➢ Transmitter Programming: RADIOEM101, RADIOEM102, RADIOEM103, RADIOEM104
The Opera Brand Transmitters can be used as either a 1-Door x 3-Button Transmitter or as a Multiple-Door Transmitter
(Commercial Sequence or SBC). Commercial Sequence or SBC settings depend on the operator programming settings.
The Transmitters can be re-programmed as needs change. Replacement Battery: 1x CR2032 (3V).
Transmitter
j
1.OPEN / STOP / CLOSE → Only Button
RADIOEM101
j
k
l
m
1.DOOR #1 → Top Left Button
2.DOOR #2 → Top Right Button
RADIOEM104
3.DOOR #3 → Bottom Left Button
4.DOOR #4 → Bottom Right Button
(1)
Each button acts separately as a 1-Button Transmitter.
Commercial Sequence or SBC Programming depends on the Operator Settings, please refer
to the Commercial Sequence or SBC Programming instructions, p. 4).
j
k
l
(Factory default for RADIOEM103SD)
1.OPEN → Top Button
RADIOEM102
2.CLOSE → Middle Button
Mini Key Chain
3.STOP → Bottom Button
j
k
(Factory default for RADIOEM102 &
l
1.DOOR #1 → Top Button
RADIOEM103
2.DOOR #2 → Middle Button
Single Door (SD) /
3.DOOR #3 → Bottom Button
Multiple Door
(MD)
(1)
Each button acts separately as a 1-Button Transmitter.
Commercial Sequence or SBC Programming depends on the Operator Settings, please refer
to the Commercial Sequence or SBC Programming instructions, p. 4).
1-800-361-2260
www.manaras.com
Rolling Code Transmitters - Series "100"
Rolling Code Transmitters - Series "100"
Specifications and Programming Instructions
Specifications and Programming Instructions
Modes and Functions
1-Door
1-Button Transmitter
(1)
4-Door
4 x 1-Button Transmitter
1-Door
3-Button Transmitter
3-Door
3 x 1-Button Transmitter
RADIOEM103MD)
Transmitter Programming
No initial programming is required.
The Transmitters are ready to be matched to the
(1)
Receiver of your choice, refer to section Transmitter
to Operator Matching (Pairing), p. 3.
1.Press and HOLD Buttons
The RED LED will
You have 15 sec. to complete the configuration or
you will need to restart.
2.Release Buttons
3.Press Button
4.The RED LED will stop
Programming is now complete.
1.Press and HOLD Buttons
(1)
The RED LED will
You have 15 sec. to complete the configuration or
you will need to restart.
2.Release Buttons
3.Press Button
4.The RED LED will stop
Programming is now complete.
1
j
l
and
for 5 sec.
BLINK.
j
l
and
.
j
.
blinking.
j
l
and
for 5 sec.
BLINK.
j
l
and
.
l
.
blinking.
TN1054 REV 2 - 2022/01/24