Download Print this page

Galvin Engineering TCS9J150C Installation Manuallines

Clinilever cp-bs hospital shower set w/ medi hand shower & 900 ss grab rail

Advertisement

Quick Links

Product Installation Guidelines
CliniLever CP-BS Hospital Shower Set w/ Medi Hand
Shower & 900 SS Grab Rail
PRODUCT CODES:
-
TCS9J150C
-
TCS9C150C
-
TCS9J80C
-
TCS9C80C
SPECIFICATIONS
Grade 304 stainless steel grab rail with satin finish
Hygienic health safe flange covers
ABS slide cradle fastened and tensioned to the grab rail for handset support and movement
Strong and stylish ABS hand piece
PVC reinforced smooth and flexible spiral hose
Chrome on brass wall outlet elbow which features 9 L/min flow
Interchangeable spigot and separate licensed dual check/non return valves to prevent back
siphonage
80/150 mm CliniLever® contra rotating lever handles make showering easier for users with
disabilities or limited hand mobility
Handles are finished in bright chrome plate finish for added durability and easy cleaning
Suitable for installation and will assist in compliance to AS1428.1 – Design for access and mobility-
General requirements for access - New building work
IMPORTANT: All Galvin Engineering taps are tested in accordance with AS/NZS 3718 and leave our
premises in good working order.
TECHNICAL DATA
Inlet
Outlet
Headwork
Working Pressure Range (kPa)
Working Temperature Range (°C)
Finish
NOTE: Galvin Engineering continually strive to improve their products. Specifications may change
without notice.
TOOLS REQUIRED
Power drill
Spanner or adjustable crescent
© Galvin Engineering Pty Ltd
TCS9J150C / TCS9J80C
TCS9C150C / TCS9C80C
Version 1, 4 November 2022, Page 1 of 7
Version 1, 4 November 2022, Page 1 of 7
½" BSP – Female
Handheld Shower
Jumper Valve
Ceramic Disc
Min
150
Max
500
Min
5
Max
55
Chrome
Document No.: 001.00.10.16

Advertisement

loading

Summary of Contents for Galvin Engineering TCS9J150C

  • Page 1 Suitable for installation and will assist in compliance to AS1428.1 – Design for access and mobility- General requirements for access - New building work IMPORTANT: All Galvin Engineering taps are tested in accordance with AS/NZS 3718 and leave our premises in good working order.
  • Page 2: Installation

    Document No.: 001.00.10.16 Product Installation Guidelines Version 1, 4 November 2022, Page 2 of 7 PRE- INSTALLATION MOUNTING DETAILS - SHOWER © Galvin Engineering Pty Ltd...
  • Page 3 Version 1, 4 November 2022, Page 3 of 7 MOUNTING DETAILS – WALL TOP ASSEMBLY Wall body − Wall body must be G5/8” FI and body should be between 0 and 15mm behind the finished wall surface. 80/150 mm Wall Top Assembly © Galvin Engineering Pty Ltd...
  • Page 4 Version 1, 4 November 2022, Page 4 of 7 INSTALLATION - SHOWER INSTALLATION COMPLIANCE: Galvin Engineering products must be installed in accordance with these installation instructions and in accordance with AS/NZS 3500, the PCA and your local regulatory requirements. Water and/or electrical supply conditions must also comply to the applicable national and/or state standards.
  • Page 5 Fit elbow over spigot and secure with grub Connect hose and shower head ensuring the screw. connection is secured, then turn on water supply. Using 2.5mm hex key supplied, tighten 5mm Check for any leaks. grub screw. © Galvin Engineering Pty Ltd...
  • Page 6 They should turn freely for a full ¼ turn. − Secure the handle in position using the supplied washer and stainless steel cap screw. © Galvin Engineering Pty Ltd...
  • Page 7: Troubleshooting

    The warranty set forth herein is given expressly and is the only warranty given by the Galvin Engineering Pty Ltd. With respect to the product, Galvin Engineering Pty Ltd makes no other warranties, express or implied. Galvin Engineering Pty. Ltd. hereby specifically disclaims all other warranties, express or implied, including but not limited to the implied warranties of merchantability and fitness for a particular purpose.