Download Print this page

Intermatic SG160 User Manual

Sg modular series hardwired surge protection devices

Advertisement

Quick Links

HARDWIRED SURGE PROTECTION DEVICES
SG Modular Series
TRANSIENT SURGE SUPPRESSORS FOR
AC POWER PANEL APPLICATIONS
R
R
LISTED
LISTED
1449 2nd Edition

Advertisement

loading

Summary of Contents for Intermatic SG160

  • Page 1 HARDWIRED SURGE PROTECTION DEVICES SG Modular Series TRANSIENT SURGE SUPPRESSORS FOR AC POWER PANEL APPLICATIONS LISTED LISTED 1449 2nd Edition...
  • Page 2 HECK TO ENSURE THAT ALL CONNECTIONS ARE CORRECT AND SECURE BEFORE ENERGIZING NOT ENERGIZE WITH DOOR OPEN EEP THIS MANUAL IN A SAFE DRY PLACE FOR FUTURE REFERENCE APPLICATION or TECHNICAL ASSISTANCE Contact Intermatic at 1-800-391-4555 or on the web at www.intermatic.com 12.94" (329mm) 14.75"...
  • Page 3 Before starting the installation, measure the Line voltage with an AC voltmeter to ensure the correct device has been selected for the current application. The MCOV (maximum continuous operating voltage) Cannot exceed the maximum limits for the following service voltages: 120VAC=150MCOV 220VAC=320MCOV 230VAC=320MCOV...
  • Page 4 CAUTION: BEFORE ENERGIZING THE SPD: ENSURE ALL CONNECTIONS ARE CORRECT. DO NOT ENERGIZE WITH FRONT COVER OPEN. [Figure #9: 3 Phase Wye Wire Hook-up] 1. CONNECT THE GROUND WIRE TO THE SERVICE PANEL GROUND BUS. 2. CONNECT THE NEUTRAL WIRE FROM THE SERVICE PANEL NEUTRAL BUS TO THE LUG LABELED NEUTRAL.
  • Page 5: Status Indicators

    STATUS INDICATORS GREEN LEDs: When the SPD is securely connected and operating properly, the GREEN LEDs, under the heading "PHASE INDICATORS", will be illuminated. No other indicator should be illuminated if the unit is operating normally. RED LED: If a problem develops with the internal monitoring circuitry or, in the unlikely event that there should be a loss or reduction in the protection elements, the RED LED over the words "SYSTEM FAULT"...
  • Page 6 DRY CONTACT INTERFACE LOCATION OF OPTIONAL SURGE COUNTER AC Service: 277/480Vac, Three Phase, 4 Wire + Ground THERE ARE NO USER SERVICEABLE PARTS INSIDE MAIN HOUSING SG160K, SG240K and SG320K Models: The specific product you have in service may be configured for any one of the following voltages: 120 or 240Vac, Single Phase 120/240Vac, Split Phase 240 or 480Vac, Three Phase Delta...
  • Page 7 At intervals not to exceed two (2) months check and verify: 1. Diagnostic and Indication display. 2. Alarm Operation 3. Condition of ALL Connection Cables and Terminations INSTALLATION, SERVICE OR REMOVAL OF THIS DEVICE SHOULD ONLY BE PERFORMED BY A QUALIFIED LICENSED ELECTRICIAN. ANY ALTERATIONS, TAMPERING, MISUSE OR UNAUTHORIZED REPAIRS OF THIS PRODUCT WILL VOID ITS ORIGINAL FACTORY WARRANTY.
  • Page 8 WARRANTY AND LIMITATION OF LIABILITY If within five (5) years from the date of purchase, this surge protection device fails due to defect in material or workmanship, Intermatic Incorporated will repair or replace it free of charge. The warranty does not apply to: (a) damage caused by accident, abuse, mishandling, dropping;...

This manual is also suitable for:

Sg160kSg240kSg320k