PowerStation, PS6 Series
INSTALLATION, FREE-STANDING MODEL
The unit is shipped in the upside-down position, casters are factory installed, 2 models available,
All items below are shipped in a separate box:
Model
Ships with:
PS625-2370-0
(2) F022 HEPA filters, (6) AG259 YELLOW filter bags, (4) Galv Filter Separators,
O&M Manual, Hose and fittings are added separately depending on application.
PS625-23AZ6GH
(2) F022 HEPA filters, (6) AG149 WHITE filter bags, (2) Galv Filter Separators, O&M
Manual, (2)inlet plates(3x1.5"dia),50ft 1.5"dia suction hose, 240v PowerCord(#E302),
Foot-pedal (AA175),
(6) Rubber hose fittings, (6) 2"wide x ½"thick gaskets for rubber hose fittings:
Your option to install unit on (6) stationery rubber feet or (4) mobile casters (install 2
lockable casters in front)
1) Install Rubber feet or casters
2) Open filter door, remove plastic around HEPA filter, install HEPA filter, Grating and filter bags
3) Plug Power Cord to a grounded 240-volt wall outlet
4) Connect to individual workstations
SYSTEM IS MORE EFFICIENT WHEN CONNECTING EACH WORKSTATION INDIVIDUALLY
START-UP
1) Plug the unit into a 220-240v wall outlet with the cord provided (socket is on side of unit)
2) After 10seconds, switch ON using RED POWER button on control panel to ensure unit STARTS
"System ON" LED illuminates, indicates unit is operating
2) Press POWER button again to switch unit OFF
3) You are now ready to operate
4) Install Foot-Pedal (#AA175) into the db9 (9-pin socket on side of unit) to start/stop unit remotely
If: "System ON" LED is OFF (indicates unit NOT operating)
If: "Remote/Standby" LED flashes (indicating unit is in WAITING MODE)
---------------------------------------------------------
30 Hymus Boulevard, Montreal, Quebec, H9R 1C9
Operations & Maintenance Manual
Connect to 1.5" dia: use hose directly
Connect to 2" dia: use Rubber Hose fittings to connect
Connect to 2.5" or 3"dia: use ½" thick gaskets around Rubber hose Fittigns to make
up the dimension
Tel.: (514) 630-4444 Fax: (514) 630-4454 website:
Engineers Of Clean Air
PS6 is shipped on a
pallet, in an Upside-
Down Configuration
Accessories shown
on top are shipped in
a box, placed on top
of the unit
--------------------------------------------------------
www.quatroair.com
QUATRO
Air Technologies Inc.
info@quatroair.com

Advertisement

loading

Summary of Contents for Quatro PowerStation PS6 Series

  • Page 1 QUATRO Air Technologies Inc. Operations & Maintenance Manual PowerStation, PS6 Series PS6 is shipped on a pallet, in an Upside- Down Configuration Accessories shown on top are shipped in a box, placed on top of the unit INSTALLATION, FREE-STANDING MODEL...
  • Page 2 QUATRO Air Technologies Inc. OPTIONAL ON-OFF Unit can be switch ON-OFF at a 2 location. To do this, you can purchase: A- db9 Cable Signal Splitter (#AE686) B- second Foot-pedal (#AA175) or Hand-Switch (#AA375) This will split your Foot-pedal/Hand-Switch signal into 2 inputs. To extend the length of your foot-pedal or Hand-Switch cable, you can purchase Male-Female DB9 cable at your local electronics store.
  • Page 3 QUATRO Air Technologies Inc. SAFETY PRECAUTIONS Carefully read instructions in this manual before operation (keep manual as it contains information for proper operation and maintenance). Keep all fastening hardware tight to ensure that the unit is in safe working condition. Familiarise yourself with the way in which the special filter is removed, installed, and serviced.
  • Page 4: Blower Maintenance

    QUATRO Air Technologies Inc. Filter Bags (6 required) AG149, kit of 6 WHITE bags AG259-06, kit of 6 YELLOW bags HEPA Filter 2 X (F022) located at bottom below the filters, behind front access door (remove plastic around HEPA filter before starting unit) WARNING: DO NOT OPERATE UNIT UNLESS ALL FILTERS ARE IN PLACE.
  • Page 5: Replacement Parts List

    QUATRO claims no warranty as to merchantability or as to the fitness of the merchandise for any particular use and shall not be liable for any loss or damage. No person, firm or corporation is authorised to assume for QUATRO any other liability in connection with the sale of these goods.
  • Page 6 Standby Signal Of Equipment LED 5 Fading Shutdown Delay Quatro System Continues To Run For A Short Period To Remove All Debris (L5) IN-OUT From Work Area Flashing Unit Is In Standby Waiting For Remote Switch To Close (Turn On) OR To Receiving Remote...