Download Print this page

A LED Brida Operating Manual

Sensor cct

Advertisement

Quick Links

4. Contact an authorised technical service centre for any repairs possibly required use only original spare parts.
5. Do not touch LED while installing or maintaining.
6. Sealing the entrance hole with glue after install is needed.
7. The light source contained in this luminaire shall only be replaced by the manufacturer or his service agent or a
similar qualified person.
Instruction for Light Source Disassembly
1
Unscrew the diffuser anticlockwise and vertically
take it out.
3
On the reverse of diffuser, use the screwdriver to
pry the clips to release the PCBA, then twist the
PCBA anticlockwise.
* This product contains a light source of energy efficiency class <D>
IP65
IK10
A LED A/S Hammeren 6, DK-6800 Varde www.aled.dk +45 71995354
2
Disconnect the DC power cable from the driver.
4
Take out the PCBA (light source) from the diffuser.
RoHS
OPERATING MANUAL
Brida - Sensor CCT
Important: Please read the instruction manual carefully prior to installation and keep it for future reference.
Product
Power
Function
Ordering Code
(W)
Description
Fitting Series
Sensor DIM,
Brida Sensor CCT
color temperature
Brida
18
Hvid / Sort
selectable, power
switchable
Accessories
No.
Pic.
Qty.
Usage
1
3
Fix light
2
3
Rawl plug
Vandal proof
1
3
screw tool
4
3
Plastic washer
5
2
Fix cable clip
6
1
Cable clip
7
1
Cable clip
8
4
Plastic plug
Installation
1
Unscrew the diffuser anticlockwise.
Vertically remove the diffuser and PCBA.
55
290
Mounting: Wall or Ceiling
Light features:
Ra: >80
Life Time: 5 years
Light Source: LED SMD2835
Input: 220V-240V 50/60Hz
C0/180,110.1
C60/240,109.5
C30/210,110.5
C90/270,108.9
CCT:
1 2
Power
Electric Current
I
3000K
300mA
11W
II
3500K
350mA
13W
1 2
III
4000K
500mA
18W
Colour Temperature Code
Lumen
Code
Colour Temperature
CCT(K)
Hvid
Sort
30K
Warm White
3000
2070
1980
35K
Natural White
3500
2160
2030
40K
Cool White
4000
2196
2070
2
a. Cut off the power. Thread the input cable through the
rubber plug to the fixture. Connect the L, N wire
referring to the wiring diagram.
b. Knock the rawl plugs into the pre-drilled holes on ceiling
/wall. Wear plastic washers on self-tapping screws and
tighten them to fix the fixture on ceiling/wall.

Advertisement

loading

Summary of Contents for A LED Brida

  • Page 1 RoHS IP65 IK10 b. Knock the rawl plugs into the pre-drilled holes on ceiling /wall. Wear plastic washers on self-tapping screws and tighten them to fix the fixture on ceiling/wall. A LED A/S Hammeren 6, DK-6800 Varde www.aled.dk +45 71995354...
  • Page 2 Stand-by time I – 0s II – 10s This is the time period that the light remains at a low level III – 10min before it is completely turned off. 10min IV – +∞ Stand-by period +∞ 0s~+ Stand-by dim level I –...

This manual is also suitable for: