Kelvin RH015 Installation, Operation And Maintenance Manual

Remote horizontal air cooled heat exchangers

Advertisement

Quick Links

INSTALLATION,
OPERATION AND
MAINTENANCE MANUAL
FOR MODEL RH
REMOTE HORIZONTAL
AIR COOLED
HEAT EXCHANGERS
5050 South National Dr.
Knoxville, TN 37914
Telephone: (317)-227-2929
1

Advertisement

Table of Contents
loading

Summary of Contents for Kelvin RH015

  • Page 1 INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR MODEL RH REMOTE HORIZONTAL AIR COOLED HEAT EXCHANGERS 5050 South National Dr. Knoxville, TN 37914 Telephone: (317)-227-2929...
  • Page 2: Table Of Contents

    MODEL RH REMOTE HORIZONTAL AIR COOLED HEAT EXCHANGERS TABLE OF CONTENTS TOPIC PAGE Model Nomenclature ..................Inspection ....................... Handling and Moving ..................Location ......................Assembly of Unit ................... Electrical Wiring .................... Piping ......................Start-Up and Operation .................. Freeze Protection ................... Maintenance ....................
  • Page 3: Model Nomenclature

    MODEL NOMENCLATURE Motor HP Motor RPM A - 870 D - 730 Horizontal B - 1160 E - 970 C - 1750 F - 1450 RH 035 – 2B – 4P Round Tube Number of Passes Nominal Coil Face Area, FT² INSPECTION Upon receiving the equipment, all items should be checked against the bill of lading to ensure that everything has been received.
  • Page 4 Fig. 1b Lifting an RH module with slings.
  • Page 5: Location

    NET DRY WEIGHT – LBS. (Kg.) Model Number Module Weight Total Weight RH015 475 (215) 475 (215) RH025 950 (432) 950 (432) RH035 1200 (544) 1200 (544) RH045 1475 (669) 1475 (669) RH055 950 (431) 1900 (862) RH070 1200 (544)
  • Page 6: Electrical Wiring

    After the legs have been attached and the unit has been moved into place check to make sure the coil is level to ensure proper coolant drainage. If it is level bolt the unit to its foundation. ELECTRICAL WIRING The electrical installation should be in accordance with National Electrical Code, local codes and regulations.
  • Page 7: Maintenance

    MAINTENANCE The RH Models are relatively maintenance free. Electric motor bearings are prelubricated and should be lubricated as shown below. Relubricate Intervals The following intervals are suggested as a guide. Hours of Service Per Year Suggested Relube Interval 5000 Every 5 years Continuous Once a year Normal Application...
  • Page 8: Replacement Parts

    REPLACEMENT PARTS If it becomes necessary to order parts, please mention all identifying numbers, such as model number or part number as found on the Kelvion nameplate.