Download Print this page

Advertisement

Quick Links

QL300 / QL500
Quick Link ID-NET™ Connectors
DESCRIPTION
The QL series ID-NET™ connectors provide a fast and efficient way to
cable an ID-NET™ network using standard cables. The QL300/500s are
typically Master ID-NET™ connectors designed to be used with the
QL100/150/200s ID-NET™ Slave connectors.
The QL300 is a passive connection module which can be used in
Standalone or ID-NET™ Master Multidata, Slave Multidata or Master
Synchronized layouts. It provides separate ports for Power Supply,
External Trigger, Digital I/O and Communication. Host communication is
provided through connectivity to the reader Main serial interface
(RS232/485) or Aux RS232 serial interface.
ID-NET™ network and power supply signals are sent out to the next
connected device by means of a dedicated port, however input power is
not received from the network. Therefore each QL300 must be powered
separately.
The QL500 is an active connection module which can be used in
Standalone or ID-NET™ Master Multidata, or Master Synchronized
layouts. It provides separate ports for Power Supply, External Trigger,
Digital I/O and Communication. Host communication is provided through
the integrated Ethernet module which connects internally to the reader's
Main serial interface. Reader Aux RS232 serial interface is also provided.
ID-NET™ network and power supply signals are sent out to the next
connected device by means of a dedicated port, however there is no
network input connector and therefore it cannot be used as an ID-NET™
Slave.
Starting from software release 2.02.01 the QL500 also supports complete
Backup & Restore functionality (Configuration and Environmental
parameter storage) for network, Master and up to 9 Slave devices. See
the QL500 software release verification note on the opposite page.
The QL series are compatible with the following readers:
Matrix 210™
Matrix 450™
DS2100N
Matrix 300™
DS2400N
Matrix 410™
DS4800
QL300
QL500
821001645 (Rev. E)
CONNECTIONS
ID-NET Out
M12 5P Female (A-coded)
Pin
Function
1
Shield
2
Vdc
3
GND
4
ID+
5
ID-
QL300 only
(ID-NET In)
M12 5P Male (A-coded)
Pin
Function
1
Shield
2
nc
3
GND
4
ID+
5
ID-
QL500 only
(Ethernet)
RJ45 8P Female
Pin
Function
1
TX+
2
TX-
3
RX+
P8
P1
6
RX-
4, 5, 7, 8
nc
OVERALL DIMENSIONS
129
[4.56]
42
45
[1.49]
[1.59]
QL300
129
[4.56]
42
45
[1.49]
[1.59]
QL500
Connect Input Power only to the 3-pin Power
connector. Attempts to power the device from any other
connector can result in damage to the connected
devices.
CAUTION
Power
M12 3P Male (B-coded)
Pin
Function
1
Earth
2
Vdc
3
GND
Trigger
M12 4P Female (A-coded)
Pin
Function
1
+V
2
nc
3
-V
4
I1+
13
Reader
25P D-Sub Female
25
Pin
Function
1,
shell,
Reader Chassis
both bushings
ID-NET™ shield
2
TXM
3
RXM
4
RTSM *
5
CTSM *
6
I2A
7
GND
8
O1+
9
nc
10
I2B
11
O2+
12
O2-
13
Vdc
mm
* pins 4 and 5 are nc for QL500.
in
I/O Port
15P HD D-Sub Female
Pin
Function
1
O1+
2
TXA
3
RXA
4
RXM *
5
CTSM *
6
O1-
7
Vdc
8
O2+
* pins 4, 5, 12 and 15 are nc for QL500.
Do not connect GND and SGND to different (external)
ground references. GND and SGND are internally
connected through filtering circuitry which can be
mm
permanently damaged if subjected to voltage drops over
CAUTION
in
0.8 Vdc.
MOUNTING
There are two self-threading screws provided for mounting the QLs to
various wooden or plastic surfaces. Mounting to other surfaces such as
concrete walls or metallic panels requires user-supplied parts (screws,
screw anchors, nuts, etc). Keep in mind that the connected reader must
have its Chassis grounded to Earth, see paragraph "Grounding".
QLs can also be mounted to a Bosch Frame using the BA200 mounting
accessory.
The distance between mounting bushings is given in the overall
dimension diagram for each QL.
IP65 protection is provided when the cables (or QLs)
are properly mated.
NOTE
GROUNDING
All the readers in the network must have their Chassis and ID-NET™
shield connected to Earth ground.
For readers in the network connected through a CBX or SC4000, connect
the Earth signal to a good earth ground and set the internal Chassis and ID-
NET™ shield jumpers to Earth.
1
When using isolated power supplies, Earth grounding can be
accomplished through the CAB-PW-EXT accessory cable and the BA400
or QL200/300/500 Power connector.
14
Pin
Function
Power Supply
Earth ground connection
14
nc
For readers in the network connected through QLs, there are two general
15
nc
cases regarding network grounding:
16
nc
17
nc
1. Grounding through conductive metal brackets or frames.
18
I1A
When the QL connectors are mounted to conductive metal brackets
19
GND
and/or frames it is sufficient to provide a good Earth ground to the
20
RXA
metal frame. In this case all readers have their Chassis as well as
21
TXA
their ID-NET™ shield connected to Earth ground through the QL
22
O1-
mounting bushings.
23
ID+
24
ID-
2. Grounding to isolated (non-metallic) brackets or surfaces (i.e.
25
GND
plastic, wood, concrete).
Connect a flying lead from the QL mounting bushing to an Earth
ground. The mounting bushings are internally connected to the reader
Chassis and to the ID-NET™ shield.
5
1
ACCESSORIES
10
6
Description
15
11
Cables
Pin
Function
CAB-PW-EXT M12 POWER
9
I2A
EXTENSION CABLE
10
O2-
CBL-1480-01 M12/5P
11
I2B
MALE/FEMALE 1M IDNET
12
TXM *
CBL-1480-02 M12/5P
13
GND
MALE/FEMALE 2M IDNET
14
SGND
CAB-AUX04 15P DSUB TO DB9
15
RTSM *
SERIAL CABLE 3M
Terminators
CBL-1490 TERM. RESIST.
M12/5P/MALE IDNET
CBL-1496 TERM. RESIST.
M12/5P/FEMALE IDNET
Field Mountable Connectors
FMC400 M12 3P F. CONN. POWER
Mounting
BA200 Bosch Adaptors
The FMC accessory connectors can be used to make custom External
Power and Service cables in case the standard cables don't satisfy the
application requirements.
BA400 or QL
Power connector
CAB-PW-EXT
Part Number
Connection
93A051381
Power
93A050049
ID-NET Out/In
93A050050
93A051386
I/O Port
93A050046
ID-NET Out
93A050047
ID-NET In
93ACC1884
Power
93ACC1822

Advertisement

loading

Summary of Contents for Datalogic QL300

  • Page 1 M12 5P Male (A-coded) QL100/150/200s ID-NET™ Slave connectors. Function IP65 protection is provided when the cables (or QLs) The QL300 is a passive connection module which can be used in Shield are properly mated. Standalone or ID-NET™ Master Multidata, Slave Multidata or Master...
  • Page 2 For correct network management, the maximum number of readers which can propagate power through the QLs must be calculated so that max distributed current is In order to allow direct trigger cabling between the photocell and the QL300/500 using standard M12 A- CBL-1480-xx CBL-1480-xx not exceeded and so voltage drop doesn't affect reader functioning.

This manual is also suitable for:

Ql500