Download Print this page

Zodiac jandy Pro Series Installation Instructions Manual

Gas-fired pool & spa heater blower spare parts installation

Advertisement

Quick Links

JXi
Gas-Fired Pool & Spa Heater
Spare Parts Installation Instructions
Blower
These instructions are to be used with the
following Jandy Pro Series spare parts kits:
R0591100
Blower Assembly

Advertisement

loading

Summary of Contents for Zodiac jandy Pro Series

  • Page 1 Gas-Fired Pool & Spa Heater ™ Spare Parts Installation Instructions Blower These instructions are to be used with the following Jandy Pro Series spare parts kits: R0591100 Blower Assembly...
  • Page 2 Improper installation and/or operation can create carbon monoxide gas and flue gases which can cause serious injury, property damage, or death. For indoor installations, as an additional measure of safety, Zodiac Pool Systems, Inc. strongly recommends installation of suitable carbon monoxide detectors in the vicinity of this appliance and in any adjacent occupied spaces.
  • Page 3 Page 3 Disassembly: Verify you have all necessary parts (see Table 1 below). KIT PART NO. COMPONENT DESCRIPTION QUANTITY R0591100 Blower Gasket Lock Washer, 1/4ʺ Nut, Hex Head Table 1. Replacement Kit parts Turn off the electrical power to the heater. Turn off the main gas supply to the heater.
  • Page 4 Page 4 Disconnect the air pressure switch wiring (yellow/black) and the gas valve wiring (brown) by unclipping the terminals from the PC board. Using a standard pipe wrench, disconnect the gas train at the union. 10. Using a 7/16ʺ wrench, remove four (4) nuts with fl at washers and star washers to disconnect the blower. 11. Remove two (2) screws to disconnect the air pressure switch from the blower (Figure 2). Figure 2. Remove Air Pressure Switch...
  • Page 5 Page 5 Assembly: Connect the air pressure switch to the new blower assembly (or install new air pressure switch, if necessary). Seat the blower on the combustion chamber lid and replace four (4) nuts, flat washers, and star washers. Tighten to 50 in-lbs. Reconnect the gas pipe to the blower by tightening the union. Replace four (4) bolts to secure the rear brace bar. Replace the front panel.
  • Page 6 Page 6...
  • Page 7 Page 7...
  • Page 8 2115 South Service Road West, Unit 3 Oakville, ON L6L 5W2 1.888.647.4004 | www.ZodiacPoolSystems.ca ZODIAC ® is a registered trademark of Zodiac International, S.A.S.U., used under license.All other trademarks referenced herein are the property of their respective owners. ©2014 Zodiac Pool Systems, Inc. H0439800 REV B...