Unite 7885653303 User Manual

Smoke detector 230 v

Advertisement

Quick Links

1. DESCRIPTION
All Unite smoke detectors are approved to the most recent and rigorous stand-
ards. The photoelectric smoke detectors with their unique X-Profile sensing
chamber are approved to EN14604: 2005 and are particularly sensitive to
slow smouldering fires typically originating in living rooms, bedrooms and
hallways whilst being highly resistant to nuisance alarms.
The alarms are guaranteed for 6 years. However, their lives can be significant-
ly reduced by adverse environments, incorrect location and a failure to regu-
larly clean and maintain them according to the following instructions. Incorrect
location and a lack of reasonable care may also cause them to malfunction
and will invalidate the warranty.
Product Features
• All models are supplied with a back-up power source. The 7885653316
has a longlife lithium battery and the 7885653303 has 3 x AAA replace-
able alkaline batteries.
• Alarm Silence – Silence your smoke alarm by momentarily pressing the
test button. Ideal in non-emergency situations when nuisance alarms may
have been created, for example, by steam. The red light flashes every 8
seconds to remind you that the smoke alarm has been silenced and will
automatically reset to quiescent mode in 10 minutes.
• Bespoke software maximizes detection ability and false alarm rejection.
• Power automatically switched on as detector is installed onto its mounting
plate and automatically switched off when detector is removed.
• A permanent green LED indicates mains power is connected and switched
on.
• Red LED flashes approximately every minute confirming unit is receiving
power and ready to detect fire conditions. (Quiescent Mode)
• Low Battery Warning alarm gives one acoustic alarm every minute.
• Low Battery Warning Silence – Low battery warnings often start at night.
Silence the audible warning for ten hours by pressing the test button, thus
avoiding removing the alarm from its mounting plate and turning it off. The
batteries on non-rechargeable battery alarms can then be replaced when
convenient the following day.
• Extra Large Test Button for ease of use, tests sensitivity, circuitry, power
supply and alarm sounder.
• Loud 85 Decibel Piezo Electric alarm automatically resets when hazardous
condition has passed and chamber is clear.
• Easy Installation – fixing screws and plugs supplied.
• The built in interconnect facility allows the connection of a combination
of up to 15 smoke detectors together so that when one alarm sounds all
connected alarms will sound.
2. CHOICE AND LOCATION
Optical Smoke detectors are best at detecting smouldering fires such as those
started in electrical equipment, clothing and soft furnishings such as seating,
bedding, curtains and carpets. They are, therefore, ideally suited for living
rooms, bedrooms and escape routes in domestic accommodation.
For minimum protection, install at least one smoke alarm on each level of your
home. They should be installed in hallways, corridors and all escape routes
from the building and within 3 meters of all bedroom doors. All alarms should
be interconnected.
Recommended siting of smoke detectors in:
Single storey
home with one
sleeping area
DINING
KITCHEN
ROOM
LIVING ROOM
Single storey
home with two
sleeping areas
Multiple storey
home with multiple
sleeping areas
SOVEVÆRELSE
Smoke detectors for minimum protection
SOVEVÆRELSE
Smoke detectors for minimum protection
SOVEVÆR.
SOVEVÆR.
Recommended position of smoke detectors in a room, corridor or
SOVEVÆR.
SOVEVÆR.
escape route:
DAGLIGSTUE
KØKKEN
GARAGE
DAGLIGSTUE
KØKKEN
KÆLDER
KÆLDER
Recommended position of smoke detectors on apex ceilings:
3. AVOID THE FOLLOWING LOCATIONS
The life of this smoke detector can be significantly reduced by adverse envi-
ronments, incorrect location and a failure to regularly clean and maintain it in
accordance with the instructions below. Incorrect location and a lack of rea-
sonable care may also cause it to malfunction and will invalidate the warranty.
1. Do not locate near fans or extractors. These can pull smoke and heat away
from the smoke detectors.
2. Do not install smoke detectors in or near high humidity areas such as
showers, bathrooms or kitchens where humidity levels exceed 85% or the
room temperature exceeds 40°C or falls below 0°C. These conditions may
cause nuisance alarms and damage.
3. Do not install in the peak of an "A" frame or sloping ceiling. This may delay
BEDROOM
smoke and heat reaching them due to the presence of dead air.
4. Do not install less than 300mm from walls and light fittings when mounted
on the ceiling where heat and dead air may prevent smoke reaching the
alarm.
5. Do not install smoke detectors in insect infested areas.
DINING
BEDROOM
KITCHEN
ROOM
LIVING ROOM
BEDROOM
BED ROOM
BED ROOM
BED ROOM
GARAGE
LIVING ROOM
KITCHEN
BASEMENT
GARAGE
300mm MIN.
150mm MIN.
300mm MIN.
ABOVE HEIGHT OF DOORS,
WINDOWS AND VENTS
600mm
MINIMUM
6. Do not install smoke detectors in areas subjected to heavy concentra-
tions of cigarette smoke that will cause nuisance alarms and the smoke
detector to become contaminated.
7. Do not install smoke detectors in boiler rooms and garages where fumes
and dust may cause nuisance alarms.
8. Do not install near objects that could prevent smoke and heat reaching
the alarm.
9. Do not install close to fluorescent light fittings that could trigger nuisance
alarms.
10. Do not paint the alarm.
The location of the alarms must be in accordance with applicable building
regulations.
4. FURTHER DETAIL ON SMOKE DETECTOR
1. At least one smoke detector should be installed in the escape route from
all floors of the building.
2. The detection element of smoke detectors should be between 25mm and
600mm below the ceiling, or in the case of heat alarms between 25mm
and 150mm
3. Smoke and heat alarms should be at least 300mm from any wall or light
fitting.
4. If ceiling mounting is impractical smoke detectors may be installed on
walls provided that the area is no longer or wider than 10 meters and
the total area does not exceed 50 square meters and that: -
a. The smoke detector is between 150mm and 300mm below the
ceiling.
b. The bottom of the smoke detector is above openings such as vents,
doors and opening windows
c. They are not mounted close to or above heaters or air-conditioning
vents.
5. Where smoke detectors are located in a hallway, corridor or landing,
the smoke detectors should be no further than three meters from any
bedroom door to assist audibility behind closed doors.
6. For maximum protection no point should be further than 7.5 meters from
any smoke detector
7. To give the earliest warning of a developing fire, smoke detectors should
be installed in all the rooms of your home and interlinked. (other than
those in section 3, AVOID THE FOLLOWING LOCATIONS).
5. INSTALLATION PROCEDURE
IMPORTANT NOTE: Mains powered smoke detectors should be installed
by a qualified electrician and in accordance of the Building Regulations.
WARNING: Storing or installing smoke detectors in temperatures below
5°C and above 30°C, and in low humidity may cause acustic signals and
nuisance alarms when first installed. These will clear after a short time when
the smoke detector has become acclimatised. Extended periods under these
conditions will reduce the life of the alarms and invalidate the warranty.
Do not expose to dripping or splashing. Disconnect the alarm before
dismantling. Interconnect terminals and circuits are not to be accessible and
must only ever run to other Interconnect terminals. Do not interconnect to
alarms with other brand-names or made by other manufacturers.
The power supply should be from one of two sources:
a. An independent circuit at the dwellings main distribution board with no
other electrical equipment connected (other than a dedicated supply
failure monitoring device) or:
b. A separately electrically protected and regularly used local lighting
circuit. Only suitably approved cabling should be used. The alarms
should be wired using a minimum of 1,5mm2 "3 core and earth" cable;
with the Brown to Live (L), Grey to neutral (N) and the Black to Interlink
(I). All alarm circuits should be protected by an over-current device. The
maximum total length of wiring should not exceed 250m.

Advertisement

loading

Summary of Contents for Unite 7885653303

  • Page 1 4. FURTHER DETAIL ON SMOKE DETECTOR Product Features BED ROOM BED ROOM • All models are supplied with a back-up power source. The 7885653316 has a longlife lithium battery and the 7885653303 has 3 x AAA replace- GARAGE able alkaline batteries. LIVING ROOM KITCHEN 1.
  • Page 2 Remove this cover when using mini-trunking Replacing batteries (7885653303 only) To replace the batteries on the 7885653303 version, isolate mains power to 5. Test the smoke detector using the large test button (shown above) without the smoke detector, release the retaining clips, lower the smoke detector on its mains power and check it sounds at least 3 times and that the red LED hinge and refer to Fig.