CEILING/WALL-MOUNT
VENTILATORS
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-
JURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If
you have questions, contact the manufacturer at the address or
telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel
and lock the service disconnecting means to prevent power from
being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a quali-
fied person(s) in accordance with all applicable codes and stan-
dards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to
prevent backdrafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air Con-
ditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage elec-
trical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. To reduce the risk of fire, use only metal ductwork.
8. If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application and be connected to a
GFCI (Ground Fault Interrupter) - protected branch circuit.
9. Never place a switch where it can be reached from a tub or
shower.
10. This unit must be grounded.
!
CAUTION
1. For general ventilating use only. Do not use to exhaust hazard-
ous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. Please read specification label on product for further informa-
tion and requirements.
VCDD040C • VCDD050C • VCDD070C
®
TABLE OF CONTENTS
This manual is divided into sections as follows:
• "TYPICAL INSTALLATION"
This section shows a common installation in new and existing,
frame construction.
- Mounting (new construction)
- Mounting (existing construction)
- Wiring
- Ducting (horizontal blower discharge)
• "MOUNTING OPTIONS"
• "WIRING OPTIONS"
-Wiring Plate Position
• "DUCTING OPTIONS"
- Blower Discharge Positions
- Ducting (vertical blower discharge)
• "USE AND CARE"
• "SERVICE PARTS"
• "WARRANTY"
MODELS
Page 1
Page 1

Advertisement

loading

Summary of Contents for CARNES VCDD040C

  • Page 1 MODELS VCDD040C • VCDD050C • VCDD070C ® Page 1 Page 1 CEILING/WALL-MOUNT VENTILATORS READ AND SAVE THESE INSTRUCTIONS WARNING TABLE OF CONTENTS TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN- This manual is divided into sections as follows: JURY TO PERSONS, OBSERVE THE FOLLOWING: •...
  • Page 2 MODELS VCDD040C • VCDD050C • VCDD070C ® Page 2 TYPICAL INSTALLATION TYPICAL INSTALLATION MOUNTING (New Frame Construction) WIRING BLACK 10” ROUND DUCT Mounting brackets factory-shipped in TOP / BACK BLACK position for ½” OF HOUSING ceiling material. GROUND TO WIRING PLATE...
  • Page 3 MODELS VCDD040C • VCDD050C • VCDD070C ® Page 3 MOUNTING OPTIONS DUCTING OPTIONS yyy @@ ¼-20 hex nuts secure mounting brackets to housing. Loosen and BLOWER DISCHARGE POSITIONS re-tighten or remove and replace nuts as necessary for desired mounting bracket position.
  • Page 4 MODELS VCDD040C • VCDD050C • VCDD070C ® Page 4 SERVICE PARTS SERVICE PARTS KEY NO. PART NO. DESCRIPTION 97014744 Housing Assembly 97014728 Mounting Bracket (2 req.) 98009449 Duct Connector 97014822 Damper Flap Assembly (2 req.) 99150415 Screw, 8-18 x ¼ (18 req.)*...

This manual is also suitable for:

Vcdd050cVcdd070c