Authorized Service Representatives are obligated to
follow industry standard safety procedures, including,
but not limited to, local/national regulations for
disconnection / lock out / tag out procedures for all
utilities including electric, gas, water and steam.
Disconnect electric power to the ice machine and
dispenser at the electric switch box before proceeding.
Failure to disconnect the power at the main power supply
disconnect could result in serious injury or death. The
power switch DOES NOT disconnect all incoming power .
Two or more people are required to move this equipment
to prevent tipping..
Two or more people are required to move this
equipment to prevent tipping..
This instruction pertains to two dispenser models. Follow
the instructions for the model you are working on either
FS9000 or FS9100.
FS9000 Assembly and Mounting
1. Move the ice machine and dispenser away from the
wall for easier access.
2. Bracket selection
A. Dual evaporator ice machines - Use bracket with
the shorter top flange.
B.
Single evaporator ice machines - Use bracket with
the longer top flange.
3. Remove all panels and control box cover from the ice
machine.
Warning
Warning
DANGER
Warning
2110 SOUTH 26TH STREET, MANITOWOC, WI 54220
Subject: K00459 - S Model Bin Thermostat Kit
ICE MACHINE ON COKE FS9000 OR FS9100
DISPENSER W/ADAPTER KIT
4. If an ice machine is already installed on the dispenser:
Remove the fasteners securing the ice machine to the
adapter (located on the rear of the dispenser).
Raise and support the installation side of the ice
machine.
5. Hook the bracket assembly onto the respective back
spacer flange. Locate bracket assembly as illustrated.
NOTE: Dimension is from the edge of the adapter to the
edge of the bracket.
Use long flange bracket
Single evaporator – 23.00" from right side of adapter.
Dual evaporator – 18.00" from right side of adapter
6. Lower/place ice machine on dispenser and secure ice
Use short flange bracket
machine to adapter with fasteners. It is important to
confirm that the ice maker is slid rearward contacting
the bracket and back spacer flange before re-fastening
(close gap).
Document Number: 000013527 Rev02 04/19
MANITOWOC ICE
800-545-5720
WWW.MANITOWOCICE.COM
Confirm presence of back
spacer flange fastened to
adapter and ice maker
23"
Confirm presence of back spacer
flange & vertical bracket fastened
to adapter and ice maker
18"
1 of 5

Advertisement

loading

Summary of Contents for Manitowoc FS9000

  • Page 1 2110 SOUTH 26TH STREET, MANITOWOC, WI 54220 800-545-5720 WWW.MANITOWOCICE.COM Instruction Sheet Subject: K00459 - S Model Bin Thermostat Kit ICE MACHINE ON COKE FS9000 OR FS9100 DISPENSER W/ADAPTER KIT 4. If an ice machine is already installed on the dispenser: Warning •...
  • Page 2 Subject: K00459 S Model Bin Thermostat FS9100 Assembly and Mounting FS9000 & FS9100 Continued 1. Move the ice machine and dispenser away from the 7. Route thermistor wire out towards the back of the wall for easier access. dispenser . Remove unused 7/8” diameter knockout on the back panel, snap fit the bushing over the exposed 2.
  • Page 3: Controller Wiring

    Toggle Switch together with wire nut.. Connections 11. Connect bin switch wires: Manitowoc Models A. Disconnect the red male/female connector bin switch wire and connect the red male wire from the controller to the red female bin switch wire. Connect the white male bin switch wire to the CONTROL SETTINGS white female wire of the controller.
  • Page 4: Check Procedure

    Subject: K00459 S Model Bin Thermostat SETTING CONTROL SET POINT VALUE CHECK PROCEDURE To program the thermostat, plug the120V power cord into If the control system does not function properly, verify that an outlet and follow the steps below to program the Ice the control is wired and set up properly.
  • Page 5 Subject: K00459 S Model Bin Thermostat 3. Check for proper operation. Important Perform Steps 1 and 2 before performing these steps: A. Disconnect the load from the output relay terminals. Reconnect the sensor leads and supply power to the control. C.