Do you have a question about the Grand Teton PS60WTS and is the answer not in the manual?
Questions and answers
John Neff
April 8, 2025
I have a Grand Teton TS 130 by Mr heater it's a Wi-Fi connection with a Wi-Fi computer screen on it the power button keeps going off and I have to go manually push the power button back on to get it to start back up what could be wrong with it it does it throughout the day and overnight
1 comments:
Mr. Anderson
April 9, 2025
The power button on the Mr. Heater Grand Teton PS60WTS may turn off due to a high temperature sensor failure (sensor located below the pellet hopper), power failure, or issues such as a short or open circuit at temperature sensors. These conditions can trigger error codes like E7, ESC1–ESC3, or ESO1–ESO3, causing the stove to shut down.
This answer is automatically generated
John Neff
April 8, 2025
My pellet stove keeps shutting off throughout the day or in the middle of the night and I have to manually turn it back on on the screen from the Wi-Fi what could be the problem
1 comments:
Mr. Anderson
April 9, 2025
The Mr. Heater Grand Teton PS60WTS pellet stove may shut off unexpectedly due to the ECO 1 mode being enabled. In ECO 1 mode, the stove shuts off when the desired temperature is reached and restarts when the room cools to a preset level. Additionally, improper cleaning and maintenance—such as a blocked fire pot, ash drawer, or air passageways—can also cause shutdowns. The stove must also be turned off twice every 24 hours for cleaning if used continuously.
This answer is automatically generated
Related Manuals for Mr. Heater Grand Teton PS60WTS
Summary of Contents for Mr. Heater Grand Teton PS60WTS
Page 1
DEPARTMENT, FIRE PREVENTION BUREAU, ETC.) SHOULD BE CONSULTED BEFORE INSTALLATION TO DETERMINE ANY NEED TO OBTAIN A PERMIT. OBSERVE ALL LOCAL BUILDING CODES. Mr. Heater a subsidiary of Enerco Group Inc. 4560 West 160th st Cleveland, Ohio 44135 1-866-740-2497 66699 REV C...
GENERAL HAZARD WARNING: WARNING: FAILURE TO COMPLY WITH THE PRECAUTIONS FIRE, BURN, INHALATION, AND EXPLOSION AND INSTRUCTIONS PROVIDED WITH THIS HAZARD. KEEP SOLID COMBUSTIBLES, SUCH AS STOVE CAN RESULT IN DEATH, SERIOUS BUILDING MATERIALS, PAPER OR CARDBOARD, BODILY INJURY AND PROPERTY LOSS OR A SAFE DISTANCE AWAY FROM THE STOVE DAMAGE FROM HAZARDS OF FIRE, EXPLOSION, AS RECOMMENDED BY THE INSTRUCTIONS...
SPECIFICATIONS Model # PS60WTS PS130TS PSBF66WTS DIMENSIONS Stove Weight 198 (90) 221 (100) 265 (120) [LBS (kg)] Stove Dimensions LxWxH [in (cm)] 23.5” x 21.75 “ x 33.25” 24.0” x 24.5 “ x 36.5” 26.18” x 24.53 “ x 30.39” (59.7 x 55.2 x 84.5) (61.0 x 62.2 x 92.7) (66.5 x 62.3 x 77.2)
GETTING STARTED Allen Wrenches Display Panel Firepot Cover Main Power Cord (x2) ACCESSORY KIT Flex Hose Termination Cap Hose Clamp Fresh Air Adapter Cleaning Tool and Screws (x4) WHAT YOU’LL NEED (NOT SUPPLIED) TOOLS REQUIRED SAFETY EQUIPMENT (RECOMMENDED) • Tape Measure •...
CARBON MONOXIDE SAFETY PRECAUTIONS WARNING: HAVE AN ESTABLISHED PLAN FOR WHAT WHEN USED WITHOUT ADEQUATE TO DO IN THE EVENT OF A FIRE. CONTACT COMBUSTION AND VENTILATION AIR, THIS YOUR LOCAL FIRE AUTHORITY TO ACQUIRE STOVE MAY GIVE OFF EXCESSIVE CARBON INFORMATION AND A PLAN FOR WHAT TO DO MONOXIDE, AN ODORLESS, POISONOUS IN THE EVENT OF A CHIMNEY FIRE.
CLEARANCE TO COMBUSTIBLES • It has at least 2” (51 mm) of clearance from the rear to the nearest body. The following stated clearances represent the • Vertical runs of vent pipe must be at least 3” (76 minimum distances between the stove and any other mm) from any wall.
Page 7
UNPACKING 1. Remove heater from carton. 2. Remove all protective packaging applied to heater for shipment. 3. Check heater for any shipping damage. If any damage is found immediately contact the manufacturer at 866-740-2497. CAUTION: DAMAGED PARTS MAY Figure 2 PS60WTS and Figure 3 PSBF66WTS...
YOUR WARRANTY MAY BECOME VOID. READ powered devices which exhaust house air. AND FOLLOW ALL INSTRUCTIONS. Contact • There is excessive condensation on windows in the Mr. Heater with any comments, concerns, or winter. questions. • A ventilation system is installed in the house.
Page 9
• A International Conference of Building Officials CONNECTOR REQUIREMENTS AND ASSEMBLY (ICBO) standards for solid fuel Stoves code- CAUTION: A CHIMNEY CONNECTOR SHALL approved masonry chimney. NOT PASS THROUGH AN ATTIC OR ROOF VENT TERMINATION SPACE, CLOSET OR SIMILAR CONCEALED •...
Page 10
NFPA 211 (US ONLY) APPROVED WALL PASS THROUGH TECHNIQUES Figure 7 (US ONLY) Figure 9 (US ONLY) Brick Masonry: Minimum 3.5 inch (89 mm)thick brick Ventilated Thimble: Sheet steel chimney connector, masonry all framed into combustible wall with a minimum 24 gauge in thickness, with a ventilated minimum of 12 inch (305 mm) brick separation from thimble, minimum 24 gauge in thickness, having clay liner to combustibles.
ADDITIONAL MOBILE HOME REQUIREMENTS — The end of this duct must be equipped with a screen which prevents rodents from infiltrating. WARNING: DO NOT INSTALL IN SLEEPING — The end of this duct must be kept free of leaves, ROOM. snow, ice, or other debris that could restrict air supply when the appliance is in operation.
Page 12
LINED MASONRY CHIMNEY INSTRUCTIONS & DIAGRAM This stove is designed to be vented through a masonry chimney which conforms to local building codes, fire codes, and latest edition of NFPA 21 1 US or CAN/ CSA-B365. 1. If the connection piping from the stove to a Wall masonry chimney is made through a combustible Termination...
OPERATION • Do not use the pellet sediment & debris at the bottom of the pellet container. THEORY OF OPERATION • Store pellets in sacks, made of environmentally 1. Combustion occurs in the fire pot, supported by neutral or biologically degradable plastic or from air introduced to and under the fire pot.
Page 14
OPERATING PRECAUTIONS • Cleaning Cycle: The firepot draws dust, ash, & remnants out. WARNING: HOT WHILE IN OPERATION. DO • Feeding Cycle: Pellets will be transported from the NOT TOUCH THE STOVE. KEEP CHILDREN, Pellet Hopper into the fire pot by the auger. This CLOTHING AND FURNITURE AWAY.
MINIMIZING CREOSOTE FORMATION Step 7. Make sure that your device is connected to the See “MAINTENANCE” on page 18 for an explanation wifi network which you want the stove to be of Creosote formation and removal. To slow the build connected to.
WIFI CONTROLS Once connected to the stove (See step 13 of Wifi Connection) you an remotely monitor and adjust the operation of the stove. See below for explanation: • Device Name: it is possible to rename the stove, so that if you have multiple stoves set up for operation you can more easily differentiate between while using the smart stove application.
PS60WTS, PS130WTS, AND PSBF66WTS MULTI FUNCTION CONTROLS Wireless Connection Rate Select Auger Lock Screen Display Scheduling Screen Desired Temperature Settings Room Temperature Temperature Status Power Figure 18a Mounted Multi Function Display Panel Figure 18b User Menu Mounted Button Functionality: Normal Operation Lock Screen Power •...
CLEANING: GLASS MAINTENANCE This wood heater needs periodic inspection and repair WARNING: DO NOT CLEAN GLASS WHEN for proper operation. It is against federal regulations HOT. to operate this wood heater in a manner inconsistent Though the circulation of air across the glass reduces with operating instructions in this manual.
Page 19
On each side of the stove there are two access covers creosote. To clean the exhaust venting system insert that can be removed by removing the fastening screws. an appropriate sized cleaning brush into the pipe to See Figures 21, 24 and 25. Turn off the stove, allow loosen and remove any ash or debris build up.
Page 20
REPLACING: AUGER SYSTEM WARNING: SUBSTITUTING ALTERNATE MATERIAL MAY SHATTER GLASS AND CAUSE INJURY. REPLACING: SEALING GASKETS Over time the sealing gaskets along the glass, door, or ash drawer may lose their rigidity. These seals are essential for providing a seal which allows the stove to operate safely.
Page 21
REMOVING BACK AND SIDE PANEL REPLACING: EXHAUST BLOWER Unplug the heater. Disconnect any wiring leading to the Exhaust Blower. Remove the wing nuts holding the Exhaust Blower plate to the blower housing. Slowly remove blower and replace with new one. Replace wing nuts and wiring.
Page 22
ERROR CODES NOTE: IN THE EVENT OF A POWER FAILURE (ERROR CODE E7), A SMALL AMOUNT OF SMOKE MAY BE EMITTED. THIS LASTS 3 TO 5 MINUTES AND DOES NOT REPRESENT A SAFETY RISK. CAUTION: IF OVERHEATING HAS OCCURRED (ERROR CODES E5 AND E6), THEN AN INSPECTION, MAINTENANCE, AND/OR CLEANING MUST OCCUR BEFORE THE STOVE CAN SAFELY BE OPERATED AGAIN.
Page 23
ERROR CODES CONTINUED 1. Check wires and connection points. ESC2 Short circuit at temperature sensor #2. 2. Replace Motherboard. 1. Check wires and connection points. ESO2 Open circuit at temperature sensor #2 2. Replace Motherboard. 1. Check wires and connection points. ESC3 Short circuit at temperature sensor #3 2.
Page 24
TROUBLESHOOTING CONTINUED SYMPTOM CAUSE SOLUTION No fuel in Pellet Add Fuel to Pellet Hopper. Hopper. During operation, besides 1. Unplug the unit so that it will not start suddenly the Lighting phase, the and then unblock the auger. Auger is blocked, auger is not filling the firepot 2.
Page 25
TROUBLESHOOTING CONTINUED SYMPTOM CAUSE SOLUTION No fuel in Pellet Add Fuel to Pellet Hopper. Hopper. 1. Unplug the unit so that it will not start suddenly and then unblock the auger. Auger is blocked 2. Check that the auger is not blocked. If it is or jammed or blocked, remove the cause of the jamming.
WIRING DIAGRAM NOTE: IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 105 °C AND RATED FOR 600V Grand Teton Wood Pellet Fire Stove Operating Instructions and Owner’s Manual...
Page 27
Grand Teton Wood Pellet Fire Stove Operating Instructions and Owner’s Manual...
Page 28
Grand Teton Wood Pellet Fire Stove Operating Instructions and Owner’s Manual...
SERVICE PARTS MODEL PSBF66WTS NOTE: NOT ALL PARTS AVAILABLE. FOR QUESTIONS CONTACT MANUFACTURER. WARNING: FAILURE TO POSITION THE PARTS IN ACCORDANCE WITH THESE DIAGRAMS OR FAILURE TO USE ONLY PARTS SPECIFICALLY APPROVED DESCRIPTION DESCRIPTION WITH THIS STOVE MAY 66632 Top Cover 66642 Rear Cover RESULT IN PROPERTY...
Page 30
This Warranty gives you specific legal rights, and you may have other rights which vary from state to state. Mr. Heater Inc. reserves the right to make changes at any time, without notice or obligation, in colors, specifi- cations, accessories, materials and models.
Page 31
DANS VOTRE LOCALITÉ (AUTORITÉS DE PRÉVENTION DES INCENDIES, SERVICE DE LA CONSTRUCTION MUNICIPAL, ETC.). RESPECTEZ TOUS LES CODES DE LA CONSTRUCTIONS LOCAUX. Mr. Heater une filiale de Enerco Group Inc. 4560 West 160th st Cleveland, Ohio 44135 1-866-740-2497 66699 REV C...
Page 32
AVERTISSEMENTS GÉNÉRAUX DE DANGERS : AVERTISSEMENT : NE PAS SE CONFORMER AUX PRÉCAUTIONS ET DANGER D’INCENDIE, DE BRÛLURE, D’ÉMANATIONS INSTRUCTIONS FOURNIES PEUT RÉSULTER EN UN ET DE DÉFLAGRATION. GARDER LES MATIÈRES COMBUSTIBLES SOLIDES TEL LES MATÉRIAUX DÉCÈS DE PERSONNE OU DES BLESSURES GRAVES DE CONSTRUCTION, LE CARTON OU LE PAPIER À...
SPÉCIFICATIONS de modèle PS60WTS PS130WTS PSBF66WTS DIMENSIONS Poids du poêle 90 (198) 100 (221) 120 (265) [kg (lb)] Dimensions du poêle 59,7 x 55,2 x 84,5 61,0 x 62,2 x 92,7 66,5 x 62,3 x 77,2 prof.x larg.x haut. [cm (po)] (23,5 x 21,75 x 33,25) (24,0 x 24,5 x 36,5) (26,2 x 24,5 x 30,4)
COMMENCER Clés Allen (x2) Panneau d’affichage Pot de feu Couvrir Cordon d’alimentation électrique KIT D’ACCESSOIRES Tuyau flexible Limite de Collier de serrage Adaptateur d’air Outil de nettoyage terminaison et frais Des vis (x4) CE DONT VOUS AVEZ BESOIN (NON FOURNIS) OUTILS REQUIS ÉQUIPEMENT DE SÉCURITÉ...
MONOXYDE DE CARBONE PRÉCAUTIONS DE SÉCURITÉ AVERTISSEMENT : ÉTABLISSEZ UNE RÉACTION DE SURVIE EN SI UTILISÉ SANS COMBUSTIBLE ET AÉRATION CAS D’INCENDDIE. COMMUNIQUEZ AVEC LE ADÉQUATS, CE POÊLE PEUT PRODUIRE UN SERVICE D’INCENDIE LOCAL POUR OBTENIR DES EXCÈS DE MONOXYDE DE CARBONE, UN GAZ RENSEIGNEMENTS ET UNE PROCÉDURE D’ACTIONS À...
DISTANCES DE DÉGAGEMENT DES • Qu’il y ait un dégagement minimum de 330 mm (13 po) de chaque coté de l’appareil. MATÉRIAUX COMBUSTIBLES • Qu’il y ait un dégagement minimum de 51 mm (2 po) à Les distances de dégagement indiquées ci-dessous l’arrière de l’appareil.
Page 37
DÉBALLAGE 1. Sortir le poêle du carton d’emballage. 2. Retirer tout le matériel protecteur placé sur le poêle pour l’expédition. 3. Inspecter le poêle pour détecter tout dommage d’expédition. Si des dommages sont détectés, appelez le fabricant sur le champ-au 1-866-740-2497. ATTENTION : TOUTE PIÈCE ENDOMMAGÉE POURRAIT COMPROMETTRE LE FONCTIONNEMENT Figure 3 Pot...
à combustion de vos votre poêle, veuillez contacter soit : quartiers et possiblement causer une condition dangereuse. Le fabricant Mr. Heater Company à 1-866-740-2497 • Fins L’approvisionnement d’air de combustion de l’extérieur de semaine/après les heures d’ouverture 423-488-6316 •...
Page 39
• Cheminée de maçonnerie certifiée ICBO (International EXIGENCES ET ASSEMBLAGE DES RACCORDS Conference of Building Officials) pour les poêles à ATTENTION : LE TUYAU DE RACCORDEMENT DE combustible solide. CHEMINÉE NE DOIT PAS TRAVERSER LE GRENIER CAPUCHON D’ÉVENT OU LE TOIT, OU TOUT GARDE-ROBE OU ARMOIRE •...
Page 40
TECHNIQUES DE TRAVERSÉE DE MUR APPROUVÉES NFPA 211 (É-U SEULEMENT) Dégagement de cheminée minimum NFPA 211 (É-U SEULEMENT) Dégagement minimum de la cheminée des surfaces aux montants de soutien en acier et des de brique ou de matériau combustible : 51 mm (2 po) matériaux combustibles : 51 mm (2 po) Gaine à...
EXIGENCES SUPPLÉMENTAIRES POUR MAISONS compromettant une aération adéquate. • Une canalisation permanente d’admission d’air frais MOBILES pour entretenir la combustion devra être installée en répondant aux exigences suivantes : AVERTISSEMENT : NE PAS LOCALISER DANS — La canalisation devra être totalement métallique LES CHAMBRES À...
Page 42
INSTRUCTIONS ET SCHÉMA DE CHEMINÉE DE MAÇONNERIE AVEC CONDUIT DE FUMÉE Ce poêle est conçu pour une évacuation par une cheminée de maçonnerie conforme au code du bâtiment et code des incendies locaux ainsi qu’aux dernières éditions des normes NFPA 211 aux États-Unis ou CSA-B365 au Canada. 1.
FONCTIONNEMENT • Ne pas utiliser les sédiments et débris au fond des contenants de grenailles. THÉORIE DE FONCTIONNEMENT • Entreposer les grenailles dans des sacs à deux ou trois 1. La combustion se produit dans le pot du poêle qui est couches de papier (comme ceux des sacs de ciment) alimenté...
Page 44
PRÉCAUTIONS POUR LE FONCTIONNEMENT • Cycle de nettoyage : Le pot de combustion est nettoyé des cendres, poussières et résidus accumulés. AVERTISSEMENT : BRÛLANT DURANT LE • Cycle d’alimentation : Les grenailles passeront de la FONCTIONNEMENT. NE PAS TOUCHER.LE trémie au pot de combustion par l’entremise de la POÊLE.
qu’elles correspondent aux exigences de votre poêle telles Étape 5. Vous pouvez maintenant définir un mot de passe unique pour votre appareil dans le champ « Définir qu’indiquées à la page 3. le mot de passe » et cliquer sur le bouton « Terminé COMMENT MINIMISER LA FORMATION DE CRÉOSOTE ».
COMMANDES WI-FI Une fois connecté au poêle (voir l’étape 11 de Connexion Wi-Fi), vous pourrez ajuster et surveiller le fonctionnement du poêle à distance. Voir les explications ci-dessous : • Nom du dispositif : Il est possible de changer le nom du poêle pour différencier l’appareil commandé...
ENTRETIEN NETTOYAGE : VITRE Pour un bon rendement de fonctionnement ce poêle à AVERTISSEMENT : NE PAS NETTOYER LA grenailles de bois nécessite un entretien périodique. Toute VITRE LORSQUE CHAUDE. opération ne respectant pas les directives du présent Guide Bien que la circulation d’air sur la porte vitrée réduit du propriétaire contrevient à...
Page 49
Un panneau d’accès se trouve de chaque côté du poêle qui fonctionnement. Pour nettoyer le système d’aération, insérez peut être déposés en dévissant ses vis de fixation. Voir les une brosse de nettoyage de dimension appropriée dans le figures 21, 24 et 25. Éteindre le poêle, le laisser se refroidir tuyau pour dégager et retirer toute cendre ou accumulation et le débrancher avant tout démontage et nettoyage.
Page 50
REMPLACEMENTS : SYSTÈME DE TARIÈRE AVERTISSEMENT : L’UTILISATION DE MATÉRIAU SUBSTITUT POURRAIT BRISER LA VITRE ET CAUSER DES BLESSURES. R EMPLACEMENTS : JOINTS D’ÉTANCHÉITÉ Au fil du temps, les joints d’étanchéité autour de la vitre, de la porte et du tiroir de cendre pourraient perdre de leur rigidité.
Page 51
RETRAIT DES PANNEAUX ARRIÈRE ET LATÉRAUX REMPLACEMENTS : VENTILATEUR D’ÉCHAPPEMENT Débrancher le poêle. Déconnecter tout câblage raccordé au ventilateur d’échappement. Retirer les écrous à oreilles maintenant la plaque de l’ensemble sans son logement. Retirer lentement le ventilateur et le remplacer par le nouveau. Fixer avec les écrous à...
Page 52
CODES D’ERREUR REMARQUE :DANS L’ÉVENTUALITÉ D’UNE PANNE DE COURANT (CODE D’ERREUR E7), UNE FAIBLE QUANTITÉ DE FUMÉE POUR- RAIT ÊTRE DÉGAGÉE. CECI DURERA DE TROIS À CINQ MINUTES ET NE REPRÉSENTE PAS UN DANGER. ATTENTION : S’IL S’EST PRODUIT UNE SURCHAUFFE (CODES D’ERREUR E5 ET E6), ALORS UNE INSPECTION, ENTRETIEN ET/OU UN NETTOYAGE DEVRA ÊTRE EFFECTUÉ...
Page 53
CODES D’ERREUR (SUITE) 1. Vérifier les fils et les points de raccordement. Capteur de température n 2 en ESO2 2. Remplacer la carte mère. circuit ouvert Capteur de température n 1. Vérifier les fils et les points de raccordement. ESC3 court-circuité...
Page 54
DÉPANNAGE (SUITE) SYMPTÔME CAUSE SOLUTION La trémie est vide. Ajouter des grenailles dans la trémie. 1. Débrancher l’unité de sorte qu’il ne se produise La tarière n’alimente pas le pas de démarrage inattendu et dégager le blocage pot de combustion durant La tarière est de la tarière.
Page 55
DÉPANNAGE (SUITE) SYMPTÔME CAUSE SOLUTION La vitesse d’alimentation n’est 1. Diminuer la vitesse du ventilateur pour diminuer le Pas assez de grenailles dans pas suffisante pour taux de combustion. le pot de combustion. soutenir ce taux de 2. Augmenter la vitesse d’alimentation. combustion.
SCHÉMA DE CÂBLAGE REMARQUE : SI DES FILS QUELCONQUES DOIVENT ÊTRE REMPLACÉS ILS DEVRONT CORRESPONDRE AUX SPÉCIFICATIONS DE CÂBLAGE ORIGINAL DE TEMPÉRATURE NOMINALE DE 105 °C AVEC ISOLANT DE CLASSE DE 600 V Grand Teton Poêle à grenailles de bois Guide du propriétaire et intructions d’utlisation...
Page 57
Grand Teton Poêle à grenailles de bois Guide du propriétaire et intructions d’utlisation...
Page 58
Grand Teton Poêle à grenailles de bois Guide du propriétaire et intructions d’utlisation...
MODÈLE PSBF66WTS PIÈCES DE SERVICE REMARQUE : LES PIÈCES NE SONT PAS TOUTES EN MAGASIN. POUR TOUTE QUESTION, COMMUNIQUEZ AVEC LE FABRICANT. AVERTISSEMENT : NE PAS POSITIONNER LES PIÈCES SELON CES SCHÉMAS OU NE PAS UTILISER EXCLUSIVEMENT LES PIÈCES SPÉCIFIQUEMENT APPROUVÉES POUR CE POÊLE POURRAIT RÉSULTER EN DES DOMMAGES MATÉRIELS OU DES BLESSURES DESCRIPTION AUX OCCUPANTS.
Page 60
Si une pièce est endommagée ou manquante, appelez notre Service de soutien technique au 1-866-740-2497. Adresser toute demande de compensation de garantie à : Service Department, Mr. Heater, Inc., 4560 W. 160TH ST., CLEVELAND, OHIO 44135 U.S.A. Indiquez votre nom, adresse et numéro de téléphone, le numéro de modèle et le numéro de série de votre produit et décrivez les détails concernant la demande de compensation.
Need help?
Do you have a question about the Grand Teton PS60WTS and is the answer not in the manual?
Questions and answers
I have a Grand Teton TS 130 by Mr heater it's a Wi-Fi connection with a Wi-Fi computer screen on it the power button keeps going off and I have to go manually push the power button back on to get it to start back up what could be wrong with it it does it throughout the day and overnight
The power button on the Mr. Heater Grand Teton PS60WTS may turn off due to a high temperature sensor failure (sensor located below the pellet hopper), power failure, or issues such as a short or open circuit at temperature sensors. These conditions can trigger error codes like E7, ESC1–ESC3, or ESO1–ESO3, causing the stove to shut down.
This answer is automatically generated
My pellet stove keeps shutting off throughout the day or in the middle of the night and I have to manually turn it back on on the screen from the Wi-Fi what could be the problem
The Mr. Heater Grand Teton PS60WTS pellet stove may shut off unexpectedly due to the ECO 1 mode being enabled. In ECO 1 mode, the stove shuts off when the desired temperature is reached and restarts when the room cools to a preset level. Additionally, improper cleaning and maintenance—such as a blocked fire pot, ash drawer, or air passageways—can also cause shutdowns. The stove must also be turned off twice every 24 hours for cleaning if used continuously.
This answer is automatically generated