Page 2
It has been subjected to dynamic tests using a non shock absorbing lanyard and a 100kg mass in a 4m fall. The P+P line has also been tested with a static load of 36kN without failure.
P+P Anchorage Sling IMPORTANT: It is vital that anchor points are sufficiently strong, they should be capable of withstanding a minimum of 15kN horizontally and in the direction of the line. The high anchor rating is due to the vector forces generated in the high angle ‘Y’...
Page 4
(Fig. D). NOTE: On pre-2004 models there is no indication of how much tension is in the system. P+P recommend that only one hand Indicator is necessary without over exerting. Using both hands and over exerting, or using a lever is not necessary and at a height can be dangerous.
Page 5
These factors combine to reduce the graph on the next page, which explains the safe Fig. I clearance X when used with P+P Chunkie or NRG Fall Arrest Lanyards (Fig. H, I, J and K).
Page 6
Fig. J EXAMPLE A 15m line is set up at 1.25m above foot level, and a 2m P+P Chunkie or NRG Fall Arrest Lanyard is used to connect the user. The necessary clearance required is 5.2m below the user’s feet.
Page 7
(Fig. L). When this becomes clearly visible, it should be inspected and refurbished by P+P, for further details of the level of service in your area contact your supplier.