Tubular motor with built-in radio receiver and return channel, obstacle detection function and
YYGL35REIC-10/17
YYGL45REIC-20/15
REIC tubular motor is an InelControl system device for
automatic operation of external roller blinds, internal roller
blinds, ZIP screen blinds and shutter blinds.
The tubular motor features an obstacle detection function
and automatic limit switches.
The device includes a radio receiver with return channel. The
roller blind status signal sent via a return channel provides
full control over the device operation.
The roller blind curtain length must correspond to the length
of the guides to ensure correct operation of the tubular
motor.
1
Safety guidelines
General guidelines
The tubular motor with obstacle detection function is configured
by
default
to
and operation, provided that all guidelines and relevant safety
and
accident
prevention
Installation and repairs must be carried out by a trained and
qualified professional. Do not modify or change the tubular motor
in any way. All warranty repairs must be carried out by the
manufacturer. Use genuine spare parts and accessories only.
The operational safety of the tubular motor can only be
guaranteed if the device is used as intended. The limit values
provided
in
the
exceeded under any circumstances.
Additional safety regulations
Follow the relevant safety and accident prevention regulations
when installing, commissioning and maintaining the tubular
motor. In particular, observe the following:
1. Fire safety regulations.
2. Accident prevention regulations.
General information on hazards and safety
measures
The following are the general guidelines for use of INEL devices
with other external devices. Follow the guidelines when installing
and operating these devices.
Caution - Failure to take precautions may result in
damage to the tubular motor, roller blind, roller blind
box, facade etc.:
• Check if all screw connections are secure before installing the
tubular motor with radio receiver and setting the limit positions.
Danger - Failure to take precautions may
result in injury or death.
• Check if the local voltage supply parameters
P. I. E. INEL Sp. z o. o., ul. Mostowa 1, 80-778 Gdańsk, inel@inel.gda.pl
electronic limit switches.
Installation and operation manual
guarantee
safe
installation
regulations
are
specifications
must
correspond to the device specification.
• Follow the relevant safety and accident prevention regulations.
• Use a circuit breaker for safe power supply disconnection (e.g.
fuse cut-off switch) for all connections.
• Check the power wires and cables regularly for damaged
insulation and continuity.
• Switch off the power supply before replacing damaged cables.
Warning
Do not let children play with the control devices.
• Keep the control devices out of reach of children.
• Observe the roller blind in motion at all times and keep other
people away until it is fully opened or closed;
• Provide training and instructions for the users on device
operation and related risks. The operator is deemed to have been
trained if the employer, administrator or owner of the device have
instructed and authorised the operator to operate the device.
2
Installation manual
2.1
Safety
• The device must be installed by qualified personnel only.
• The weight of the roller blind may not exceed the maximum
followed.
load of the drive specified in the selection table (see the end
of the instructions)
• Correct cable installation (loop facing down) will protect the
tubular motor against water damage.
• Do not drill holes in motor housing.
• Protect the motor against contact with liquids.
• Avoid shocks, impacts and damage to the motor.
not
be
Fig. 1
www.inel.gda.pl

Advertisement

loading

Summary of Contents for InelControl YYGL35REIC-10

  • Page 1 • Check the power wires and cables regularly for damaged insulation and continuity. REIC tubular motor is an InelControl system device for • Switch off the power supply before replacing damaged cables. automatic operation of external roller blinds, internal roller blinds, ZIP screen blinds and shutter blinds.
  • Page 2 The tubular motor will be automatically detected by the system after power on. For information about registering and configuring the tubular motor in InelControl system, see “Control unit user manual and InelControl system configuration”. Before starting/programming the tubular motor, check the roller blind curtain, guide and roller blind box condition and make sure the window is fitted with a window sill.
  • Page 3 Troubleshooting Motor selection table Problem: Motor is not responding Cause: Thermal protection tripped Roller blind height Solution: Wait for 10 to 20 minutes 1.5 m 2.0 m 2.5 m Roller tube Permissible roller blind weight by Problem: Roller blind curtain will not close Torque diameter height...