WAC AiSPiRE A2D50-60 Installation Instruction

24vdc dim-to-warm power supply

Advertisement

Quick Links

INSTALLATION INSTRUCTION
24VDC Dim-To-Warm POWER SUPPLY
A2D50-60, A2D50-96
SAFETY INSTRUCTION
IMPORTANT: NEVER attempt any work without shutting off the electricity.
Always turn off power at fuse box prior to installation to prevent electrical shock.
For installation and serviced by a qualified, licensed electrician.
Install in accordance with national electric code, and local regulations.
Consult with local inspector to assure compliance.
CAUTION
Read all instructions before installing.
Handle product with care.
Do not modify or disassemble product beyond instructions or warranty will be void.
Failure to follow safety warnings, and installation instruction will void the warranty
This power supply is designed to work with only AiSPiRE Dim-To-Warm tape light.
FEATURES
Protection: short circuit/over loading/over temperature
24VDC Output, 4A Max (96W) & 2.5A Max (60W) Output Current on each output channel, ≥ 0.9 pf
Ambient Temp: -20ºC to 45ºC (-4°F to 113°F)
Full protection aluminum housing for dry and damp location
PRODUCT DIMENSION:
60W & 96W
waclighting.com
Headquarters/Eastern Distribution Center
Phone (800) 526.2588
44 Harbor Park Drive
Fax
(800) 526.2585
Port Washington, NY 11050
AiSPiRE retains the right to modify the design of our products at any time as part of the company's continuous improvement
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Ave
Ontario, CA 91761
program. March 2022
1.

Advertisement

loading

Summary of Contents for WAC AiSPiRE A2D50-60

  • Page 1 INSTALLATION INSTRUCTION 24VDC Dim-To-Warm POWER SUPPLY A2D50-60, A2D50-96 SAFETY INSTRUCTION IMPORTANT: NEVER attempt any work without shutting off the electricity. • Always turn off power at fuse box prior to installation to prevent electrical shock. For installation and serviced by a qualified, licensed electrician. •...
  • Page 2 INSTALLATION INSTRUCTION 24VDC Dim-To-Warm POWER SUPPLY A2D50-60, A2D50-96 WIRING AND INSTALLATION: 1. Turn Power off at circuit breaker 2. Mounting Enclosed 24VDC Dim-To-Warm class 2 output remote power supply at desired location. Measured a distance between power supply to the beginning of the tape run and make sure that it is under 100ft.The allowed maximum distance of wires between the output of power supply to the beginning of tape is 100 ft.
  • Page 3 INSTALLATION INSTRUCTION 24VDC Dim-To-Warm POWER SUPPLY A2D50-60, A2D50-96 Hard Wire: Enclosed 24VDC Dim-To-Warm class 2 output remote power supply must be installed away from any • heat sources and it must be accessible for service. • Enclosed 24VDC Dim-To-Warm class 2 output remote power supply is UL listed. •...
  • Page 4 INSTALLATION INSTRUCTION 24VDC Dim-To-Warm POWER SUPPLY A2D50-60, A2D50-96 SYSTEM DIAGRAM: ON/OFF Switch System ELV Dimmer Control System 0-10V Dimmer Control System CAUTION: AISPIRE Dim-To-Warm Tape light may not be able to dim with other power supply brands. Using only designated power supply to achieve best dimming result. waclighting.com Headquarters/Eastern Distribution Center Central Distribution Center...

This manual is also suitable for:

Aispire a2d50-96