The DCM is a 2-way supervised transmitter that combines the Magnetic/Door Contact (against opening doors and windows) with an additional universal input or shutter. The DCM operates with PIMA’s 2-way wireless systems – FORCE and VISION series. MAIN FEATURES • Communication: 2-way •...
• Selective input response: 10 / 500ms • Tamper protection: Back + cover LED INDICATION • Upon successful learning: short flash sequence • Normal operation: brief light upon transmission • Low battery: short flash sequence during transmission OPERATING MODE The DCM reports events from IN2 and from the magnetic reed switch. In normal operation mode, an alarm is sent when the input or magnet are triggered.
Page 5
NOTE: After enrollment or after exiting the control panel’s Programming mode, the magnet will receive 2-Way data from the control panel for approx. 30 seconds. During this time, the magnet will not respond to any trigger but only to tamper activation. At the termination of this time, the magnet will revert to normal operation.
Page 6
Battery Life: 3 years typical Standards EN50131-2-6 Grade 2, Environmental Class II, EN50131-6: Type C PD6662:2017 Specifications are subject to change without prior notice. Should any questions arise please contact your supplier. ORDERING INFORMATION Model Frequency DCM743 433MHz 8841202 DCM786 868MHz 8841203...
UKCA and CE RED compliance statement Hereby, PIMA declares that this equipment is in compliance with the essential requirements of the UKCA Radio Equipment Regulations 2017 and CE Directive 2014/53/EU. For the UKCA and CE Declaration of Conformity please refer to our website: www.pima-alarms.com...