TROUBLE SHOOTING
Symptom
Possible Cause
The hot or cold water is very
Pinched tubing
slow to turn on
The hot or cold water is very
Pinched tubing
slow to shutoff or will not
shutoff
Noise from the Valve Blocks
The Valve Block may have
while the water is running
excessive debris trapped
under the Filter-screen
Noise from the Valve Blocks
Air in the system
when turning water on and
off
For further information: www.tapmaster.ca or call 800-791-8117
FIVE YEAR LIMITED WARRANTY
Congratulations on your purchase of TAPMASTER Hands Free Faucet Controller!
TAPMASTER products are thoroughly tested before shipment and are warranted to be free of
defects in material and workmanship for five years from the date of original purchase. The sole
obligation of Tapmaster Incorporated under the warranty is to provide replacement parts or at its
option to repair the defective product or to provide the replacement product. Replacement parts
furnished in fulfillment of this warranty are warranted only for the unused portion of the original
warranty. Labor and shipping charges are not included.
Warranty conditions
- The five year warranty is subject to exclusions and limitations as stated
Warranty extends only to defects which occur during normal use and intended applications and
does not extend to damage to products or parts resulting from alteration, repair, modification or
faulty installation. This warranty does not cover damage resulting from water borne debris or
from media other than clean potable water. Tapmaster Incorporated makes no other express
warranty on this product, all implied warranties including any implied warranty of merchantability
and fitness for a particular purpose are hereby disclaimed and excluded. In no event shall Tap-
master Incorporated be liable for special, incidental or consequential damages resulting from the
use of this product or arising from breach of warranty or contract, negligence, loss of time,
inconvenience or loss of use of equipment.
Tapmaster Incorporated
3-1470 28th Street NE
Calgary, AB Canada
T2A 7W6
Remedy
Check control tubing (yellow
and blue lines)
Check control tubing (green
and blue)
Service the Valve Blocks
Operate the pedal on and off
rapidly to clear air from the
valves.
below:
PH: 800-791-8117
Rev 3.0
FAX: 403-275-5928
Web: www.tapmaster.ca
E-mail: info@tapmaster.ca
-
-
4
INSTALLATION INSTRUCTIONS: EURO Models 1770, 1771, 1775 & 1776
CAUTION - READ BEFORE INSTALLATION
Tapmaster Incorporated will not be held liable for damage to property or persons resulting from improper installation of this product
any part of the installation process, please contact us for assistance or consult a professional tradesperson before installation.
Water lines must be flushed prior to installation
Do not install if control tubes are damaged in any way
Control tubes are pressurized after installation. Do not
expose tubing to excessive heat, unsealed chemicals, or
physical damage
This illustration shows a typical installation for the Euro Model 1770 series
Tapmaster. The valve blocks are connected in-line on the hot and cold water
supplies with 3/8" compression fittings. The Euro foot activator is mounted on
the cabinet toe kick with the control tubing routed from the foot activator
through the cabinet base to the hot and cold water supplies to make the con-
nections to the valve blocks.
Models 1771 and 1776 come with one valve block and are generally used on
tepid or single line water supplies. Models 1770 and 1775 come with two
valve blocks for standard hot and cold water lines. Installations will vary
according to the design of the cabinet, type of faucet and plumbing hardware.
In some cases, it may be simpler to connect the valve blocks at a mid-point
along the 3/8" supply tubing. In this case it will be necessary to obtain a 3/8"
x 3/8" compression connector
the inlet fitting into the water lines. Other plumbing arrangements may be
encountered where larger than 3/8" O.D. tube sizes are used. In these
situations reducing adapters
to install the Tapmaster.
Although Tapmaster will work with any faucet, faucets that have handles which give a reference
for flow and temperature are recommended. The Euro foot activator will fit cabinets with toe kicks
ranging in height from 3" (75mm) to 6" (150mm) and it is recommended to be vertically aligned
with the center of the faucet. The plastic probe part of the foot activator is cut to length to keep
the bottom of the probe approximately 1/2" to 1" above the floor.
OPERATION
Models 1770 and 1771 feature momentary operation only,
while Models 1775 and 1776 incorporate a lock on feature in
addition to momentary operation.
momentary mode
To operate the Tapmaster Euro in
the faucet open at the flow and temperature desired, push
the Euro probe foot activator in any direction for momentary
water flow, release to turn off.
continuous mode
For
, push the Euro probe foot activator
sideways to 45 degrees in either direction to lock on; push
activator back to vertical rest position to turn off. The locking
feature allows the operator to manually use the faucet for
such things as filling the sink, etc. It is not recommended for
repeated on/off operation. This feature has been
intentionally designed to require a deliberate thoughtful
motion on the part of the operator to prevent locking inad-
vertently.
Tapmaster does not alter the appearance of the faucet,
removable decal
therefore a
is provided which may be
located on any hard smooth surface near the faucet to alert
people to its method of operation.
CAUTION: it is possible for pets or small children to inadvert-
ently lock on the Tapmaster—simply leave the faucet closed. Never leave the drain stopper in the
closed position in any sink.
PATENT NUMBERS
CSA-B125.1-18
U.S. 5,505,227, 6,254,057,
ASME A112.18.1-2018
NFS/ANSI 61-2016
Canadian 2,109,684
NSF/ANSI 372-2016
European 0654628
International & Other Patents
DRINKING WATER
LOW LEAD CONTENT
.
If you are uncertain about
Use of substitute tubing voids manufacturer warranty and
liability
Do not expose valves to thread sealants/plumbers putty
Operating Range: 0 - 125 psi (8.6 bar) Max, 140° F
(60° C) Max
GENERAL
(available at most hardware stores)
(available at hardware stores)
must be obtained
, leave
6,382,585
Pending
to connect

Advertisement

loading

Summary of Contents for Tapmaster 1770

  • Page 1 CAUTION - READ BEFORE INSTALLATION Tapmaster Incorporated will not be held liable for damage to property or persons resulting from improper installation of this product If you are uncertain about any part of the installation process, please contact us for assistance or consult a professional tradesperson before installation.
  • Page 2 INSTALLING THE EURO PROBE INSTALLING THE VALVE BLOCKS GENERAL: The instructions below for mounting the Euro STEP #1 - Connect the control tubes from the euro actuator to the probe are for a typical installation and only a guideline. Sink/ Figure 5 valve block with the plastic sleeves provided as per the color-coded cabinet styles, toe kick heights and construction materials...

This manual is also suitable for:

177117751776