Ⅰ . Main Construction Data
Type
Rated Power
E120012
10W (1x10W)
E120014
20W (1x20W)
E120016
30W (1x30W)
Ⅱ . Safety Instructions
1. Before mounting and maintenance please make sure that the electrical supply has been switched off to
avoid electric shock.
2. The light must be earthed.
3. The power cord should be at least H05RN-F 3x 1.0 mm² thick waterproof cable
4. Replace the cracked protection glass immediately and use only original parts to substitute.
5. Connect the yellow/green wire of the connection supply cable to the connection block with earthing mark.
Mount the other wires into the connection block according to mark "N" and "L".
6. Before maintenance work, the power should be switched off. The maintaining should be done only by a
qualified electrician.
7. The light is only suitable for fixed mounting.
Ⅲ. Maintenance
CAUTION: The light source of lamp can not be replaced, please replace a whole new lamp if the light source
broken.
This marking indicates that this product should not be disposed with other household wastes throughout the
EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal,
recycle it responsibly to promote the sustainable reuse of material resources. To return your used device,
please use the return and collection systems or contact the retailer where the product was purchased. They
can take this product for environmental safe recycling.
Tempered
Weight
Glass
110x82x4mm
0.6 Kg
175x135x4mm
1.5 Kg
220x180x4mm
2.5 Kg
Maximum
Dimensions
projected area
2
0.01M
140x115x90mm
2
0.02M
163x181x115mm
2
0.04M
226x205x135mm
Remark
Electric shock protection class:Ⅰ
Ingress protection class: IP65
Rated voltage: 220-240V~ 50Hz
Max height: <3M