Jameson Aftercooler: Operation and Maintenance Manual
Description of operation
A Jameson Aftercooler is a portable system consisting of an air-cooled trim cooler and a
separator/filter. Wet warm air enters the trim cooler where it is cooled to a temperature
approaching ambient. Water is condensed out during this cooling process. The saturated air
and the liquid water proceed to the inlet of the separator/filter where the liquid water is
removed. The process air out of the system is ready for use.
SPECIFICATIONS
2.1 INLET CONDITIONS
Refer to Table 1 below for the recommended operating conditions for the available
Jameson Aftercooler models.
Maximum Working Pressure (PSI)
Maximum Working Temperature
Aftercooler (°F)
Maximum Working Temperature
Separator (°F)
Minimum Recommended
Temperature (°F)
Internal Airflow Rotary
Compressor (Max CFM)
Internal Airflow Piston
Compressor (Max CFM)
Max Air Pressure to Motor (PSI)
Motor Air Consumption (CFM)
Max Fan RPM
Table 1: Inlet Conditions
1451 Old North Main Street | Clover, SC 29710 | 800.346.1956
JAMESONLLC.com
JAC-245
JAC-540
250
250
250
250
150
150
35
35
245
539
181
432
60
40
17
25
3450
1725

Advertisement

loading

Summary of Contents for Jameson Aftercooler JAC-245

  • Page 1 Jameson Aftercooler: Operation and Maintenance Manual Description of operation A Jameson Aftercooler is a portable system consisting of an air-cooled trim cooler and a separator/filter. Wet warm air enters the trim cooler where it is cooled to a temperature approaching ambient. Water is condensed out during this cooling process. The saturated air and the liquid water proceed to the inlet of the separator/filter where the liquid water is removed.
  • Page 2 2.2 DIMENSIONS Figure 1: Dimensional drawing Dimension JAC-245 JAC-540 30.0” (762mm) 36.2” (920mm) 42.0” (1067mm) 42.0” (1067mm) 24.7” (628mm) 28.9” (627mm) 25.1” (638mm) 30.2” (767mm) Table 2: Overall Dimensions Inlet Options JAC-245 JAC-540 1451 Old North Main Street | Clover, SC 29710 | 800.346.1956 SpartacoGroup.com...
  • Page 3 Outlet Options JAC-245 JAC-540 Operation The simple design of the system allows for easy operation. The system requires daily filter draining and periodic cooler draining to ensure peak performance. Setup 1. Connect air line from compressor to inlet side of aftercooler, ensure proper safety clips are installed.
  • Page 4 Motor Filter Draining - The accumulated water and oil solution should be drained from the main filter every 2 to 4 hours (or as required based on environmental conditions). Locate the drain valve at the bottom left of the motor regulator assembly. Turn the fitting to open the valve and drain liquid from the filter assembly.
  • Page 5 Wheel DR200321 Wheel Nut DR200323 To order parts contact your local Jameson representative, the representative that sold the aftercooler, or the factory. When ordering parts, have the system model number ready. Jameson Customer Service can be reached by calling 800-346-1956.

This manual is also suitable for:

Aftercooler jac-540