Loktronic 1710 Fitting Instructions Manual

Electromagnetic lock for indoor use

Advertisement

Quick Links

FITTING INSTRUCTIONS
LOKTRONIC ELECTROMAGNETIC LOCK
SATIN ANODISED ALUMINIUM RANGE for INDOOR USE
© Copyright LOKTRONIC March 2017
Model 1710, 550 kg Holding Force
Other Products In The Range Are:
Satin Anodised Aluminium Range
Model 1715,
approximately 275 kg holding force per leaf for pairs of outward opening doors without mullion. Low
security only. Accessories are: Header Extension Angle Brackets for extensions to the door header, 4
sizes
Model 1720,
550 kg holding force per leaf for pairs of outward opening doors without mullion. Accessories are: Model
317-611 Z/L Bracket combination for inward opening doors; Frameless Glass Door Brackets, 10mm and
12mm glass (outward opening doors only); Header Extension Angle Brackets for extensions to the door
header, 4 sizes
Polished Stainless Steel Range: Indoor Use.
Model 2010,
single unit, 750 kg holding force
Polished Stainless Steel Range: Outdoor Use (also suitable for indoor use)
Model 160,
Slimline outdoor electromagnet lock, top fixed, 300 kg holding force, weather sealed in stainless steel
housing
Model FFC
Outdoor electromagnetic lock, face fixed, 550 kg holding force, weather sealed in stainless steel housing.
Model 1800
Slimline outdoor electromagnetic lock, top fixed, 550 kg holding force, weather sealed in stainless steel
housing
1
General Description
The Model 1710 lock is a single electromagnetic lock for surface mount applications on single outward-opening doors. The
electromagnet assembly mounts securely to the header on the inside (stop side) of the door, and an armature is secured to
the door with appropriate hardware to ensure proper floating action. Figures 1 and 5 give diagrammatic explanations of typical
installations.
For inward opening doors use Model 317-611 Z/L bracket combination. For frameless glass doors opening outward use
Frameless Glass Door Bracket part no. 317-650 for 10mm glass or part no. 317-651 for 12mm glass. For extensions to a door
header use a LOKTRONIC Header Extension Angle Bracket, see figures 8-11 page 7 of these instructions.
In installations with 67 mm reveal or more no filler plate or angle bracket will be required. If reveal is less than 67 mm a filler
plate (by others) or a LOKTRONIC Header Extension Angle Bracket may need to be fitted (see Figures 5 & 6, 8-11). Included
with the 1710 lock is a fitting kit, which contains the necessary mounting hardware for standard installations with either metal
or wooden headers, without filler plates, angle brackets or reinforcing plates.
Model 1710 is supplied with a Door Position Switch (DPS), and a Magnetic Bond Sensor (MBS) as standard features. The
purpose and operation of these is explained in Sections 3.2 and 3.3 respectively.
The electromagnet is electroless nickel plated prior to potting thus minimising corrosion and providing a high quality finish.
Armatures are electroless nickel plated. The electromagnet housings are of satin-polished natural anodised aluminium. Bright
Gold and Matt Black anodised finishes are also available to order. Other special finishes may be specified: - contact sales
office for details. Accessories are not available ex-stock in Bright Gold or Matt Black.
The fitting kit is of all stainless steel components to minimise corrosion. The shoulder bolt has an extra small Allen socket to
reduce the chance of tampering. The sex nut is through-hardened, polished stainless steel for added security.
2
Mounting
Electromagnetic locks require careful alignment and accuracy in installation to ensure optimum performance. Template
dimensions are supplied on applicable drawings for location, but it will usually be easier and more accurate to follow the
recommended mounting procedures below.
Tools required:
No. 2 Pozi screwdriver; 4 mm Allen key; 8 & 13 mm drills (common)
4.2 & 6.8 mm drills; M5 X 0.8 and/or M8 X 1.25 taps (metal door/header);
2.1
Reinforcing plate (by others)
If the header is not strong enough to withstand the holding force of the electromagnet a reinforcing plate or bracket may be
required. This may need to be longer and or wider than the lock assembly to give adequate strength. The lock can then be
fitted directly to this reinforcer. See Figures 5 & 6.
1

Advertisement

loading

Summary of Contents for Loktronic 1710

  • Page 1 In installations with 67 mm reveal or more no filler plate or angle bracket will be required. If reveal is less than 67 mm a filler plate (by others) or a LOKTRONIC Header Extension Angle Bracket may need to be fitted (see Figures 5 & 6, 8-11). Included with the 1710 lock is a fitting kit, which contains the necessary mounting hardware for standard installations with either metal or wooden headers, without filler plates, angle brackets or reinforcing plates.
  • Page 2 Header Extension Angle Bracket (HEAB) 4 standard LOKTRONIC sizes available If the header is not wide enough and a filler plate cannot be fitted a LOKTRONIC Header Extension Angle Bracket may need to be fitted as shown in Figures 8-11. To fit the Angle Bracket, first locate it on either the far left or right of the header (depending on door handing), flush with the underside of the header, and mark the location of the Angle Bracket ends.
  • Page 3 Magnetic Bond Sensor (MBS) End to End Unless ordered otherwise an MBS is fitted as standard on 1710 locks. The MBS unit is mounted in the back of the electromagnet and provides an electrical signal, which indicates whether the armature is magnetically bonded to the electromagnet.
  • Page 4 LOKTRONIC ELECTROMAGNETIC LOCK SATIN ANODISED ALUMINIUM RANGE for INDOOR USE © Copyright LOKTRONIC March 2017 Model 1710, 550 kg Holding Force the armature is misaligned, OR there is debris between the mating faces, then there will be a closed circuit between the Blue/White and Orange wires, and an open circuit between the Blue/White and Brown wires, as in Figure 14 (b).
  • Page 5 Unit 7 19 Edwin Street Mt Eden Auckland P O Box 8329 Symonds Street Auckland 1150 Ph:64 9 623 3919 mail@loktronic.co.nz www.loktronic.co.nz...
  • Page 6 Unit 7 19 Edwin Street Mt Eden Auckland P O Box 8329 Symonds Street Auckland 1150 Ph:64 9 623 3919 mail@loktronic.co.nz www.loktronic.co.nz...
  • Page 7 Unit 7 19 Edwin Street Mt Eden Auckland P O Box 8329 Symonds Street Auckland 1150 Ph:64 9 623 3919 mail@loktronic.co.nz www.loktronic.co.nz...
  • Page 8 BLUE/WHITE BLUE/WHITE Unit 7 19 Edwin Street Mt Eden Auckland P O Box 8329 Symonds Street Auckland 1150 Ph:64 9 623 3919 mail@loktronic.co.nz www.loktronic.co.nz...

This manual is also suitable for:

1800