Installation Instruction for the Jazz
1000/1100 the 3300 the ArcticChill88/98 the
ArcticStar55 and the AquaPoint60 Water
Coolers
Caution
•
When installing a POU Cooler use only new hoses (supplied) and new compression fittings
when connecting to the mains.
•
J Guest push fit connections should be regularly checked for leakage. Over time they will
become brittle and need to be replaced.
•
If the electrical cord is damaged, it must be replaced by a competent and qualified
individual.
•
Children, and persons with reduced physical or mental capability must be instructed and
supervised on the use of the equipment.
•
Any maintenance, servicing and moving of the equipment must only be undertaken by a
qualified and trained individual.
•
It is strongly recommended that the mains water supply to the POU Cooler is turned off
over week ends and long periods of office closures.
•
Please note: Product warranty is ONLY valid if the product installation has been carried out
according to our Installation Instructions and conditions stated on our Terms and
Conditions.
Safe Usage
•
Always turn electricity off before working on the equipment
•
(POU)Always turn water off at nearest stop cook before working on the equipment
•
(Bottled Water) Remove the bottle
•
When not in use for an extended period: Turn mains water off or remove bottle. Turn
power off. Sanitise before re-commissioning.
•
Install cooler on a flat surface to avoid vibration and noise
•
Leave 15cm gap all around to provide good ventilation
•
Install away from heat source which could affect the unit's cooling capacity
•
Avoid freezing conditions which could rupture the pipes
•
Never tilt unit over 45 degrees when carrying to storing
•
Wait for an hour after transport before installing to allow coolant to settle
•
Fill water reservoir with water before unit is powered up to avoid damage to the
refrigeration and heating element
Commissioning
•
For POU Coolers follow the Plumbing & Filter Installation Instructions
•
For conversion from Bottled to POU follow the Conversion Instructions
•
Sanitise the cooler before first use and follow Sanitising Instructions
•
For "Open Tank" Coolers make sure that the water detaching board (Baffle) inside the cold-
water tank is inserted tightly. If not fixed properly, it may affect your cold-water volume
•
For POU Coolers ensure that the float, connected to the water tank lid, moves freely
•
For Direct Chill Coolers follow Direct Chill Cooler instructions
•
Before switching the power on make sure that both the cold and hot water tanks are filled
with water