Carrier COMFORTLINK 48P2 User's Information Manual

Gas heating/electric cooling units

Advertisement

Quick Links

User's Information Manual
NOTE TO INSTALLER:
This manual should be left with the equipment owner.
WARNING: If the information in this
manual is not followed exactly, a fire or
explosion may result causing property
damage, personal injury or loss of life.
— Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch;
do not use any phone in your
building.
• Immediately call your gas supplier
from a neighbor's phone. Follow the
gas supplier's instructions.
• If you cannot reach your gas sup-
plier, call the fire department.
— Installation and service must be per-
formed by a qualified installer, service
agency or the gas supplier.
WARNING
Improper installation, adjustment, alteration, ser-
vice or maintenance can cause injury or property
damage. Refer to this manual. For assistance or
additional information consult a qualified installer,
service agency, or the gas supplier.
WARNING
Before performing recommended maintenance, be sure
main power switch to unit is turned off and lockout tag is
installed. Electrical shock could cause personal injury.
Your combination heating/cooling rooftop unit is equipped
with an automatic direct spark ignition system and induced-
draft power combustion blower.
WARNING
Burners will light automatically. Do not attempt to light by
hand; personal injury may result.
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Catalog No. 04-53480054-01
Printed in U.S.A.
Form 48P-1SO
48P2,P3,P4,P5030-100
Gas Heating/Electric Cooling Units
with COMFORTLINK™ Controls
TO LIGHT UNIT
1. Do not turn off the electrical power to unit without
first turning off the gas supply.
2. Before attempting to start the gas heating section,
familiarize yourself with all the procedures that must
be followed.
3. Never attempt to manually light the burners on the
unit with a match, lighter, or any other flame. If the
electric sparking device fails to light the burners, refer
to the shutdown procedures, then call your dealer as
soon as possible.
If you do not follow these instructions exactly, a fire or
explosion may result, causing property damage, injury, or
loss of life.
See Fig. 1 for location of gas valve(s). Refer to Fig. 2 while
proceeding with the following steps.
1. Turn off the unit demand for cooling or heating by using
the scrolling marquee. The scrolling marquee is located in
the control box at the compressor end of the unit.
ESCAPE
a. Push the
is shown.
b. Push the
lit.
ENTER
c. Push the
STOP.
ENTER
d. Push the
will flash.
e. Push the
YES and then push
locked off from heating, cooling or any operation.
The controls will still function and the display will
still operate.
2. Close the field-installed manual gas shutoff valve.
3. Turn off the electrical power to the unit using the optional
disconnect or the field-installed disconnect and lock off
using proper lockout and tag-out procedures.
4. Open the burner section hinged access door.
5. Move the switch on the gas valves to the OFF position
and wait 5 minutes.
NOTE: If this is the first installation of the unit, the gas
flue hoods must be installed before operating unit. These
must be installed for the unit to run properly.
6. Move the switch on the gas valves to the ON position.
7. Close the burner section hinged access door.
8. Turn on the electrical supply to the units.
9. Open the field-installed manual gas valve.
Pg 1
DANGER
key unit a blank display screen
key until the SERVICE TEST LED is
key. The display will show
key again. The NO/YES display
or
key to toggle the display to
ENTER
. The unit will be
4-09
Replaces: New

Advertisement

Table of Contents
loading

Summary of Contents for Carrier COMFORTLINK 48P2

  • Page 1 User’s Information Manual NOTE TO INSTALLER: This manual should be left with the equipment owner. WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. —...
  • Page 2 FLUE OUTLET GAS VALVE FLUE OUTLET GAS VALVE NOTE: High heat consists of sections 1 and 2. Low heat consists of section 1 only. 030-050 SIZES a48-8445a LIMIT SWITCH NO. 1 FLUE OUTLET SECTION 1 GAS VALVE LIMIT SWITCH NO. 2 NOTE: High heat consists of sections 1-3.
  • Page 3 MODE Run Status Service Test Temperature Pressures Setpoints Alarm Status Inputs Outputs ESCAPE ENTER Configuration Time Clock Operating Modes Alarms STEP 1 STEP 4 a48-8298 STEP 6 STEP 8 STEP 2 STEP 5 STEP 7 MODE Run Status Service Test Temperature Pressures Setpoints...
  • Page 4: To Shut Unit Off

    TO SHUT UNIT OFF WARNING 1. Do not turn off the electrical power to unit without first turning off the gas supply. 2. Never attempt to manually light the main burners on unit with a match, lighter, or any other flame. If the electric sparking device fails to light the main burners, refer to the following shutdown procedures.
  • Page 5 When replacing your unit filters, always use the same size and type of filter that was originally supplied by the installer. Units with outdoor air capability have a cleanable filter for the outdoor air. This filter should be checked annually and cleaned as necessary.
  • Page 6 POWER EXHAUST ACCESS DOOR (TYP BOTH SIDES) POWER EXHAUST OPTION POWER EXHAUST ACCESS DOOR (TYP BOTH SIDES) FILTER POWER ACCESS EXHAUST DOOR OPTION POWER EXHAUST ACCESS DOOR (TYP BOTH SIDES) FILTER POWER ACCESS EXHAUST DOOR OPTION GAS SECTION ACCESS ACCESS DOOR DOORS FILTER HOODS...
  • Page 7 Periodically check the condition of fan Fan and Belts — wheels and housings and belt tension. When service is neces- sary, call your dealer. Evaporator-Fan Motor, Condenser-Fan Motor and Combustion-Fan Motor — recommended. Bearings will not require lubrication for at least 5 years of normal operation.
  • Page 8: Regular Dealer Maintenance

    Complete Service Instructions can be found in the base unit Controls, Start-Up, Operation, Service and Troubleshooting literature. Copyright 2009 Carrier Corporation Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Catalog No. 04-53480054-01 Printed in U.S.A.