Download Print this page

LITEWAY Luxlink OS-3141 Operating Instructions

Optical bypass switch

Advertisement

Quick Links

WARRANTY
All fiber optic transmission systems, products and accessories
manufactured by Liteway, Inc. and it's subsidiaries are fully tested
prior to shipment and are warranted against defective materials
and workmanship for a period of five full years from the date of the
original shipment. Should a problem occur, a Return Material
Authorization Number (RMA) must be obtained from Liteway Inc.
at (516) 931-2800 and the item returned to Liteway, Inc. 166
Haverford Road, Hicksville, NY 11801, USA, prepaid. Liteway Inc.
will then, at its option repair or replace the defective item.
Liteway, Inc. maximum liability under this warranty is limited to the
cost of the defective item only. No contingent liabilities of any kind
are either assumed or implied.
Any items returned to Liteway, Inc. that have been misused,
abused, damaged, modified, connected or adjusted in any way
contrary to the instructions furnished by Liteway, Inc. or repaired
by unauthorized personnel will not be covered by this warranty.
Any non-warranty repairs required will be quoted at the current
rate for such services.
!
Important Notices
CAUTION !
AVOID DIRECT EXPOSURE TO BEAM.
All –5, -7, -8, and -9 Models use laser diodes. These solid-state
laser diodes are located in the optical ports of these units. Laser
diodes produce invisible radiation that may be harmful to human
eyes. Never look directly into the optical port of any fiber optic
unit designed to operate with single-mode optical fiber.
NOT FOR LIFE SUPPORT SYSTEMS
Liteway, Inc. does not authorize or warrant any of its products or
accessories for use in critical life support systems or applications
of any kind.
© Copyright 2017 Liteway, Inc.
135263 Rev K
OPERATING INSTRUCTIONS
®
LuxLink
Optical Bypass Switch
Single Channel Models
OS-3141, OS-2141
Dual Channel Models
OS-3241, OS-2241
The OS-3141 and OS-2141 are four pole fiber optic switch that
can be remotely controlled. The optical path through the units
is purely optical and bi-directional, there is no optical-to-
electrical-to-optical conversion. As a result there is no electrical
loss or electrical bandwidth limit on the fiber optic path. The
optical path can be select via a front panel switch or via rear
panel contact closure or TTL level inputs. The OS-3141 and OS-
2141 are non-latching switches. The OS-2141 and OS-2241 are
latching switches.
Technical Specifications
Switching Time
Back Reflection
Insertion Loss
Cross-talk
Mechanical Life
Electrical/Signal Connector
Temperature Range
Operating Power Requirements
Physical Size (mm) single
Physical Size (mm) dual
Models, wavelength, connector
-2 = 850/1310nm Multimode LC/PC
-5 = 850/1310nm Single-mode SC/PC
-6 = 1310nm Single-mode LC/PC
Specifications are subject to change without prior notice.
< 10 ms
< -30 dB
< 1.5 dB
< -50 dB
> 1 Million cycles
5 pin removable terminal block
-20º to +70ºC
11 to 60 VDC @300 mA
5.0"(127)L x 1.0" (25.4)W x 4.0"(101.6)D
5.0"(127)L x 2.2" (56.6)W x 4.0"(101.6)D
-3 = 850/1310nm Multimode ST/PC
-4 = 850/1310nm Multimode SC/PC
-7 = 1310/1550nm Single-mode FC/PC

Advertisement

loading

Summary of Contents for LITEWAY Luxlink OS-3141

  • Page 1 NOT FOR LIFE SUPPORT SYSTEMS -2 = 850/1310nm Multimode LC/PC -3 = 850/1310nm Multimode ST/PC Liteway, Inc. does not authorize or warrant any of its products or -5 = 850/1310nm Single-mode SC/PC -4 = 850/1310nm Multimode SC/PC accessories for use in critical life support systems or applications...
  • Page 2 Installation Instructions Signal Terminal Block Connections Note pin 3 is Common and/or Ground Common applications for this device are optical routing, system Pin 1 = Data/Contact Pin 2 = Data/Contact bypass, ring network restoration, and loop-back testing. Input C Input C' Pin 4 = Data Output C Pin 5 = Data Output C' The diagram below shows the basic optical functions of the OS-3141.

This manual is also suitable for:

Luxlink os-2141Luxlink os-3241Luxlink os-2241