MASTER SETUP AND OPERATIONAL INSTRUCTIONS
4300
Dual-Handed
Swing bolt
LOCK OPERATING CONVENTIONS:
+
User ID plus 6 digit PIN
+
Time Delay: Delay 01-99; Open 01-19
+
Duress (+/- last digit of combination, if enabled)
+
Single Access Mode - one combination required to open.
+
Dual Access Mode - two combinations required to open
(if enabled.)
+
Wrong Try (4 wrong combinations = 5 minute lock out)
+
If a mistake is made, wait thirty (30) seconds and
repeat operation.
+
Double signal - two (2) LED flashes and two (2) beeps -
indicates entry is valid or accepted.
+
Triple signal - three (3) LED flashes and three (3) beeps -
indicates invalid or not accepted.
LOCK USERS FUNCTIONS
Master User - Lock setup, add Users, and Master Reset
Manager User - Open Lock, Enable/Disable Users,
Delete/Reinstate User, set Time Delay, and Audit
Access User - Open Lock
+
User 02 -30
+
User 31 (Time Delay Override, if enabled)
NOTE: User IDs are underlined in the instruction
for identification purposes.
All locks are shipped from the factory in pre-setup mode,
with no features installed.
Lock will open when 1 is pressed.
EXIT PRE-SETUP
NOTE: Perform all Administrative Functions with the door open.
1.
Press and hold the "0" key until unit double signals.
2.
Enter the default Master Combination, 00 5-5-5-5-5-5.
+ Unit will signal twice.
Lock is now in setup and test mode.
+
ONLY the Master can enroll manager and users!
+
ONLY the manager can select operational modes: Time
Delay Override, Dual Mode, or Silent Alarm. (Special
Function 8, see configuration chart.)
V1.0_0212 | Division of Davcor Group Pty Ltd
LOCKS
6040
Dead bolt
ENTRY DEVICE OPTIONS
3750-K
Round Entry
Round Entry
KEYPAD SETUP
MASTER FUNCTIONS
To enroll/activate the Manager (Master only)
1.
Enter Master combination (00 555555) and hold down last digit
of combination until unit double signals and the LED stays on.
2.
PRESS 1 (add user).
3.
Enter Manager ID 01; lock should beep twice and LED stays on
4.
Enter the Manager ID 01 and combination XXXXXX. (Example:
01 123456)
5.
Re-enter 01 XXXXXX
6.
The Lock will double signal if the operation was successful, and
triple signal if not accepted.
Key press sequence – 00 555555(hold last) 1, 01, 01 123456, 01
123456
Manager is now enrolled and activate; to test enter the Manager
ID and combination; the lock should open.
NOTE: the Manager can open the lock, but all other "Manager
Function" will not be available until the Lock is in Operational
Mode (see Exiting Setup Mode.)
To enroll/activate Users (Master only)
1.
Enter Master combination (00 55555) and hold down last digit
of combination until unit double signals and the LED stays on.
2.
PRESS 1 (add user).
3.
Enter User ID (02-31); lock should beep twice and LED stays on.
4.
Enter User ID and combination XXXXXX (example: 02 222222).
5.
Re-enter ID XXXXXX
6.
The Lock will double signal if the operation was successful, and
triple signal if not accepted.
Repeat the process for each User enrolled.
NOTE: User 31 must be activated to use Time Delay Override.
NOTE: Each combination must be changed independently at the
Lock. When selecting a combination, do not use a birthday or
other predictable information that could give correlation between
the user and the combination.
|
www.smartlock.com.au
|
Supra v1.10
8130
(Optional)
3125
www.smartlock.co.nz
66E