Download Print this page
BAR-BE-QUICK inStove BS1251 Installation And Operating Instructions

BAR-BE-QUICK inStove BS1251 Installation And Operating Instructions

Inset solid fuel roomheater

Advertisement

Quick Links

INSTALLATION AND OPERATING INSTRUCTIONS
LEAVE THIS DOCUMENT WITH THE HOUSEHOLDER!
13229
Read these instructions! Use only recommended fuels!
This document, when completed by the installer, constitutes a 'Hearth Notice' for purposes of the England and Wales
Building Regulations 2000 . It must be left with the householder and placed where it can easily be found.
APPLIANCE SERIAL NUMBER:
INSTALLED AT LOCATION:
BY:
SIGNED:
Who certifies that this installation is safe, has been demonstrated to the
householder, conforms with current building regulations and with these
TO FIND A QUALIFIED INSTALLER, FUEL SUPPLIER or CHIMNEY SWEEP, CONTACT:
UK: The Solid Fuel Association, 7 Swanwick Court, Alfreton, Derbyshire DE55 7AS Tel:0845 -601-4406 www.solidfuel.co.uk
RoI: Irish Nationwide Fireplace Organisation, 162 Capel Street, Dublin 1 Tel:01-801-5959 www.fireplace.ie
Intermittent burning solid fuel roomheater for installation in masonry
fireplace with a single dedicated chimney.
Wood logs
Approx e iciency
50-60%
Nominal Output
2.0kW
Minimum air space
Back = 0mm, Sides + Top = 100mm
around fire
Minimum clearance to
Top: 400mm
combustible materials
All other faces: 250mm
DATE:
instructions
1
(revision 'a')
INSET SOLID FUEL
ROOMHEATER
FOR INSTALLATION IN
STANDARD BRITISH or IRISH
FIREPLACES CONFORMING TO
BS1251 & BS8303
Mineral fuel (Ancit)
50-60%
4.5kW
Flue Draught measured
on commissioning:
Pa
ins.wg
Fuel used on
commissioning

Advertisement

loading

Summary of Contents for BAR-BE-QUICK inStove BS1251

  • Page 1 (revision 'a') INSET SOLID FUEL ROOMHEATER FOR INSTALLATION IN STANDARD BRITISH or IRISH FIREPLACES CONFORMING TO BS1251 & BS8303 INSTALLATION AND OPERATING INSTRUCTIONS LEAVE THIS DOCUMENT WITH THE HOUSEHOLDER! Intermittent burning solid fuel roomheater for installation in masonry 13229 fireplace with a single dedicated chimney. Wood logs Mineral fuel (Ancit) Approx e iciency...
  • Page 2: Air Supply

    FITTING TO FLUE PIPE OR LINERS THIS APPLIANCE CAN PRODUCE POISONOUS A round flue-pipe adaptor (A) is available to connect to the Instove to GASES. IT, AND ITS FIREPLACE CAN BECOME standard 150mm flue pipe. The adaptor can be sealed to the pipe EXTREMELY HOT or liner with fire cement before inserting the stove in its fireplace, A fire-guard should be used if children or the infirm are...
  • Page 3: Check The Installation

    CHECK THE INSTALLATION ! SMOKE CONTROL: In certain areas special rules apply to reduce smoke nuisance. Check with your local authority about what fuels Once installed, light the fire, demonstrate it to the householder and are permitted. check that: • It burns controllably and does not emit fumes to the room WOOD only emits as much carbon to the atmosphere as the tree •...
  • Page 4: Maintenance

    HOUSEHOLD WASTES Some plastics give off toxic fumes when UNSUITABLE, BLOCKED OR UN-SWEPT CHIMNEY: The first burned and remember that batteries and aerosols explode! The requirement for correct operation is a sound chimney. Check the stove is not an incinerator, so only ever use the recommended requirements earlier in this document and in any case of doubt fuels and NEVER use liquid fuels in any form.

This manual is also suitable for:

Instove bs8303