Download Print this page
PA VB 200 Quick Start Manual

PA VB 200 Quick Start Manual

Unloader valve

Advertisement

Quick Links

VB 200/280
Pressure regulating unloader valve. At gun closure the water flow is discharged in bypass, lowering the
pressure in the circuit upstream of the valve.
Technical specifications
Construction material
Rated temperature (1)
Part number
Rated
pressure
bar
Psi
4050
60.4300.00
280
The valve has been designed for a continuous use at a water temperature of 60° C. It can resist for sho rt periods
1)
at a maximum temperature of 90°
2)
When the valve is in bypass mode, this is the decrease of pressure that has to occur in the circuit downstream
of the valve, in order that the valve can restore the working pressure in the system. The indicated figure is
expressed as a percentage of the pressure setting (working pressure).
At gun closure, a pressure increase occurs in the circuit downstream of the valve. This pressure increase is used to
activate the valve and discharge all the flow in bypass. The value of the pressure increase can not be calculated. It
depends on the correct setting of the valve (see PRESSURE ADJUSTMENT/SETTING) and on the layout of the system:
flow rate, working pressure, length and characteristic of the tubes, closing time of the gun.
Unloader valve
60.4300.00 VB 200/280
o
o
o
o
Permissible
Minimum
pressure
adjustable
pressure
bar
Psi
bar
4500
310
28
High flow rate
Brass body and Sst internal parts
Adjustable with screw and counternut to secure the working
pressure
Slots for screw fastening
Brass body and Sst internal parts
90° C (195° F)
% decrease of
pressure to
reset working
pressure (2)
Psi
%
410
22
Ultimo aggiornamento: 14/02/11
Technical manual: E 269
Max. Flow Rate
Weight
l/min
USGpm
g
53
200
3440
DN 25
1"G
FF
Inlet
Outlet
Bypass
lbs
7.6
G 1" F
1

Advertisement

loading

Summary of Contents for PA VB 200

  • Page 1 Pressure regulating unloader valve. At gun closure the water flow is discharged in bypass, lowering the pressure in the circuit upstream of the valve. DN 25 • 60.4300.00 VB 200/280 1”G High flow rate Brass body and Sst internal parts...
  • Page 2 This product is intended to be incorporated on a finished machine. This product is to be utilized with clean fresh water, even slightly additivated with normal detergents. For use involving different or corrosive liquids, contact the PA Technical department. Appropriate filtration should be installed when using impure liquids.
  • Page 3 STANDARD: every 400 working hours, check and lubricate the seals with water resistant grease. SPECIAL: every 800 working hours, control the wear of the seals and internal parts and if necessary, replace with original PA parts taking care, during installation, to lubricate with water resistant grease.
  • Page 4 P.A. SpA EQUIPAGGIAMENTI TECNICI DEL LAVAGGIO Via Milano, 13 42048 Rubiera - (RE) ITALY Tel +39 0522 623611 (ric aut) - Fax +39 0522 629600 Info@pa-etl.it - www.pa-etl.it...

This manual is also suitable for:

Vb 280