CEBEK AL-10 User Manual

CEBEK AL-10 User Manual

Alarm station

Advertisement

Quick Links

Station for alarm system. Device for the control and processing of the shot from Input, output, corresponding timings, out for
telephone indicators, input against manipulation, and optocoupled Input relays detection sensors.
It Includes relay, acoustic indicator and status leds for the count down of the activation/deactivation and shot.
T E CHNICAL CHAR ACT E R IST ICS
Power supply:12/24 V D.C.
Maximum consumption:80 mA.
Relay of a switched circuit:250 V./5A. maximum.
Alarm shot, Relay activation: 2 min.(Repeating the cycle up to the alarm disconnection).
Alarm activation (it can be selected): by Closing contacts or high level, (5 V.D.C.)./ Supplying the module
Alarm deactivation: Closing contacts or high level, (5 V.D.C.).
Shot alarm input: Optocoupled, external signal at high level, 12 V.D.C. a
Input against manipulation: Closing of contacts or high level, (5 V.D.C.).
Min./Max timing for input and output times: 2 scales can be selected (0 to 24 sec.), (24 to 50 sec.).
Shot output for auxiliary circuits: NPN open collector output, (100 mA. max.).
Indicators for available activation time, output and indicator of shot alarm:leds 3 mm.
Net weight:65 gr..
Length x Width x Deep:87,5 x 72 x 30 mm.
Operating temperature:-25 ºC up to +55 ºC.
Rules: In accordance with 89/336/CEE Electromagnetic compatibility rule and its 32/31/CEE and 93/68/CEE modifications. RoHS free.
INST AL L AT ION
Power supply.
The connexion has to be done on the "Power" input. Respecting the polarity, the AL-1 circuit requires a 12 VDC power supply correctly filtered. We
recommend you to use a short circuit power supply with low ripple level, as our FE-103 or FE-503 power supplies, which have been developed to
perfectly answer to the circuit needs. Do never use transformer or rectifier to avoid to damage the circuit.
Note: Install a fuse and a switch has it is indicated on the schedule. Both are necessary for the module's protection as well as for your own safety, as
it is required by the "CE" regulations. Consult the corresponding power supply's instruction manual.
Control inputs.
The module has 3 inputs. The length of the cable used in for their connexion has to be as short as possible. If the distance is superior to 50 cm, it will
be necessary to use shielded cable, connecting the braid to the corresponding terminal indicated with the ground symbol. In any case, the maximum
length will be to 2m.
Activation of Start and Box inputs.
indicated with the ground symbol. The activation can be also done through an external voltage signal. In such case, the signal have to be 5. DC.
perfectly stabilized, with the negative connected to the circuit's common negative, terminal with the ground symbol. The activation will be done if the
signal is equal to 0 V.
Activation of the "Alarm-In" shot input.
receives a 12 V.D.C signal. It does not allow the activation closing both terminals, but an external 12 V.D.C signal connected according to the polarity
indicated on the circuit.
The input Against Manipulating
is like to 5 V. Its operation for a switch that controls the closure of the carrier of the alarm, if it is opened without disconnecting the alarm previously,
the switch will release the two contacts for the Box input fire alarm, regardless of the expected time of entry.
Salida O_SiG.
The "O_Sig" output is activated when the relay of the circuit do it, that mean when the alarm is activated, supplying to the output a NPN transistor
signal to opened collector, destined to the activation (for instance), of Cebek telephone dialling circuits, like DA-08.
When it has happened an intrusion without deactivation code, the relay and the "O_Sig" output are activated. In the drawing, there is a connexion of
this output with a dialling circuit to warn about the intrusion, calling to the pre-assigned number, (DA-08 module).
R elay Connexion. T o control sirens or other alarm indicators.
The relay connection does not have to be contemplated like an output, it does not supply voltage. Electrically insulated from the rest of the
circuit, its function is to open or to close its contacts to allow or to interrupt the cross of an electrical signal, like a standard switch with a bulb.
The relay has three terminals: Common, Normally opened in rest (NOT), and Normally closed in rest, (NC).
You have to directly connected one of both load supply cables to the same one, the other one has to be inserted through contacts of the relays,
typically between the Common and NO, as it is specified in the fig 1, internally the relay will cut or valid the electric flux of the cable.
Fig 1. How to connect the load
Connection of the load in D.C.
Normally closed, (Nc)
Normally Open, (No)
Load connexion.
The activation of these two inputs is done closing the corresponding terminal with the common negative terminal
The activation and corresponding alarm shot, (if it is not firstly deactivated), will be done when the input
is activated when released the union of its two terminals, (Box and ground), or via external signal of 5 VDC, when this
Common
Load,
Device
Connection of the load in A.C.
Common
Normally closed, (Nc)
Normally Open, (No)
Load connexion.
AL-10
Alarm station
Load,
Device
1/4

Advertisement

loading

Summary of Contents for CEBEK AL-10

  • Page 1 The "O_Sig" output is activated when the relay of the circuit do it, that mean when the alarm is activated, supplying to the output a NPN transistor signal to opened collector, destined to the activation (for instance), of Cebek telephone dialling circuits, like DA-08.
  • Page 2 AL-10 Alarm station INST AL L AT ION , (continued) Considerations of the relay. Specially with inductive loads, a relay output can produce a fluctuation, flashing, etc,.. or an incorrect operating mode. In such case, you have to install an anti-spark circuit between the two relay contacts used in the connexion, that will assure the absorption the current peak generated by the mentioned problem.
  • Page 3 AL-10 Alarm station OPE R AT ING MODE , (continued) Activation/ Deactivation The alternative between On and Off, is done each time you press Start, allowing access controllers using the PIN code (like our DA-03 or other access controllers), to activate or deactivate the alarm each time you insert a code, an access card , etc...
  • Page 4 In such case you have to contact with our technical department, Electronic mail:sat@fadisel.com/fax +34 93 432 29 95/tel. +34 93.331.12.49. The Cebek products have 3 years of guarantee from the date of purchase. We can bring technical modifications without previous information.

This manual is also suitable for:

Cal10