FOR MODELS
X1000SOD, X1200SOD
General
This transformer is to be installed in accordance with Article 450 of
the National Electric Code. The transformer must be installed in a well-
ventilated area free from explosive gases and vapors. Proper operation
requires for free flow of air. This driver should only be installed by a
qualified electrician.
Precautions Before Installing
Check the label and ensure the driver has the proper input voltage and
wattage for the job. Check the wire markings to ensure they match the
wiring diagram on this installation guide.
Mounting
Select a suitable location capable of supporting the weight of the
transformer. Use the key holes in the wire housing and third hold on
the ange when mounting. It is recommended that the transformer
be mounted vertically with the wiring compartment pointing down.
Recommended spacing between drivers is 5".
Keyhole
5" Min.
Spacing
Wiring
Compartment
Input Connections / Grounding
1
Remove wire compartment cover plate.
Magnitude, Inc.
14711 Bentley Circle. Tustin, CA 92780
120VAC / 12/24VAC / 1000-1200W
Quick Specs
Input Voltage
Output Voltage
Max. Ambient Temp.
Enclosure
Min. Installation Space
Between Drivers
Remove knockouts and install wire strain reliefs.
www.MagnitudeInc.com
INSTALLATION GUIDE
X-SERIES
120V AC
12/24VAC
-300 C to 500 C (-22°F - 122°F)
Dry & Damp
5" Inch