TABLE 1
(Specifications)
Model
Repair Kit
Type
Number
Number
20-100-597
Single
06-400-177
20-100-605
Single
06-400-177
20-100-606
Single
06-400-177
20-100-639
Single
06-400-177
20-100-640
Single
06-400-177
20-100-641
Single
06-400-177
20-100-758
Dual
06-400-250
NOTE: If your product number is not listed, please contact MICO, Inc. for information.
This document is intended to provide general information about MICO Products. MICO, Inc. has attempted to present accurate information about MICO Products in its catalogs,
brochures, and other printed materials. MICO, Inc. is not responsible for errors, inaccuracies, or inconsistencies that may exist in any catalog, brochure, or other printed materials or
any damages arising from or related to reliance on information in them. Materials and specifications for MICO Products set forth in catalogs, brochures, and other printed materials
are subject to change without notice or obligation. Refer to www.mico.com for the most recent versions of our literature. If you have any questions concerning MICO Products, please
contact MICO, Inc. All MICO Products and service are sold and provided subject to the MICO Warranty at www.mico.com in effect on the date of sale or supply.
MICO is a trademark and registered trademark of MICO, Inc. MICO is registered in the U.S. Patent and Trademark Office as well as in Australia, Canada, Indonesia, Japan, Peoples Republic of China, South Korea, and the European Community.
Form No. 81-463-016
Nominal
Accumulator
Charge Rate
69.0 bar @ (1000 PSI)
L/min
(GPM)
bar
7.57 ± 1.89
(2.00 ± 5)
134.5 ± 3.5
7.57 ± 1.89
(2.00 ± 5)
193.0 ± 3.5
4.28 ± 1.44
(1.13 ± .38)
186.2 ± 3.5
3.6 ± .95
(.95 ± .25)
134.5 ± 3.5
7.57 ± 1.89
(2.00 ± .5)
193.0 ± 3.5
4.28 ± 1.44
(1.13 ± .38)
186.2 ± 3.5
4.28 ± 1.44
(1.13 ± .38)
186.2 ± 3.5
Revised 2003-06-03
Priority/Charging
Accumulator
Accumulator
High Limit
Low Limit
(PSI)
bar
(1950 ± 50)
74.1 ± 3.5
(2800 ± 50)
132.7 ± 3.5
(2700 ± 50)
141.3 ± 3.5
(1950 ± 50)
74.1 ± 3.5
(2800 ± 50)
132.7 ± 3.5
(2700 ± 50)
141.3 ± 3.5
(2700 ± 50)
141.3 ± 3.5
MICO, Inc.
1911 Lee Boulevard / North Mankato, MN U.S.A. 56003-2507
Tel: +1 507 625 6426
Valve
Relief
Valve Setting
(PSI)
bar
(1075 ± 50)
168.9 ± 6.9 (2450 ± 100)
(1925 ± 50)
206.8 ± 3.5 (3000 ± 50)
(2050 ± 50)
203.4 ± 3.5 (2950 ± 50)
(1075 ± 50)
168.9 ± 6.9 (2450 ± 100)
(1925 ± 50)
206.8 ± 3.5 (3000 ± 50)
(2050 ± 50)
203.4 ± 3.5 (2950 ± 50)
(2050 ± 50)
203.4 ± 3.5 (2950 ± 50)
Fax: +1 507 625 3212
www.mico.com
(PSI)

Advertisement

loading

Summary of Contents for WABCO MICO 20-100-597

  • Page 1 Priority/Charging Valve Service Instructions TABLE 1 (Specifications) Nominal Accumulator Accumulator Relief Accumulator Model Repair Kit Charge Rate High Limit Low Limit Valve Setting Type Number Number 69.0 bar @ (1000 PSI) L/min (GPM) (PSI) (PSI) (PSI) 20-100-597 Single 06-400-177 7.57 ± 1.89 (2.00 ±...