Download Print this page
QL 140E-1 Series Operating Manual

QL 140E-1 Series Operating Manual

General purpose incubators

Advertisement

Quick Links

Quincy Lab, Inc.
Model 12-140E-1
SPECIFICATIONS
Interior Dimensions
Exterior Dimensions
Weight (lbs)
Cubic Foot Capacity
Standard Electrical: 230 volts, 50/60 Hz
Temperature Range
Common Unit Specifications
Operating Environment: Indoor use, altitude to 6,500 ft. (2,000m) Installation Category II,
Storage Temperature:
Approvals:
Compliance:
Common Unit Construction
Exterior: Powder-Coated Steel
Insulation: Fiberglass
Thermo-control: PID Microprocessor
Issue Rev C 0310
Copyright Quincy Lab Inc. 2009
Model Series 140E-1 & 180E-1 (230 V )
10-140E-1
12x10x10
INCHES W x H x D
31x25x25
(CM) W x H x D
13x15x11
INCHES W x H x D
33x38x28
(CM) W x H x D
19 lbs
WATTS
Pollution Degree 2, ambient temperature 10
80% RH maximum.
o
-10
C/14
Underwriter's Laboratory Listed, Laboratory Equipment, C/UL
United States/Canadian. E212550 (115VAC models only)
UL Standard 61010-1, IEC 61010-1, 2nd Edition.
Quincy Lab, Inc.
1925 N. Leamington Ave.
General Purpose Incubators
MODEL
MODEL
12-140E-1
18x16x12
46x41x30
19x21x13
48x53x33
33 lbs
120
235
o
o
o
F to 70
C/158
F, 70% RH maximum.
Interior: Aluminum
Door: 140E-1:Acrylic, 180E-1:Steel Insulated
Heater: Resistive-Tubular Incoloy
Chicago, Illinois 60639
OPERATING MANUAL
Model 10-180E-1
MODEL
MODEL
10-180E-1
12-180E-1
12x10x10
18x16x12
31x25x25
46x41x30
13x15x11
19x21x11
33x38x28
48x53x33
19 lbs
33 lbs
270
385
o
o
C/50
F to 35
1-800-482-HEAT (4328)
o
o
C/95
F,
PAGE 1

Advertisement

loading

Summary of Contents for QL 140E-1 Series

  • Page 1 Model Series 140E-1 & 180E-1 (230 V ) General Purpose Incubators Quincy Lab, Inc. OPERATING MANUAL Model 10-180E-1 Model 12-140E-1 MODEL MODEL MODEL MODEL SPECIFICATIONS 10-140E-1 12-140E-1 10-180E-1 12-180E-1 Interior Dimensions 12x10x10 18x16x12 12x10x10 18x16x12 INCHES W x H x D 31x25x25 46x41x30 31x25x25...
  • Page 2 Safety Precautions Read Operating Instructions Thoroughly Prior to Operation Read Operating Instructions thoroughly prior to operation. Use only a grounded outlet that is rated for your model's electrical requirement. Do not modify the oven or factory control settings to operate the oven above the stated maximum operating temperature.
  • Page 3 Control Menu Functions Access the menu levels for the following functions: (user applicable functions and FUNCTION SETTING their menu locations are high-lighted in white in the Functions Menu Guide below). Alternating ~ Change control to read in C or F temperature units.( in level 2) Display ~ Change to whole degree or 1/10th degree display resolution.(...
  • Page 4 TIP: To avoid erroneous tracking data from run-up temperatures or door openings, start the Tracking feature after articles have been placed and temperature steadies at set point. Control Self Diagnostics Control prompts will only display when a fault or alarm condition exists. Example for 140E-1 Series PRESS (Press together to...

This manual is also suitable for:

180e-1 series10-140e-112-140e-110-180e-112-180e-1