WARNING
Warning identifies conditions and actions that pose hazards to the user.
To avoid electrical shock or personal injury, follow these guidelines:
n
Do not point laser directly at eye or indirectly off reflective surfaces.
n
Replace the batteries as soon as the empty battery indicator appears.
n
Do not operate the thermometer around explosive gas, vapour, or
dust.
n
Do not connect the optional external probe to live electrical circuits.
n
To avoid a burn hazard, remember that highly reflective objects will
result in lower than actual temperature measurements.
LASER RADIATION
DO NOT STARE INTO BEAM OR VIEW DIRECTLY
WITH OPTICAL INSTRUMENTS.
Max output: <1mW - Wavelength: 630-670nm
Class 2 laser product conforms to IEC825-1:1993.
NO
CAUTION
To avoid damaging the
thermometer or the
equipment under test protect
them from the following:
PROTECT FROM EMF
PROTECT FROM
& STATIC ELETTRICITY
THERMAL SHOCK
CE Certification
This instrument conforms to the following standards:
EN 50081-1: 1992, Electromagnetic emissions
EN 50082-1: 1992, Electromagnetic immunity
Maintenance
Changing the Battery
To remove the 9V battery, open the
battery compartment and pull the
bottom of battery
(See figure 1)
.
Extract the battery.
To install the battery, insert the
battery to the battery
compartment
with the positive side facing toward
the rear of the battery compartment.
1
Technical Specifications
Spectral band: 8-14 mm
Repeatability: ±0.5% of the reading or ±0.7°C (±1.3°F)
Display resolution: 0.1°C/°F
Response time: 500 ms @ 95% response
Emissivity: pre-set to 0.95 - Adjustable from 0.20 to 1.00 - Value
indication on display.
Laser sighting: Wavelength 650nm, Beam diameter 3mm, Laser
indicator label on display
Display: 4 ½ digit custom back lighted LCD, 2nd line 5 digit
alphanumeric, plus labels for max, min, Dif., Avg, emissivity, Hold, °C,
°F, battery level, Ext. probe.
Auto Power Off: Automatic after 30 sec of no operation.
Alarm: low and high alarm with flashing label on display and sound.
Signal processing: °C/°F, hold, max, min, Dif. (max-min), Avg.
USB serial Port +Data Memory: 64 values including date/time (not
available on PRO++ model only)
Power supply: 9V alkaline battery
Typical battery life: 40 h with laser and backlight off
Ambient operating range: 0 to 50°C (32 to 120°F) / 10-95% RH non
condensing
Storage temperature: -20 to 60°C (-4 to 150°F) without battery
Tripod mount: ¼" 20 UNC threading
Environmental rating: IP54
Dimensions: 90x135x38 mm (3.5x5.5x1.5 in)
Weight: 165 g (6 oz.) net (battery included)
MicroRay Xtreme
Optics : D:S=35:1 (26mm@900mm, 1"@35") @90% of energy
Temperature Range: -30 to 760°C (-22 to 1400°F)
Accuracy : From 0 to f.s. (32 to f.s.) ±1% of reading or ±1°C (±1.8°F)
From -30 to 0°C (-22 to 32°F) ±(0.07°C/°C +1°C) ±(0.07°F/°F +1.8°F)
MicroRay Xtreme+/Xtreme++
Optics : D:S=50:1 (18mm@900mm, 0.7"@35") @90% of energy
Temperature Range: -30 to 1000°C (-22 to 1832°F)
Accuracy : From 0 to f.s. (32 to f.s.) ±1% of reading or ±1°C (±1.8°F)
From -30 to 0°C (-22 to 32°F) ±(0.07°C/°C +1°C) ±(0.07°F/°F +1.8°F)
TTA sighting: (True Target Aiming) dot laser pinpointing (Xtreme++ only)
MicroRay PRO++/HVAC++
Optic : D:S=20:1 (50mm@1000mm, 2
s
"@40"
Temperature Range: -30 to 600°C (-22 to 1112°F)
Accuracy :
From 0 to 70°C (32 to 158°F) ±1°C (±1.8°F);
From 0 to f.s.
7
(158 to f.s.)
±1.5% of reading or ±1.5°C
From -30 to 0°C (-22 to 32°F) ±(0.07°C/°C +1°C) ±(0.07°F/°F +1.8°F)
Integrated ambient T+RH% sensor accuracy (HVAC++ only): ±2%RH ;
±0.2°C (±3.6°F)
MicroRay FOOD+/FOOD++
Optics : D:S=12:1 (50mm@600mm, 2"@24") @90% of energy
Temperature Range: -30 to 300°C (-22 to 572°F)
Accuracy: From 0 to 100°C (32 to 212°F) ±1°C (±1.8°F);
From 100 to 300°C (212 to 572°F) ±1.5% of reading;
From -30 to 0°C (-22 to 32°F) ±1.5°C (2.7°F)
Danger Zone Alarm (from 4 to 60°C)
8 hours countdown timer
MicroRay AUTO+/AUTO++
Optics : D:S=20:1 (50mm@1000mm, 2"@40") @90% of energy
Temperature Range: -30 to 760°C (-22 to 1400°F)
Accuracy : From 0 to f.s. (158 to f.s.) ±1% of reading or ±1°C (±1.8°F);
NO
From -30 to 0°C (-22 to 32°F) ±(0.07°C/°C +1°C) ±(0.07°F/°F +1.8°F)
TTA Laser sighting: (True Target Aiming) dot laser pinpointing
Flashlight: White LED (AUTO+ only)
RTD Contact Probe
(not available on AUTO+/AUTO++/HVAC++)
Input range: from -30°C to 500°C
(-22 to 932°F)
Resolution: 0.1°C
/°F
up to 199.9°C
/°F
. 1°C
/°F
Accuracy: ±0.2% of reading or ±0.2°C (±0.36°F) whichever is greater
Sensor type: Pt1000 Class A - AISI316 (not included)
Sensor accuracy: ±(0.2% rdg. +0.2°C); ±(0.2% rdg. +0.4°F)
IRLogMan 2006
Backlit
2
Laser Sight
custom LCD
Probe Jack
Battery
compartment
USB port
Tripod thread
Wrist strap
Measuring
Pull the trigger to switch the unit on. The display will show the
temperature and the laser will turn on. Move the laser pointer to the
centre of the measuring area. Read the temperature of the target. The
unit's display will remain activated (HOLD) for 30 seconds after the trigger
is released.
Important Notice
Inaccurate reading will result from measuring shiny or polished metal
surfaces. The unit cannot measure through transparent surfaces such as
glass. Steam, dust, smoke, etc. Can prevent accurate measurement by
obstructing the unit's optic. Make sure that the target is larger than the
unit's spot size.
Danger Zone Alarm
(MicroRay FOOD only)
The unit use the HI and the LO icons to display the HCCP Food Danger
Zone Alarm. The LO icon will appear if the temperature is below 4°C
(40°F); the HI icon will appear if the temperature is upper than 60°C
(140°F); The HI and LO icons will flash and the beeper will sound if the
temperature is inside the Danger Zone.
8 Hours Countdown Timer
The unit includes a programmable 8 hours countdown timer to help
monito cooking, cooling, and holding times.
Memory
All models (excluding PRO++) can store up to 64 test with date and time
using the internal real time clock. Datalogging can be manual or
automatic with settable sampling Time.
TM
The optional Windows
IRLogman 2006 (see figure 3) software includes
the USB cable. The Software allows viewing, graphing, exporting and
printing the measure. Remove the USB Port cap (see fig.2) for PC
connecting.
True Target Aiming (TTA)
These instruments have a laser sighting with a reflex system of the beam
passing through the center of the lens, which grants the best possible
accuracy when aiming at a distance.
Integrated T+RH% probe
It is possible to read the Air Temperature and Relative Umidity on the
display by selecting the external sensor function (see flow chart).
) @90% of energy
Display
(see figure 4)
1 - Battery level indicator (3 levels)
(±2.7°F)
2 - Symbol for HOLD function
3 - External probe indicator
4 - Temperature value
5 - °C / °F engineering unit
6 - Symbol for HIGH alarm
7 - Symbol for LOW alarm
8 - Emissivity value
9, 10, 11 - MIN, MAX, Avg, and Dif 2nd line
value label
12 - 2nd line value
13 - Laser on indicator
Buttons
(see figure 5, 6)
Trigger
ENT
If the trigger is pulled the unit will switch on.
The laser will turn off and the display is HOLD
when he trigger is released. However, the
backlight remains on for 5 seconds. If no
button is pressed for 30 seconds the unit will
turn off.
If in Set mode, it accepts the parameter
change.
otherwise.
MOD
Mode Button
If in measure mode, it cycles through the
display mode menu;
If in Set mode, it increase the value.
3
FUN
Function Button
If in measure mode, it cycles through the
memory manager menu;
If in Set mode, it decrease the value.
Eurotron's Warranty
Eurotron guarantees its products against defects in materials and
workmanship for 1 YEAR from the date of purchase. If the unit should
malfunction, it must be returned during the warranty period,
transportation prepaid, to any authorized Eurotron service center. Upon
examination, if the unit is found to be defective it will be repaired or
replaced at no charge. Eurotron's WARRANTY does not apply to defects
resulting from any action of the purchaser, including but not limited to
mishandling, improper interfacing, operation outside of design limits,
improper repair, or unauthorized modification. This WARRANTY is VOID if
the unit shows evidence of having been tampered with or shows evidence
of being damaged as a result of excessive corrosion; or current, heat,
moisture or vibration; improper specification; misapplication; misuse or
other operating conditions outside of Eurotron's control. This warranty
applies to the original purchaser only. Resellers are not authorized to
extend any other warranty on Eurotron's behalf. The purchaser is
responsible for shipping charges, freight, insurance and proper packaging
to prevent breakage in transit. Please include a copy of the original
invoice.
Distance
Diam. Target
(MicroRay FOOD only)
Distance
Diam. Target
Distanza
Diam. Target
(MicroRay Xtreme++/AUTO++ only)
(MicroRay HVAC++ only)
Distanza
Diam. Target
3
2
4
1
5
Distanza
13
Diam. Target
4
12
11
10
6
7
9
8
5
Distanza
Diam. Target
Trigger
Distanza
ENT
Diam. Target
6
Function button
FUN
Mode button
MOD
Distanza
Diam. Target
European Headquarter:
Eurotron Instruments SpA
Viale F.lli Casiraghi 409/413
20099 Sesto S. Giovanni (MI)
Tel. : 02 24 88 201
FAX: 02 24 40 286
Mail: info@eurotron.com
Web: www.eurotron.com
0
250
600
1000
1500
2000
mm
16
30
50
94
149
204
mm
D:S=12:1
MicroRay FOOD+
50mm@600mm
2in@24in
MicroRay FOOD++
0
9.8
24
39
59
78.7
in.
0.6
1.2
2
3.7
5.9
8
in.
0
100
500
1000
1500
3000
mm
7
11
29
50
79
164
mm
MicroRay PRO++
D:S=20:1
50mm@1m
2in@40in
0
4
19.7
40
59
78.7
in.
0.3
0.4
1.1
2
3.1
4.2
in.
0
250
500
900
1500
3000
mm
20
22
23
26
57
133
mm
MicroRay Xtreme
D:S=35:1
26mm@900mm
1in@35in
0
9.8
19.7
35
59.1
118
in.
0.8
0.9
0.9
1
2.2
5.2
in.
0
250
500
1000
1500
5000
mm
20
19
19
22
43
191
mm
D:S=50:1
MicroRay Xtreme+
18mm@900mm
MicroRay Xtreme++
0.7in@35in
0
9.8
19.7
35
59
197
in.
0.8
1.3
0.8
0.7
1.7
7.5
in.
USA Headquarter:
E Instruments Group LLC
172 Middletown Blvd - Suite B 201
Langhorne, PA 19047
Tel. : 215 750 1212
FAX: 215 750 1399
Mail: info@einstrumentsgroup.com
Web: www.einstrumentsgroup.com

Advertisement

loading

Summary of Contents for E Instruments Eurotron MicroRay Xtreme

  • Page 1 Emissivity: pre-set to 0.95 - Adjustable from 0.20 to 1.00 - Value moisture or vibration; improper specification; misapplication; misuse or unit's display will remain activated (HOLD) for 30 seconds after the trigger E Instruments Group LLC Eurotron Instruments SpA indication on display.
  • Page 2 Lo strumento utilizza i due indicatori HI e LO sul display per evidenziare la Vita batteria: 60 ore con laser e illuminazione spenta - 20 ore altrimenti Condizioni operative: 0 a 50°C / 10-95% RH non condensante temperaturadi pericolo per gli alimenti come descritto dalle HACCP. eurotron L’indicatore LO rimarrà...
  • Page 3 MM850569 ed. 01...

This manual is also suitable for:

Eurotron microray xtreme+Eurotron microray pro++Eurotron microray hvac++Eurotron microray food+Eurotron microray auto+