12
O2-
13
Vdc
* pins 4 and 5 are nc for QL500.
I/O Port
15P HD D-Sub Female
Pin
Function
1
O1+
2
TXA
3
RXA
4
RXM *
5
CTSM *
6
O1-
7
Vdc
8
O2+
* pins 4, 5, 12 and 15 are nc for QL500.
Do not connect GND and SGND to different (external)
ground references. GND and SGND are internally
connected through filtering circuitry which can be
permanently damaged if subjected to voltage drops over
0.8 Vdc.
CAUTION
ACCESSORIES
Description
QL300
Power
Cables
CAB-PW-EXT M12 POWER
EXTENSION CABLE
CBL-1480-01 THIN M12/5P
MALE/FEMALE 1M
CBL-1480-02 THIN M12/5P
MALE/FEMALE 2M
CAB-AUX04 15P DSUB TO DB9
SERIAL CABLE 3M
Terminators
CBL-1490 TERM. RESIST.
THIN M12/5P/MALE
CBL-1496 TERM. RESIST.
THIN M12/5P/FEMALE
Field Mountable Connectors
FMC400 M12 3P F. CONN. POWER
Mounting
BA200 Bosch Adaptors
The FMC accessory connectors can be used to make custom External
Power and Service cables in case the standard cables don't satisfy the
application requirements.
1
25
14
Pin
Function
14
nc
15
nc
16
nc
17
nc
18
I1A
19
GND
20
RXA
21
TXA
22
O1-
23
ID+
24
ID-
25
GND
5
1
10
6
15
11
Pin
Function
9
I2A
10
O2-
11
I2B
12
TXM *
13
GND
14
SGND
15
RTSM *
Part Number
Connection
93A051381
Power
970101021
ID-NET Out/In
970101022
93A051386
I/O Port
970101069
ID-NET Out
970101082
ID-NET In
93ACC1884
Power
93ACC1822

Advertisement

loading

Summary of Contents for Datalogic ID-NET QL Series

  • Page 1 CONNECTIONS Reader 25P D-Sub Female Power ID-NET Out QL300 / QL500 M12 3P Male (B-coded) M12 5P Female (A-coded) Function Function Function Function Quick Link ID-NET™ Connectors Earth Shield shell, Reader Chassis both bushings DESCRIPTION RTSM * Trigger The QL series ID-NET™ connectors provide a fast and efficient way to CTSM * M12 4P Female (A-coded) cable an ID-NET™...
  • Page 2 FCC Compliance (0.2083 A x 4 readers) x [(0.058 x 2) x 6 meters] = 0.58 Vdc voltage drop Modifications or changes to this equipment without the expressed written approval of Datalogic could void the authority to use the equipment.

This manual is also suitable for:

Id-net ql300Id-net ql500