Precautions
• Before using the Linear Scale for the fi rst time, wipe with a clean cloth ideally soaked with cleaning oil.
• This M-SURE Linear Scale is a precision measuring instrument. Avoid using excessive force, and treat with care.
• The fi tted battery is intended for the factory test procedure and therefore may not meet the specifi ed battery life.
• Avoid exposure to all liquids, excessive humidity or temperature.
• Avoid exposure to bright sunlight.
• Never apply voltage on any part of this Linear Scale or electric engrave.
• Remove the battery if the Scale is not being used for a long period of time.
• Never use solvents to clean. Only use a soft cloth with cleaning oil.
• Ensure the Linear Encoder is mounted parallel and in correct alignment to the machine axis.
Linear Digital Scale
3
1
2
0
45
40
35
30
25
Battery Replacement
1
1. Insert the key into the battery cover.
2. Twist to unlock. DO NOT use
excessive force.
6
6. Insert the replacement battery with
its edge against the side battery contact.
7. Press down on the opposite edge.
www.m-sure.co.uk - Allendale Group Ltd, Pindar Road, Hoddesdon, Hertfordshire. EN11 0BZ.
Images & Content ©2020 Allendale Group Limited. E&OE - Specifi cations subject to change without prior notice.
4
7
6
5
8
Horizontal Type
5
The Linear Scale must be aligned
10
parallel to the machine travel. Use a
15
20
Dial Gauge or DTI to set parallel.
The travel of the reading head must
also be aligned correctly to the Scale
beam, otherwise damage will occur.
(MS-270 Series only)
2
3. Lift out the battery cover.
7
8. Locate the two lugs on the battery
cover with the two slots on the Scale.
Insert the battery cover.
3
4
6
3
4. Remove the battery.
be used)
5. Locate the side spring battery contact.
8
9. Twist to lock. DO NOT use
excessive force.
Part No: MS-270 & 272 Series
Doc V: 1.0
1
Vertical Type
2
8
7
5
1. Beam clamp
2. Beam
3. Reading head
4. LCD display
5. Function button
6. Battery cover
7. Data output cover
8. Reading head fi xing - M3
4
5
(A magnet tip tool can
9

Advertisement

loading

Summary of Contents for M-Sure MS-270 Series

  • Page 1 • Before using the Linear Scale for the fi rst time, wipe with a clean cloth ideally soaked with cleaning oil. • This M-SURE Linear Scale is a precision measuring instrument. Avoid using excessive force, and treat with care. • The fi tted battery is intended for the factory test procedure and therefore may not meet the specifi ed battery life.
  • Page 2 Adjust parallel with dial gauge/DTI Low ambient temperature Store at normal room temperature www.m-sure.co.uk - Allendale Group Ltd, Pindar Road, Hoddesdon, Hertfordshire. EN11 0BZ. Images & Content ©2020 Allendale Group Limited. E&OE - Specifi cations subject to change without prior notice.