Download Print this page
Watermark Reefe rainpro RM1500-2 Installation And Operating Instructions Manual

Watermark Reefe rainpro RM1500-2 Installation And Operating Instructions Manual

Rain to mains changeover valves

Advertisement

Quick Links

RM1500-2 and RM1600-2
RAIN TO MAINS
CHANGEOVER VALVES
Installation and Operating Instructions
1

Advertisement

loading

Summary of Contents for Watermark Reefe rainpro RM1500-2

  • Page 1 RM1500-2 and RM1600-2 RAIN TO MAINS CHANGEOVER VALVES Installation and Operating Instructions...
  • Page 2 • Suitable for any pressure pump with sufficient • Solid Brass mounting bracket (optional) head pressure • Watermark approved to WMTS477/LN60075 • Can be mounted in any position • Does not require regular maintenance • Built-in dual check valve for backflow prevention •...
  • Page 3 Flow Rates - RM1600-2 Flow Rate [L/min] Pressure drop verssus flow rate between the mains water inlet side and the outlet of the device Flow Rate [L/min] Pressure drop verssus flow rate between the rainwater inlet side and the outlet of the device...
  • Page 4 1" BSP F Loose Nut Fig. 2 Fig. 1 Rubber Washer To House Mains Water In RM1500-2 or RM1600-2 valve RM1500-2 or RM1600-2 valve PRESSCONTROL Power On Pump On Failure Restart Pressure Controller Pump WARNING!!! See also "IMPORTANT INSTALLATION & WARRANTY CONDITIONS"...
  • Page 5: Specifications

    Connection All plumbing connections should be carried out by a Fig 3. Shows a typical installation for a submersible licensed plumber. pump. Step 1. Fig 4. Shows the RM1500-2 or RM1600-2 mounted to The RM1500-2 or RM1600-2 Valve is fitted onto the wall/ other surface using the optional bracket the pump controller as shown in Fig 1.
  • Page 6: Parts List

    Parts List 150.3 RM1600-2 No. Component Qty Material RM1500-2 / RM1600-2 Body DZR Brass End Cap DZR Brass DN25 Nut Brass Brass Tail DZR Brass 1/8 BSP Plug Stainless Steel Dual Check Valve Additional Outlet Port (RM1500-2 only) 210.0 RM1500-2...
  • Page 7: Troubleshooting

    Trouble Shooting Symptom Cause Remedy Wait for tank to fill. No water is Rainwater tank is Check power supply & plug. delivered from empty. No Power. Restart pump. pump or pump Isolation Valve is shut. Open isolation Valve. performance is Pump is not primed.
  • Page 8: Warranty Information

    Warranty Information RM1500-2 and RM1600-2 warranty for Australia and New Zealand The RM1500-2 and RM1600-2 valve is guaranteed for a period of 2 years from the date of original purchase to be free of material or manufacturing defects. Should any part fail as a result of such defects within this...

This manual is also suitable for:

Reefe rainpro rm1600-2