Technical Information
OEtroCom-2, OEtroCom-3, OEtroCom-Easy
Control panels
Remplace, remove or add an electronic PCB
Troubleshooting
JS
Make a PCB autodetection
1.
Autodetection allows the identification of the electronic PCBs which are on the appliance and
the correct operation of the system.
Perform an autodetection in the following cases:
-
Replacing an electronic PCB on a device
-
Removing or adding a PCB to a device
-
Cascade: replacing, removing or adding an electronic PCB on one of the devices.
-
One of the following error codes appears: H02.02, H02.03, H02.36, H02.37, H02.45,
H02.46,...
On OEtroCom-2 control panel
2.
1. If an error code is displayed: clear the error by pressing the RESET key,
2. Press the 2 right-hand keys to access the Installer Menu,
3. Enter the code 0012
4. If more than one electronic PCB is displayed: select the main PCB:
-
EHC-...
-
CU-GH-...
-
CU-OH-...
-
EEC...
5. Validate
6. Select autodetection parameter AD (at the end of the parameter list) and confirm
-
The autodetection is carried out,
-
The main screen is displayed again when the automatic detection is complete.
-
The mounted electronic PCBs are visible in the different menus.
BE- IT2698
N° ITOE0236-en
1/4
EN
29/09/2020
.
ITOE0236-en

Advertisement

loading

Summary of Contents for OERTLI OEtroCom-2

  • Page 1 One of the following error codes appears: H02.02, H02.03, H02.36, H02.37, H02.45, H02.46,… On OEtroCom-2 control panel 1. If an error code is displayed: clear the error by pressing the RESET key, 2. Press the 2 right-hand keys to access the Installer Menu, 3.
  • Page 2 On OEtroCom-3 control panel 1. Access the installer level : Select Enter code 0012 with the rotative button and confirm 2. Press key Advanced Service Menu 3. Select Auto Detect. 4. Select Confirm 5. Select Autodetection is carried out The display indicates « Performing autodetect…...
  • Page 3 On a OEtroCom-Easy control panel The error H02.36 is displayed if an electronic PCB has been removed, replaced or added: To start a PCB autodetection: 1. Access the installer level: • Press key • Select installer icon and confirm with the button •...
  • Page 4 Appliances in cascade In case of replacement, removal or addition of an electronic PCB on a device integrated in a cascade:  On OEtroCom-2 (follower boiler) : no action required.  On OEtroCom-3 (on master boiler): 1. Access the installer level: •...

This manual is also suitable for:

Oetrocom-3Oetrocom-easy