Synatel ROTASLIP MK3 Operating Instructions

Iecex & atex approved, self contained underspeed monitor

Advertisement

Quick Links

Specifi cation - PU1TZAI:
Supply:
24-240v ac/dc.
Supply Rating:
2VA.
Output:
FET
Switching Capacity:
100mA max.
Saturation Voltage:
5.5 volts max (output on).
Ambient Temp:
-15°C to +50°C.
Output State:
Normally closed (Volt drop 5.5 volts
max) above set speed. Normally
open (leakage current 1.0mA max).
Calibration:
Automatic. Initiated by magnet
supplied.
Sensing Range:
Nominally 8mm on ferrous metal at
25°C.
Input Pulse Range:
10 to 3600 p.p.m.
Repeat Accuracy:
1%.
Start Up Delay:
Adjustable to 0 - 30 seconds.
Operation Setting:
Automatic calibration by applying
magnet to 'Cal' point. Relay de-
energises at 20% under set speed .
Enclosure:
Moulded Nylon. DIN threaded 30mm
by 1.5mm pitch.
Protection:
IP66.
Relative Humidity:
90% RH.
LED Indication:
Target Detected (Sense) & Output.
Cable (Std. length):
3 metres 2 core 600/1000V (or as order).
Specifi cation - PU1TRAI:
Supply:
15-240V dc or 24-240V ac.
Supply Rating:
2VA.
Output:
S.P.C.O. Relay
Switching Capacity:
3A 60V non-inductive maximum.
Ambeint Temp:
-15°C to +50°C.
Output State:
Normally open. Closed above set
speed.
Calibration:
Automatic. Initiated by magnet
supplied.
Sensing Range:
Nominally 8mm on ferrous metal at
25°C.
Input Pulse Range:
10 to 3600 p.p.m.
Repeat Accuracy:
1%.
Start Up Delay:
Adjustable to 0 - 30 seconds.
Operation Setting:
Automatic calibration by applying
magnet to 'Cal' point. Relay de-
energises at 20% under set speed .
Enclosure:
Moulded Nylon. DIN threaded 30mm
by 1.5mm pitch.
Protection:
IP66.
Relative Humidity:
90% RH.
LED Indication:
Target Detected (Sense) & Output.
Cable (Std. length):
3 metres 5 core 600/1000V (or as order).
The equipment is covered by a 12 months guarantee from the date of shipment.
Any faults arising due to faulty materials or workmanship, within the guarantee
period, will be corrected free of charge providing the equipment is returned to us
carriage paid.
Provided that the equipment covered by these instructions is installed and oper-
ated as directed, it presents no hazard and conforms fully to health and safety
regulations.

DECLARATION OF CONFORMITY

DOC2015007A
We, the undersigned, on behalf of Synatel Instrumentation Limited, hereby
declare the products listed below conform to the relevant provisions of the
legislation, as well as pertinent clauses of the standards and other normative
documents mentioned herein.
EQUIPMENT DESCRIPTION: 30 MM AI SERIES OF PROXIMITY SWITCHES
PRODUCT NAMES:
IDE1TXXAI,PU1TXXAI,CXXTXXAI
ATEX DIRECTIVE
94/9/EC
CERTIFICATE No:
Baseefa12ATEX0226X
ISSUED BY:
SGS Baseefa, Staden Lane, Buxton,
Derbyshire, SK17 9RZ
NOTIFIED BODY NO:
1180
CATEGORIES:
1G Ex ma IIC T5 Ga
1D Ex ma IIIC T100°C Da
Tamb -15°C to 50°C, IP66
BS EN 60079- 0 :2012
Explosive Atmospheres- General requirements
BS EN 60079-18 :2009
Equipment protection by encapsulation 'm'

SPECIFIC CONDITIONS OF USE

1.
The supply circuit shall be protected by a suitably rated fuse capable of
interrupting a short circuit current of 1500 Amps.
2.
The external connections shall meet the requirements for EPL Ga in
accordance with EN 60079-26 and EPL Da in accordance with
EN 60079-31.
3.
Warning: Potential static ignition risk, clean only with a damp cloth.
4.
The integral cable shall be terminated in a suitably certifi ed enclosure or
in the safe area.
LOW VOLTAGE DIRECTIVE 2006/95/EC
BS EN 61010-1
:2010
General safety requirements for electrical
equipment
BS EN60332-1-1 :2004
Single cable fl ame propagation test
EMC DIRECTIVE 2004/108/EC
BS EN 61000-6-3 :2007
Electromagnetic Compatibility - General Emission
Standard
BS EN 61000-6-1 :2007
Electromagnetic Compatibility - General Immunity
Standard
RESTRICTION OF HAZARDOUS SUBSTANCES
(RoHS2) DIRECTIVE 2012(65)EU
No required or relevant standards are applicable
NAME: R.ASHBY
POSITION: GENERAL MANAGER
SIGNED:
ISSUE DATE : 20th May 2015
ROTASLIP MK3
Type PU1TZAI & PU1TRAI
IECEx & ATEX APPROVED,
SELF CONTAINED
UNDERSPEED MONITOR
Manual No: 2570
OPERATING INSTRUCTIONS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ROTASLIP MK3 and is the answer not in the manual?

Questions and answers

Summary of Contents for Synatel ROTASLIP MK3

  • Page 1 Calibration: Automatic. Initiated by magnet DOC2015007A supplied. We, the undersigned, on behalf of Synatel Instrumentation Limited, hereby declare the products listed below conform to the relevant provisions of the Sensing Range: Nominally 8mm on ferrous metal at legislation, as well as pertinent clauses of the standards and other normative 25°C.
  • Page 2 Introduction: Dimensions (in mm): Commissioning & Auto-calibration The ROTASLIP series is designed to detect slippage or stoppage Two LED's are provided for information purposes, on the on elevators, conveyors, fans etc. The units require no connection . The input LED fl ashes everytime a target passes the ROTASLIP with the shaft, have no moving parts and a virtually unlimited life.

This manual is also suitable for:

Pu1tzai& pu1trai

Table of Contents