Industrial-grade plastic handle hand cups

Advertisement

Quick Links

THE ORIGINAL
& TRUSTED NAME
IN VACUUM LIFTING
EQUIPMENT
800.548.7341
WPG.com
908 West Main - P.O. Box 368
Laurel, Montana 59044 U.S.A.
406.628.8231 (phone)
406.628.8354 (fax)
Wood's Powr-Grip products are sold
through authorized dealers.
1LTS
Rev. 1.5 / 10-21 Plastic Troubleshooter
WOOD'S POWR-GRIP
Inspect the Hand Cup Regularly:
• Make sure the air filter is in place; if not, discontinue use until the filter is replaced.
• Examine the plunger and handle for cracks or other damage.
• Make sure the face of the vacuum pad feels grippy (not slick). Otherwise, replace the pad.
• Examine the vacuum pad for cuts or roughness on the sealing edges (see Inspect the Sealing Edges below).
• Periodically test the cup for excessive leakage (see Leak-Test the Hand Cup below), sluggishness
in plunger action or radical changes in the number of strokes needed to keep the red line hidden.
• If the cup does not function normally, review the TROUBLESHOOTING GUIDE (overleaf) to
determine which corrective action is needed.
Clean the Vacuum Pad:
• Remove the air filter from the pad face.
• Use a clean sponge or lint-free cloth to apply soapy water or another mild cleanser to the pad face.
• Never use solvents or rubber conditioners as a cleaning agent (see WARNINGS).
• To prevent liquid from contaminating the pump during cleaning, hold the cup facedown
or cover the suction inlet in the filter recess.
• If the pad has a felt strip at the edge, be careful not to dampen it.
• Wipe all residue from the pad face and allow the cup to dry.
• Reinstall the air filter.
Inspecting and Testing the Cup for Leakage
Inspect the Sealing Edges:
• Slowly draw your finger along the entire length of the sealing edges, to check for roughness or
foreign material.
• Examine the sealing edges for cuts by bending the edge of the pad face towards you to create a
hump, turning the hand cup as necessary.
• If cuts or cracks are present in a sealing edge, a V-shaped gap will appear.
• Any pad that exhibits a gap or excessive roughness in a sealing edge must be replaced.
Leak-Test the Hand Cup:
• Attach the cup to a clean, smooth, scratch-free piece of glass or metal for approximately 2 hours.
• The red line on the plunger serves as a vacuum indicator:
▪ If the red line does not appear during the test period, the cup is usable.
▪ If the red line does appear, perform general maintenance and repeat the test.
• If the problem persists, check the TROUBLESHOOTING GUIDE (overleaf) to identify possible
causes and appropriate corrective actions.
• If these measures do not restore the cup to normal performance, contact the Wood's Powr-Grip
Customer Service department or an authorized dealer for assistance.
Based on product information at time of publication. Environmental conditions can affect product performance and longevity;
consult the product instructions on www.WPG.com or contact a Technical Sales Representative for more information.
GUIDE TO MAINTENANCE,
®
TROUBLESHOOTING, AND REPAIR
General Maintenance
N4000, N4100, N5000,
N6000, N4000TS,
N5000CS, N6000P
Industrial-Grade
Plastic Handle
Hand Cups
32621

Advertisement

loading

Summary of Contents for WOOD'S POWR-GRIP N6000P

  • Page 1 • If these measures do not restore the cup to normal performance, contact the Wood’s Powr-Grip Customer Service department or an authorized dealer for assistance. Wood's Powr-Grip products are sold Based on product information at time of publication. Environmental conditions can affect product performance and longevity;...
  • Page 2 PARTS AND ASSEMBLY *Repair Kit #90160 90151AM Handle / Release Valve Assembly 90154AM Plunger Assembly 90158AM Plunger Assembly, High Elevation (for N4100) 49480T Vacuum Pad, 8" [20 cm] Dia., Flat, Lipped (VPFS8L) 49478T Vacuum Pad, 8" [20 cm] Dia., Flat, Lipped, Low-Marking (VPFS8L) 49495T Vacuum Pad, 8"...
  • Page 3 • Apply plunger lube all the way around the exposed surface of the U-cup. Be careful to keep lubricant off the button! • Plunger lube is recommended; contact Wood's Powr-Grip Customer Service to order this. • Do not use improper lubricants in the handle. •...
  • Page 4 This could prevent the red line from warning the user of vacuum loss. • Do not touch the release-valve lever while lifting. • Do not attach 10" [25 cm] diameter cups (models N6000 and N6000P) to thin, fragile materials.