INTRODUCTION
1.
Please read instructions before using this appliance.
2.
When using this appliance, basic precautions should always be followed to reduce the risk of fire, electric shock and injury.
3.
Clean machine thoroughly before and after all uses following cleaning instructions below.
ELECTRICAL REQUIREMENTS
1.
Wire warmer into a grounded circuit with correct voltage and sufficient power capacity. Refer to the product label (serial plate)
on the warmer for voltage and wattage requirements.
2.
All electrical connections must be made according to local codes by a licensed electrician.
SAFETY INSTRUCTIONS
1.
Warning! All power must be disconnected at power source before any service procedure is performed.
2.
This appliance is hot when in use. To avoid burns, do not let bare skin touch hot surfaces. Keep combustible materials, such as
drapes and other furnishings, away from appliance.
3.
Extreme caution is necessary when any appliance is used by or near children and whenever the appliance is left unattended.
4.
Always turn the power off at the circuit breaker before cleaning, adjusting or maintaining this machine.
5.
Do not operate any appliance after it malfunctions, has been dropped, or damaged. Return appliance to an authorized service
facility for examination, electrical or mechanical adjustment, or repair.
6.
Do not use outdoors. This appliance is not intended for use in wet or moist locations. Never locate appliance where it may fall
into water.
7.
To prevent a possible fire, it is recommended that the unit is installed above a non-combustible surface.
This appliance has electrical parts. Do not use it in areas where gasoline, paint, or flammable liquids are used or stored.
8.
INSTALLATION
1.
All 6155 models should be wired per ELECTRICAL REQUIREMENTS above.
2.
Use MOUNTING BRACKET supplied with the warmer. Install with the following clearances: 9" min. between end of unit and
any wall, 12" min. between side of unit and any wall, 16" min. between bottom of unit and counter, and 1 7/8" min. between
top of unit and overhead surface.
3.
This unit radiates heat when in use therefore we recommend that the unit be installed above a non-combustible surface.
4.
A wire leg stand (part number 66099) is available for counter use.
5.
Use Only Copper Wire suitable for 90° C (194° F).
6.
If warmer fails to work properly when first operated call NEMCO customer service at 1-800-782-6761.
OPERATION
1.
Place food products in a pan located directly under the warmer for best results.
2.
Turn warmer off when not in use.
CLEANING
NOTE: Proper maintenance plays an important part in the life span and functioning of the warmer.
1.
Turn warmer off before cleaning.
2.
Do not immerse in water or other liquid. Avoid splashing water into unit.
3.
The housing and reflectors are made of anodized aluminum and aluminized steel, which can be kept clean by use of a damp
sponge and soap solution.
TROUBLESHOOTING
No Heat
Unit Blows Fuse or Circuit Breaker
All manuals and user guides at all-guides.com
Operating and Maintenance Instructions
Model series
6155-24 6155-36 6155-48 6155-60 6155-72
6155-24-SL, 6155-36-SL, 6155-48-SL, 6155-60-SL, 6155-72-SL
6155-24-D, 6155-36-D, 6155-48-D, 6155-60-D, 6155-72-D
ALTERNATE VOLTAGES: 208V/240V
Check that power switch is turned "ON".
Check power at heater.
Check to make sure circuit is not overloaded.
1

Advertisement

loading

Summary of Contents for Nemco 6155-24

  • Page 1 A wire leg stand (part number 66099) is available for counter use. Use Only Copper Wire suitable for 90° C (194° F). If warmer fails to work properly when first operated call NEMCO customer service at 1-800-782-6761. OPERATION Place food products in a pan located directly under the warmer for best results.
  • Page 2: Specifications

    1080 6155-36-DL 1780 6155-36-DL-208 1780 6155-36-DL-240 1780 6155-48-DL-208 2320 6155-48-DL-240 2320 6155-60-DL-208 2960 6155-60-DL-240 2960 6155-72-DL-208 3610 6155-72-DL-240 3610 301 Meuse Argonne, Hicksville, OH 43526 NEMCO FOOD EQUIPMENT Phone: (419) 542-7751 Fax: (419) 542-6690 Toll free: 1-800-782-6761 www.nemcofoodequip.com 45818-R 2-5-2021...
  • Page 3 All manuals and user guides at all-guides.com 301 Meuse Argonne, Hicksville, OH 43526 NEMCO FOOD EQUIPMENT Phone: (419) 542-7751 Fax: (419) 542-6690 Toll free: 1-800-782-6761 www.nemcofoodequip.com 45818-R 2-5-2021...
  • Page 4 LIGHTED MODELS, THE LIGHT BULBS ARE 120V. A BRANCH CIRCUIT IS PROVIDED. PLEASE KEEP WHITE AND GREEN WIRES CONNECTED AS RECEIVED. 301 Meuse Argonne, Hicksville, OH 43526 NEMCO FOOD EQUIPMENT Phone: (419) 542-7751 Fax: (419) 542-6690 Toll free: 1-800-782-6761 www.nemcofoodequip.com 45818-R...
  • Page 5 All manuals and user guides at all-guides.com SINGLE WITH TOGGLE SWITCH SINGLE WITH INFINITE CONTROL 301 Meuse Argonne, Hicksville, OH 43526 NEMCO FOOD EQUIPMENT Phone: (419) 542-7751 Fax: (419) 542-6690 Toll free: 1-800-782-6761 www.nemcofoodequip.com 45818-R 2-5-2021...
  • Page 6 All manuals and user guides at all-guides.com DUAL WITH TOGGLE CONTROL DUAL WITH INFINITE CONTROL 301 Meuse Argonne, Hicksville, OH 43526 NEMCO FOOD EQUIPMENT Phone: (419) 542-7751 Fax: (419) 542-6690 Toll free: 1-800-782-6761 www.nemcofoodequip.com 45818-R 2-5-2021...

This manual is also suitable for:

6155-24-2086155-366155-36-2086155-36-2406155-486155-48-208 ... Show all