Download Print this page
SHENZHEN GUIYUAN INDUSTRY DEVELOPMENT S1DA-DC06 Manual

SHENZHEN GUIYUAN INDUSTRY DEVELOPMENT S1DA-DC06 Manual

Rf wireless receiver

Advertisement

Quick Links

RF Wireless Receiver (Model 0020348 S1DA-DC12)
Feature:
Application: It can be used in industry automation, agriculture automation and home automation, such as factory, house, farm, pasture, vehi c le, ship,
offshore operation, aerial vehi c le, field call, etc. It can remote control equipments on land, w ater and air, such as remote control lights, si r ens, locks,
motors, fans, w inches, blinds, linear actuators, doors, w i n dows, electric solenoid valves, security alarm, business signs and various devi c es.
Wireless control, easy to install.
Waterproof: The receiver has waterproof case and waterproof connector, it can be installed outdoors.
Relay Output: This recei v er i s relay output, it can be used to operate both DC and AC equipments. The terminal is NO / NC (normally open / normally
closed), which serves as a sw i t ch. That means you should also connect a separate power suppl y to it.
With w
ired control
terminals: You can connect sensors, limit sw itches, manual sw itches or external devices to control the receiver.
Adjustable delay time: 0 seconds ~ 99 hours
Design w ith low -power and high-speed CMOS technology.
You can turn on/ off the receiver w ith transmitter (remote control) from any place within a reliable distance.
Wireless RF signal can pass through walls, floors, doors or windows.
With reverse power protection and over current protection.
Reliable control: The receiver only works with the transmitter w hi c h use same code.
One/several transmitters can control one/several receivers simultaneously.
You can use two or more units in the same place.
Receiver:
Model No.: S1DA-DC06 / S1DA-DC09 / S1DA-DC12 / S1DA-DC24
Pow er Supply (Operating Voltage): DC6V (S1DA-DC06), DC9V± 1V (S1DA-DC09), DC12V± 1V (S1DA-DC12), DC24V± 1V (S1DA-DC24)
Output: Relay output (Normally open and normally closed)
Working Voltage Range of Relay: AC110~240V or DC0~28V
Transmitting Frequency: 315MHz / 433MHz
Channel: 1 CH
Control Mode: Delay (Press -> ON; Then OFF after the delay time)
Adjustable delay time: 0 seconds ~ 99 hours
Maximum Working Current: 10A / each channel
Static Current: ≤6mA
PCB size: 140mm x 73mm x 18mm
Case size: 192mm x 100mm x 45mm
Work w ith Fixed code transmitters or Learning code transmitters.
Matching Transm itters:
The receiver can work with di f ferent transmitters, such as model C-1 / C-2 (100M), CWB-1 / CWB-2 (50M, w aterproof), CP-1 / CP-2 /CV-2(500M), or
CB-1 / CB-2 (1000M), CBW-1 / CBW-2 (1000M, w aterproof) etc.
Working Range:
With a transmitter (such as C-2) to form a complete set, the w orking distance can reach 100M in an open ground. The maximum w orking distance
100M is a theoretical data, it shall be operated in an open ground, no barriers, no any interference. But in the practice, it w ill be hindered by trees,
walls or other constructions, and w ill be interfered by other wireless signals. Therefore, the actual distance may or may not reach 100M. If you want to
have a further working range, you can install an external antenna to the recei v er, and you also can use a powerful transmitter, such as CB
transmitters.
Usage (with the transmitter C-2):
The receiver can be used to control both DC 0~28V and AC 110~240V equipments.
Notice: The recei v er i s relay output, not DC/AC power output. Initial state of relay output terminals: Terminals A and B are Normally Open; Terminals A
and C are Normally Closed.
If you want to control a DC 12V lamp, do as following:
1) Connect the positive pole of DC pow er suppl y to terminal "L / +", and connect the negative pole of DC pow er suppl y to terminal "N / -".
2) Connect terminal C to the positive pole of DC pow er supply, connect terminal B to the positive pole of DC lamp, and connect the negative pol e of
DC lamp to the negative pole of DC pow er supply.
If you want to control an AC 220V lamp, do as follow ing:
1) Connect the positive pole of DC pow er suppl y to terminal "L / +", and connect the negative pole of DC pow er suppl y to terminal "N / -".
2) Connect terminal C to the live w ire of AC power supply, connect terminal B to one side of AC lamp, and connect another side of AC lamp to the
neutral w i r e of AC power supply.
Press button 1: Turn on relay (connect B and C, disconnect A and B), the lamp is on.
After delay time: Turn off relay by itsel f (disconnect B and C, connect A and B), the lamp is off.
Press button 2: Turn off relay immediately, no need to w ait for delay time.
Press buttons of "+" and "-" on the timer, adjust delay time from 0 second to 99 hours. "H" i s Hour, "M" is Minute, and "S" is Second.
For example, if you set "S 0 1", it means the delay time is 1 second.
SHENZHEN GUIYUAN INDUSTRY DEVELOPMENT CO.,LTD
Http://www.carymart.com
E-Mail: sale@carymart.com

Advertisement

loading

Summary of Contents for SHENZHEN GUIYUAN INDUSTRY DEVELOPMENT S1DA-DC06

  • Page 1 Receiver: Model No.: S1DA-DC06 / S1DA-DC09 / S1DA-DC12 / S1DA-DC24 Pow er Supply (Operating Voltage): DC6V (S1DA-DC06), DC9V± 1V (S1DA-DC09), DC12V± 1V (S1DA-DC12), DC24V± 1V (S1DA-DC24) Output: Relay output (Normally open and normally closed) Working Voltage Range of Relay: AC110~240V or DC0~28V...
  • Page 2 Operation: Press and hold the button of receiver until signal LED flashes slow l y ; release the button, LED keeps slow flash. That means all stored codes have been deleted successfully. SHENZHEN GUIYUAN INDUSTRY DEVELOPMENT CO.,LTD Http://www.carymart.com E-Mail: sale@carymart.com...
  • Page 3 Signal 1- Signal 1+ Timer Status LED Power LED Antenna Signal LED Relay Button DC Lamp DC Power supply DC Power supply B, C = Normally Open; A, B = Normally Closed SHENZHEN GUIYUAN INDUSTRY DEVELOPMENT CO.,LTD Http://www.carymart.com E-Mail: sale@carymart.com...

This manual is also suitable for:

S1da-dc09S1da-dc12S1da-dc240020348