MASTER SETUP AND OPERATIONAL INSTRUCTIONS
4300
Dual-Handed
Swing bolt
LOCK OPERATING CONVENTIONS:
+
User ID plus 6 digit PIN
+
Time Delay: Delay 01-99; Open 01-19
+
Duress (+/- last digit of combination, if enabled)
+
Single Access Mode - one combination required to open.
+
Dual Access Mode - two combinations required to open
(if enabled.)
+
Wrong Try (4 wrong combinations = 5 minute lock out)
+
If a mistake is made, wait thirty (30) seconds and
repeat operation.
+
Double signal - two (2) LED flashes and two (2) beeps -
indicates entry is valid or accepted.
+
Triple signal - three (3) LED flashes and three (3) beeps -
indicates invalid or not accepted.
LOCK USERS FUNCTIONS
Master User - Lock setup, add Users, and Master Reset
Manager User - Open Lock, Enable/Disable Users,
Delete/Reinstate User, set Time Delay, and Audit
Access User - Open Lock
+
User 02 -30
+
User 31 (Time Delay Override, if enabled)
NOTE: User IDs are underlined in the instruction
for identification purposes.
All locks are shipped from the factory in pre-setup mode,
with no features installed.
Lock will open when 1 is pressed.
EXIT PRE-SETUP
NOTE: Perform all Administrative Functions with the door open.
1.
Press and hold the "0" key until unit double signals.
2.
Enter the default Master Combination, 00 5-5-5-5-5-5.
+ Unit will signal twice.
Lock is now in setup and test mode.
+
ONLY the Master can enroll manager and users!
+
ONLY the manager can select operational modes: Time
Delay Override, Dual Mode, or Silent Alarm. (Special
Function 8, see configuration chart.)
V1.0_0212 | Division of Davcor Group Pty Ltd
LOCKS
6040
Dead bolt
ENTRY DEVICE OPTIONS
3750-K
Round Entry
Round Entry
KEYPAD SETUP
MASTER FUNCTIONS
To enroll/activate the Manager (Master only)
1.
Enter Master combination (00 555555) and hold down last digit
of combination until unit double signals and the LED stays on.
2.
PRESS 1 (add user).
3.
Enter Manager ID 01; lock should beep twice and LED stays on
4.
Enter the Manager ID 01 and combination XXXXXX. (Example:
01 123456)
5.
Re-enter 01 XXXXXX
6.
The Lock will double signal if the operation was successful, and
triple signal if not accepted.
Key press sequence – 00 555555(hold last) 1, 01, 01 123456, 01
123456
Manager is now enrolled and activate; to test enter the Manager
ID and combination; the lock should open.
NOTE: the Manager can open the lock, but all other "Manager
Function" will not be available until the Lock is in Operational
Mode (see Exiting Setup Mode.)
To enroll/activate Users (Master only)
1.
Enter Master combination (00 55555) and hold down last digit
of combination until unit double signals and the LED stays on.
2.
PRESS 1 (add user).
3.
Enter User ID (02-31); lock should beep twice and LED stays on.
4.
Enter User ID and combination XXXXXX (example: 02 222222).
5.
Re-enter ID XXXXXX
6.
The Lock will double signal if the operation was successful, and
triple signal if not accepted.
Repeat the process for each User enrolled.
NOTE: User 31 must be activated to use Time Delay Override.
NOTE: Each combination must be changed independently at the
Lock. When selecting a combination, do not use a birthday or
other predictable information that could give correlation between
the user and the combination.
|
www.smartlock.com.au
|
Supra v1.10
8130
(Optional)
3125
www.smartlock.co.nz
66E

Advertisement

loading

Summary of Contents for Davcor Smartlock Digital 4300

  • Page 1 Delay Override, Dual Mode, or Silent Alarm. (Special Lock. When selecting a combination, do not use a birthday or Function 8, see configuration chart.) other predictable information that could give correlation between the user and the combination. V1.0_0212 | Division of Davcor Group Pty Ltd www.smartlock.com.au www.smartlock.co.nz...
  • Page 2 Lock is now in operational mode, and the only function the NOTE: If Time Delay is active it may only be deactivated or delay Master can now perform is resetting the lock. value decreased in Open Period. V1.0_0212 | Division of Davcor Group Pty Ltd www.smartlock.com.au www.smartlock.co.nz...
  • Page 3 - LED flashes red at ten (10) second intervals. At the end of the delay period, two more consecutive invalid combinations will start the five (5) minute delay period. During delay period keystrokes will respond with three signals. V1.0_0212 | Division of Davcor Group Pty Ltd www.smartlock.com.au www.smartlock.co.nz...