Installation Instruction for the Jazz
1000/1100 the 3300 the ArcticChill88/98 the
ArcticStar55 and the AquaPoint60 Water
Coolers
Caution
When installing a POU Cooler use only new hoses (supplied) and new compression fittings
when connecting to the mains.
J Guest push fit connections should be regularly checked for leakage. Over time they will
become brittle and need to be replaced.
If the electrical cord is damaged, it must be replaced by a competent and qualified
individual.
Children, and persons with reduced physical or mental capability must be instructed and
supervised on the use of the equipment.
Any maintenance, servicing and moving of the equipment must only be undertaken by a
qualified and trained individual.
It is strongly recommended that the mains water supply to the POU Cooler is turned off
over week ends and long periods of office closures.
Please note: Product warranty is ONLY valid if the product installation has been carried out
according to our Installation Instructions and conditions stated on our Terms and
Conditions.
Safe Usage
Always turn electricity off before working on the equipment
(POU)Always turn water off at nearest stop cook before working on the equipment
(Bottled Water) Remove the bottle
When not in use for an extended period: Turn mains water off or remove bottle. Turn
power off. Sanitise before re-commissioning.
Install cooler on a flat surface to avoid vibration and noise
Leave 15cm gap all around to provide good ventilation
Install away from heat source which could affect the unit's cooling capacity
Avoid freezing conditions which could rupture the pipes
Never tilt unit over 45 degrees when carrying to storing
Wait for an hour after transport before installing to allow coolant to settle
Fill water reservoir with water before unit is powered up to avoid damage to the
refrigeration and heating element
Commissioning
For POU Coolers follow the Plumbing & Filter Installation Instructions
For conversion from Bottled to POU follow the Conversion Instructions
Sanitise the cooler before first use and follow Sanitising Instructions
For "Open Tank" Coolers make sure that the water detaching board (Baffle) inside the cold-
water tank is inserted tightly. If not fixed properly, it may affect your cold-water volume
For POU Coolers ensure that the float, connected to the water tank lid, moves freely
For Direct Chill Coolers follow Direct Chill Cooler instructions
Before switching the power on make sure that both the cold and hot water tanks are filled
with water

Advertisement

loading

Summary of Contents for AAFIRST Jazz 1000

  • Page 1 Caution • When installing a POU Cooler use only new hoses (supplied) and new compression fittings when connecting to the mains. • J Guest push fit connections should be regularly checked for leakage. Over time they will Installation Instruction for the Jazz become brittle and need to be replaced.
  • Page 2 Converting a Bottled Cooler to POU (Does not apply to Direct Chill Coolers) De-scaling a Hot & Chilled Cooler • It takes literally five minutes, using our Conversion Kit (De-scaling automatically sanitises the Boiler) • Remove Bottled Cooler top by unscrewing screws in back •...
  • Page 3: Troubleshooting

    AA Water Cooler Service, Maintenance a Recycling Information This appliance is intended to be used in household and similar applications such as: HYGIENE • Water is our most important FOOD and Water Coolers must be maintained in a • staff kitchen areas in shops, offices, and other working environments. •...
  • Page 4: Installation

    ArcticStar 55 HOT a Cold Installation instructions Quick Hot Water reference guide GREEN LIGHT: Power ON The ArcticStar 55 Hot Water & Hot Water Booster. PULSING ORANGE LIGHT : Indicates heating to standard 92C. The "standard" hot water temperature range is between 82C and 92C. It can be BOOSTED to SOLID ORANGE LIGHT : Standard temperature range of 92C/82C 95C/96C to provide 1.51tr of piping hot water for instant draw off- The hot water boosting PULSING RED LIGHT : Boosting to 95C/96C...
  • Page 5 3300/ARCTICSTAR55 PRODUCT NAME Hot & Cold and Ambient & Cold-Water Dispenser JAZZ 1000/1100 POU MODELS MODEL NAME WCPC(H)3300/55 WCPTC(H)3300/55 PRODUCT NAME Hot & Cold and Ambient & Cold-Water Dispenser DESCRIPTION Floor Standing Table Top MODEL NAME Jazz 1000 Jazz 1100...
  • Page 6 ARCTICCHILL 88 ARCTICCHILL 98 PRODUCT NAME Direct Chill Cold-Water Dispenser PRODUCT NAME Direct Chill Ambient & Cold-Water Dispenser MODEL NAME WCPC88 WCPTC 88 MODEL NAME WCPC98 EXTERNAL DIMENSIONS Floor Standing Table Top EXTERNAL DIMENSIONS Floor Standing 340(W) X 340(D) X 340(W) X 340(D) X 460(H) 340(W) X 340(D) X 1180(H) 1180(H)
  • Page 7: Product Name

    Thermostat (in Cold) COOLING TYPE Forced Cooling Type REGULATED POWER 220-240V~ / 50Hz POWER CORD LENGTH 1.8M Cedar House Grange Farm FRONT PANEL Long Lane SIDE PANEL Newbury RG14 2TF FAUCET PP Assembly PH: 44 (0) 1635 202489 E-mail: enquiries@aafirst.co.uk http://www.aafirst.co.uk...

This manual is also suitable for:

Jazz 11003300Arcticstar 55Arcticchill 88Arcticchill 98Aquapoint 60