  • Page 1 Version 1.0                        Fast Role Swap (FRS) Switch User Guide                                 ...
  • Page 2: Table Of Contents

    Version 1.0    Contents  Introduction .............................. 3  Safety ................................ 3  Equipment  .............................. 3  Setup ................................ 4  Use: ................................ 6  Supporting Information: .......................... 7       ...
  • Page 3: Introduction

    Version 1.0  Introduction  The USB Power Delivery Fast Role Swap switches provide a tool to simulate a loss of external power.  They are currently available to use for correlation, validation and debugging of USB Fast Role Swap  architecture.   Safety  The FRS switch was developed for use with USB‐IF approved test equipment to specifically perform the  tests define in Chapter 8 of the USB Power Delivery Compliance Test Specification. Any use of the FRS  switch outside of this scope is strongly discouraged.  When connecting or disconnecting the DC side spliced power line to the FRS Switch via the banana plug  connectors users *MUST* disconnect the AC/DC power adapter from AC power and ensure all residual  power in the AC/DC adapter is discharged. Not doing so can cause serious injury or death through  electrocution.  The FRS switch should not be left on or connected for any extended duration. It is strongly  recommended that the FRS Switch be connected only for the purposes of running the FRS Compliance  tests, then disconnected.  At no point should a user disassemble the FRS Switch.  Equipment  Below is a table of equipment needed to us the FRS switch:  Additional Equipment:  Used For:  Provided By:  AC/DC Power Adapter with DC  Connect both ends of the  User must provide their own  side power line spliced.  spliced power line to banana  AC/DC Power Adapter  Terminate splice on each end  receptacles on FRS switch  with banana plug connectors  following orientation labels  Control cable terminated in  Connect to the control  Barrel Jack Plug provided by  2.1mm Barrel Jack Plug  receptacle on the FRS switch to  USB‐IF with purchase of FRS  Approved USB‐IF Compliance  switch. User must create own ...
  • Page 4: Setup

    Version 1.0    Setup  Before continuing with setup please be sure to read the Safety section of this document.   Below is the connection diagram for the AC/DC adapter.     Negative   UUT External Power  AC/DC Adapter  Barrel   Positive    From DC Side of AC/DC  To UUT  adapter              The FRS Switches shall be used with a customized AC/DC adapter. Users of the FRS Switch must provide  their own AC/DC adapter in which the DC side power line is spliced and terminated in a banana plug  connector on each side of the splice as depicted above. The ground line should not be spliced.  The FRS Switches have 3 exposed receptacles.    Two banana receptacle connectors to interface with the DC output of an AC/DC power adapter.   One 2.1mm barrel jack receptacle connector used for the control signal.  The two banana receptacle connectors have corresponding labels above them to indicate which side of  the splice to connect. Labels will read “AC Adapter” to indicate that the banana plug connector on the  AC/DC adapter side of the spliced power line be connected here. While the other label will read “to  UUT” to indicate that the banana plug connector on the DC barrel jack side of the spliced power line be  connected here. Reversing the orientation can damage the FRS Switch. See example pictures of an FRS  Switch below with labels above the banana receptacle connectors.   The 2.1mm Barrel Jack Receptacle is labeled “Control” and is used with a DC signal to enable and disable  the switch. A corresponding barrel jack plug will be shipped with each FRS Switch. The FRS Switch does  not come with a control cable. The user must create their own control cable using the barrel jack plug  included in the shipment.  See example picture of an FRS Switch below with a Control label above the ...
  • Page 5 Version 1.0      In summary once you have the necessary equipment use the following steps to setup the FRS Switch.   1. Ensure that AC Power is disconnected from the AC/DC Power adapter.   2. Ensure that all power is discharged from the adapter.   3. Connected the AC/DC power adapter to the FRS switch by connecting the spliced power line on  the DC side of the AC/DC power adapter to the banana receptacle connectors on the switch,  following the orientation labels.   4. Connect “Control” cable to barrel jack receptacle labelled “Control”  5. Connect other end of “Control” cable to USB‐IF Approved USB PD Test Equipment   6. Follow USB‐IF Approved USB PD Test Equipment setup procedures  7. Connect AC Power to spliced AC/DC Power adapter      ...
  • Page 6: Use

    Version 1.0  Use:  The switches support up to 20 volts at up to 10A of current designed to work at full functionality from  between 0 to 40 degrees Celsius.  Below is the use table:  State  Control Voltage  Banana Receptacles   ON   3V‐10V  Connected  OFF  All other voltages  Not Connected     Below drawing depicts the FRS Switch in the ON state when Control voltage is between 3V and 10V. It is  suggested that a 6.5V control voltage be used.     UUT External Power  AC/DC Adapter  Barrel   Positive  20V 5A DC output  20V 5A DC output      Connected: Short            Control    3V – 10V (ON)        ...
  • Page 7: Supporting Information

    Version 1.0  Below drawing depicts the FRS Switch in the OFF state when the Control Voltage is 0V. It is suggested  that 0V be used.    UUT External Power  AC/DC Adapter  Barrel   Positive  No Power  20V 5A DC output      Disconnected:    Open          Control    0V (OFF)     Supporting Information:  The Data Sheet of the Crydom CMX60D20 as well as the Data Sheet for the 2.1mm barrel jack plug and  receptacle are included in the zip file with this user guide. ...