Download Print this page
DABIR MP Surface Installation Manual

DABIR MP Surface Installation Manual

Advertisement

Quick Links

Surface Installation Guide (D2 Models Only)
Important Before You Start: THIS IS A "QUICK SET-UP" GUIDE ONLY
Please refer to the Dabir Operation / Service Technical Manual for full set-up and usage instructions. Failure to carefully read and
follow all instructions and safety information may result in decreased product performance or injury.
Surface Installation
1. Place Dabir Surface onto flat mattress with "THIS SIDE UP" facing up (gray side down) and secure optional corner straps when
applicable. (Surface should lay flat when properly installed.) Hose exit orientation is optional depending on the desired set-up.
2. Place facility supplied linen and incontinence pad(s) over the top of the Dabir Surface and tuck edges underneath the mattress.
Avoid wrinkles whenever possible to optimize Dabir performance and patient comfort.
Dabir Surface
(Gray Side Down)
STEPS 1 & 2: Bed Installation
System Installation - Surface Connections
3. Insert Surface connector as shown.
4. Listen for an insertion "CLICK" to confirm proper connection.
NOTE: Therapy will start automatically if powered "ON".
WARNINGS / CAUTIONS:
Surfaces are intended to be used ABOVE an underlying bed mattress
with good pressure redistribution properties over the full patient contact area.
Always place the Surface ABOVE the mattress and cover it with a bed linen.
Surfaces are NOT intended to be used in direct contact with the patient's skin.
It is the responsibility of the user to secure and protect against patient movement and/or falls.
Therapy is NOT provided unless the Controller is powered "ON" and the Surface is actively cycling.
To avoid depressurization noise, do NOT unplug Surface connector while System is activated.
It is the responsibility of the user to properly clean and disinfect the System prior to patient use.
Corporate Headquarters, Sales & Manufacturing:
Dabir Surfaces, Inc., 7447 West Wilson Ave., Harwood Heights, IL 60706, USA, www.dabir-surfaces.com
Sales Inquiries:
sales@dabir-surfaces.com, Tel: +1(888)559-3641
Technical Support:
support@dabir-surfaces.com, Tel: +1(888)559-3642
DOC# R02-0006-00054-CA
Bed Installation Diagram
Surface
Connector
STEPS 3 & 4: Connector Insertion
1
Incontinence Pad
Linen or Fitted Sheet
Dabir Surface
(Gray side down)
Mattress with good pressure
redistribution properties
®

Advertisement

loading

Summary of Contents for DABIR MP Surface

  • Page 1 Surface Installation 1. Place Dabir Surface onto flat mattress with “THIS SIDE UP” facing up (gray side down) and secure optional corner straps when applicable. (Surface should lay flat when properly installed.) Hose exit orientation is optional depending on the desired set-up.
  • Page 2 Cleaning / Disinfecting Procedures Cleaning procedures listed below are recommended by Dabir and should be adjusted according to specific healthcare facility policy. Aggressive cleaning measures may cause damage. NOTE: It is the responsibility of the user to replace Surfaces when needed.

This manual is also suitable for:

D2-3s3384-05-1lD2-3s3384-10-1lD2-3s3384-16-1lD2-3s2665-05-0lD2-3s2665-10-0lD2-3s2665-16-0l ... Show all