Ventilation fan

Advertisement

Quick Links

MODEL:
SEP120
SEPD200L2
SEP120H
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a). Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
b). Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to
prevent power from being switching on accidentally. When the service disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to the service panel.
c). Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and standards.
d). Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning
equipment to prevent backdrafting. Follow the heating equipment manufacturer's guideline and safety standards such
as those published by the National Fire Protection Association (NFPA), and the American Society for Heating,
Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
e). When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
f). Ducted fans must always be vented to the outdoors.
g). Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) - protected
branch circuit (ceiling installation only).
h). This unit must be grounded.
i). Not for Use in Kitchens.
j). To reduce risk of fire and to properly exhaust air, be sure to duct air outside – Do not vent exhaust air into spaces
within walls or ceilings or into attics, crawl spaces, or garages
k). WARNING: To Reduce The Risk Of Fire Or Electric Shock, Do Not Use This Fan With Any Solid-State Speed
Control Device.
l). The fan must not be installed in a ceiling thermally insulated to a value greater than R40.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
2. This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up.
DO NOT MOUNT THIS PRODUCT IN A WALL.
3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off
power unit.
4. Please read specification label on product for further information and requirements.
CLEANING & MAINTENANCE
For quiet and efficient operation, long life, and attractive appearance - lower or remove grille and vacuum interior of unit
with the dusting brush attachment.
The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noi-
ses, replace the motor with the exact service motor. The impeller should also be replaced.
OPERATION
See "Connect Wiring" for details.
The fan, light, and night light can be operated separately. Use a 3-function wall control. (For models SEP120L2,
SEPD200L2,SEPD300L2)
For models SEP120H
SENSOR OPERATION
The humidity-sensing fan uses a sophisticated humidity sensor that responds to: (a) rapid to moderate (user-adjustable)
increases in humidity or (b) humidity above a user-adjustable set-point (50%-100% relative humidity). The humidity sen-
sor may occasionally turn the fan ON when environmental conditions change. If the fan continuously responds to chang-
ing environmental conditions, "H" (means "humidity") adjustment may be required. This figure is factory-set for about 75%
(Ambient temperature of 25℃).
SENSITIVITY ADJUSTMENT
The "H" has been factory set for most shower applications. However, if the fan is in a tub area or is being used for damp-
ness control, the "H" may need to be increased toward maximum "+". If the control is responding too often to changing
environmental conditions, movement toward less "-" "H" may be required.
SEP120L2
SEPD300L2
READ AND SAVE THESE INSTRUCTIONS
Installer: Leave this manual with the homeowner.
VENTILATION FAN
Cod: 0060301933

Advertisement

loading

Summary of Contents for KAZE APPLIANCES SEP120H

  • Page 1 The fan, light, and night light can be operated separately. Use a 3-function wall control. (For models SEP120L2, SEPD200L2,SEPD300L2) For models SEP120H SENSOR OPERATION The humidity-sensing fan uses a sophisticated humidity sensor that responds to: (a) rapid to moderate (user-adjustable) increases in humidity or (b) humidity above a user-adjustable set-point (50%-100% relative humidity).
  • Page 2 OPERATION To adjust the “H”: 1. Disconnect power at service entrance. 2. Through the grille, locate the slot marked “H”. 3. Carefully rotate the “H” adjustment toward “+” or “-”. 4. Turn on power and check operation by turning on the shower or other humidity source until the fan turns on. 5.
  • Page 3 PANEL NIGTH NIGTH LIGHT LIGHT SWITCH LIGHT RECEPTACLE SWITCH LINE LIGHT SWITCH BOX RECEPTACLE UNIT SWITCH BOX 120V AC LINE IN For models SEP120H BLACK(BLK) WHITE(WHT) BROWN(BRN) GROUND (GRD) HUMIDITY WIRE UNIT SENSOR PANEL HUMIDITY SENSOR HUMIDITY RECEPTACLE SENSOR SWITCH...
  • Page 4 Hanger Bar Kit Housing Wiring plate Damper / Duct Connector SEPD200L2 Power box SEPD300L2 Power box For SEP120H Screw Screw Screw Screw Washer * Blower Assembly includes part 5,6,7,8,b,c,e Ensure that the fan is switched off from the supply WARNING: mains before replacing.