CARE AND CLEANING
• Handle measuring instruments with care.
• Clean with soft cloth only after any use. If necessary damp
cloth with some water.
• If instrument is wet clean and dry it carefully. Pack it up only
if it is perfectly dry.
• Transport in original container/case only.
SPECIFIC REASONS FOR ERRONEOUS MEASURING
RESULTS
• Measurements through glass or plastic windows.
• Dirty laser emitting windows.
• After instrument has been dropped or hit. Please check
accuracy.
• Large fluctuation of temperature: If instrument will be used
in cold areas after it has been stored in warm areas (or
vice versa) please wait some minutes before carrying out
measurements.
SAFETY INSTRUCTIONS
• Follow up instructions given in user manual.
• Do not stare into beam. Laser beam can lead to eye injury.
A direct look into the beam (even from a greater distance)
can cause damage to your eyes.
• Do not aim laser beam at persons or animals.
• The laser plane should be set up above eye level of
persons.
• Use instrument for measuring jobs only.
• Do not open instrument housing. Repairs should be carried
out by authorised workshops only. Please contact York
Survey Supply Centre.
• Do not remove warning labels or safety instructions.
• Keep instrument away from children.
• Do not use instrument in explosive environment.
• The user manual must always be kept with the instrument.
LASER CLASSIFICATION
The instrument is a laser class 2 laser product according to
DIN IEC 60825-1:2007-03.
It is allowed to use unit without further safety precautions.
Eye protection is normally secured by aversion responses
and the blink reflex.
The laser instrument is marked with class 2 warning labels.
Follow us!
York Survey Supply Centre
Prospect House, George Cayley Drive, Clifton Moor, York, England YO30 4XE
@York_Survey
E-Mail: sales@yorksurvey.co.uk
@York_Survey
Ref:.. \operat98\instructions 21\263080.qxp 04-01-21
ELECTROMAGNETIC ACCEPTABILITY (EMC)
• It cannot be completely excluded that this instrument will
disturb other instruments (e.g. navigation systems).
• Will be disturbed by other instruments (e.g. intensive
electromagnetic radiation, nearby industrial facilities or
radio transmitters).
CE-CONFORMITY
Instrument has CE-mark according to EN EN 61010-1:20111-
07.
WARRANTY
• This product is warranted by the manufacturer to the
original purchaser to be free from defects in material and
workmanship under normal use for a period of two (2)
years from the date of purchase.
• During the warranty period, and upon proof of purchase,
the product will be repaired or replaced (with the same or
similar model at manufacturer's option), without charge for
either parts or labour.
• In case of a defect please contact York Survey Supply
Centre. The warranty will not apply to this product if it has
been misused, abused or altered. Without limiting the
foregoing, leakage of the battery, bending or dropping the
unit are presumed to be defects resulting from misuse or
abuse.
EXCEPTIONS FROM RESPONSIBILITY
• The user of this product is expected to follow the
instructions given in the operator's manual. Although all
instruments left our warehouse in perfect condition and
adjustment the user is expected to carry out periodic
checks of the product's accuracy and general performance.
• The manufacturer, or its representatives, assumes no
responsibility of results of a faulty or intentional usage or
misuse including any direct, indirect, consequential
damage, and loss of profits.
• The manufacturer, or its representatives, assumes no
responsibility for consequential damage, and loss of profits
by any disaster (earthquake, storm, flood, etc.), fire,
accident, or an act of third party and/or a usage in other
than usual conditions.
• The manufacturer, or its representatives, assumes no
responsibility for any damage, and loss of profits due to a
change of data, loss of data and interruption of business,
etc., caused by using the product or an unusable product.
• The manufacturer, or its representatives, assumes no
responsibility for any damage, and loss of profits caused by
usage other than explained in the user manual.
• The manufacturer, or its representatives, assumes no
responsibility for damage caused by wrong movement or
action due to connecting with other products.
York Survey Supply Centre
Tel: +44 (0) 1904 692723
Fax: +44 (0) 1904 690385
www.yorksurvey.co.uk
Multi-Digit Pro +
Code: 263080
Operating
Instructions
©York Survey Supply Centre 2021

Advertisement

loading

Summary of Contents for York Multi-Digit Pro+

  • Page 1 • Follow up instructions given in user manual. • In case of a defect please contact York Survey Supply • Do not stare into beam. Laser beam can lead to eye injury. Centre. The warranty will not apply to this product if it has...
  • Page 2 180° to extend the unit to 1m (see picture): that the instrument works precisely. Check of slope measurement Set the instrument down on a flat and even surface and Ref:.. \operat98\instructions 21\263080.qxp 04-01-21 ©York Survey Supply Centre 2021...

This manual is also suitable for:

263080