Installation Instructions
203147 / 203148 Edge II Rimless Wall Faced Toilet Suite w/ Slim or STD Seat
Important Information
This Product is to be installed by a licensed plumber, installation must comply with AS/NZS 3500 and relevant plumbing codes.
Isolating stop taps are recommended to be fitted to the hot and cold inlet connections. Please leave this document with the Product
after installation. Please ensure that the lines are flushed prior to installation as contaminates in the water can damage O-rings and
valves and will affect the performance of the Product.
Before installation, remove Product from packaging and check the Product matches what you have ordered, is complete with all parts
(per exploded drawing) and is not damaged. If the Product is incorrect, damaged or missing parts DO NOT install and return to store
with proof of purchase for a refund or replacement. Installed Products are warranted for genuine manufacturing defects arising in your
Product during the course of normal domestic or equivalent commercial use for the term of the warranty period. Our manufacturer's
warranty does not cover Product which are incorrect or have been installed with pre-existing damage or missing parts.
Pressure & Temperatures
- Maximum Hydrostatic Pressure - 500kPa. (per AS/NZS3500.1 (Clause 3.3.4) which states "The maximum static pressure at any outlet,
other than a fire service outlet, within a building shall not exceed 500kPa." NB. Pressures above 500kPa can cause damage from water
hammer, reduced life of appliances, taps and fittings, and cause excessive noise in the system.
- Minimum Hydrostatic Pressure - 100kPa. This Product may not be suitable for use with a gravity fed water supply or with continuous
flow or instantaneous hot water systems.
- Maximum operating temperature - 65°c.
Installation Instructions - Page 1
NB. These installation instructions are to be used in conjunction with the Byron Inwall Cistern installation instructions.
1. Pan Installation - mark the centre line of the pan connector on the floor for 'S' trap installation or on the wall for 'P' trap installation.
2. Place the pan into position, centralising the pan with your centre line, then draw around the pan base and mark the entry points on
the floor to where the floor fixing holes are located on the side of the pan.
3. Remove the pan and drill and screw the floor fixing brackets into place. Set the floor fixing brackets 20mm inside the line drawn
around the base of the pan. Use suitable floor fixing screws / anchors to suit the floor material. NB. The pan must be on a level surface
that is square with the wall. If the floor slopes away, the pan will need to be levelled using suitable floor chocks around the pan which
will support and stabilise the pan. The standard variance bend (133601) supplied has a set out of 90 to 105mm. The optional variance
bend (136002) has a set out of 150 to 165mm and is available for purchase separately. DO NOT BED THE PAN IN PLACE
CEMENT, CONCRETE OR SIMILAR MATERIAL.
4a. 'S' trap installation - place the variance bend into the floor outlet, from the floor to the centre of the pan outlet is 185mm, ensure the
variance bend is straight and square to the wall, assemble the variance bend wall brace and fix to the finished wall. Measure the
distance from the back edge of the pan to the start of the 'P' trap and add on sufficient length for the variance bend collar to fully
engage the 'P' trap. Remove the locking ring and rubber boot from the variance bend. Measure out from the finished wall to the
measurement you have predetermined and cut the excess off the variance bend. The distance between each ridge on the variance
bend is 10mm. Once the excess has been cut off the variance bend reassemble the rubber boot and locking ring. Use the supplied
variance bend wall bracket, with appropriate screws or anchors for the wall material, to fix the variance bend to the wall and to reduce
the risk of misalignment.
5. Slide the pan into place, being careful that full engagement of the pan 'P' trap and variance bend has been achieved.
NB. pre-soaping the rubber boot on the variance bend will assist with easier engagement onto the pan 'P' trap.
6. Once the pan is in place and connected to the variance bend, screw the pan in place using the supplied fixing screws and cover. DO
NOT OVER TIGHTEN SCREWS AS THIS MAY CAUSE THE PAN TO CRACK. Run a bead of plumbing grade silicone around the pan and
up the edge of the wall to finish off.
7. 'P' trap installation - The distance from the back edge of the pan to the start of the 'P' trap is 130mm (due to shrinkage variations
please measure the distance on the pan to confirm} taking into account full engagement of the pan collar on the 'P' trap. Install waste
pipe as per Australian standards and local authority requirements. The distance from the floor to the centre of the 'P' trap is 185mm, set
your waste pipe height accordingly. DO NOT USE OFFSET PAN COLLARS ON 'S' OR 'P' TRAP INSTALLATIONS AS THIS WILL
COMPROMISE WASTE DISCHARGE.
Contact Details
Tradelink Pty Ltd
ABN:29000003832
Raymor Customer Care
Ph: 1800 729 667
1051 Nudgee Road Banyo QLD 4014
customercare@raymor.com.au
USING

Advertisement

loading

Summary of Contents for Raymor Edge II 203147

  • Page 1 DO NOT USE OFFSET PAN COLLARS ON 'S' OR 'P' TRAP INSTALLATIONS AS THIS WILL COMPROMISE WASTE DISCHARGE. Contact Details Tradelink Pty Ltd ABN:29000003832 Raymor Customer Care Ph: 1800 729 667 1051 Nudgee Road Banyo QLD 4014 customercare@raymor.com.au...
  • Page 2 Your Raymor Warranty commences from the date of purchase of your Product (or, for new buildings, on the date of handover) for the relevant period set out in Schedule A and is valid for purchases of Products made on or after the 1st March 2014. Your Raymor Warranty does not extend to the items set out in Schedule B and these items are sold with the warranty provided by If the Product has not been installed, the Product can be returned with proof of purchase to the place of purchase.

This manual is also suitable for:

Edge ii 203148Edge ii 202492Edge ii 203074Edge ii 194386Byron 136018Byron 133137 ... Show all