This accessory kit has been designed for use on Flexcon H2PLU/H2PLS Series tanks only. Please read and understand completely these
instructions as well as the instructions included with the tank before attempting installation or service of the product. Retain this manual
for future reference. Please pay particular attention to safety warnings on the product and throughout this manual.
WARNING
THIS IS A SAFETY ALERT SYMBOL. IT IS USED TO ALERT YOU TO POTENTIAL PERSONAL INJURY AND PROP-
ERTY DAMAGE. REVIEW ALL GENERAL SAFETY AND PRODUCT INFORMATION PRIOR TO INSTALLATION.
1. H2PLS/H2PLU Series tanks are not designed to withstand vacu-
um. You must install a properly sized vacuum breaker valve if the
WARNING
possibility of vacuum exists in the system.
2. Turn off all electrical power to the pump and control system
before working on this tank.
1. Take proper caution to prevent overheating of plastic fittings and
parts during assembly.
CAUTION
2. Do not use excessive glue which could cause vent holes and
openings to become plugged.
The following materials are required for proper installation;
AVC Kit to include, air volume control, top vent fitting with adapter, coupling.
1/2" pvc pipe cut to proper length (see table)
PVC cleaner and glue
Teflon tape
Assembly Instructions
Note: When using pvc cleaner and glue, please follow manufacturer's reccomendations for
use and proper ventilation.
1. Cut 1/2" pvc pipe to length ensuring that the cuts are straight and free of burrs.
2. Glue the pipe to the top fitting adaptor and the coupling.
3. Using teflon tape, thread the air volume control onto the bottom coupling.
4. Insert finished assembly into the top fitting of the FLU/FLS tank.
O
M
WNERS
ANUAL
A
300 Pond St.
Randolph, MA 02368
- I
NSTALLATION
V
C
IR
OLUME
ONTROL
H2PLU30
H2PLU 40/H2PLS 40D
H2PLU 40 SQ
H2PLU 80/H2PLS 80D
H2PLU 120/H2PLS 120D
www.flexconind.com
I
NSTRUCTIONS
K
IT
Tank
Pipe
Model
Length
22.75"
31.50"
14.75"
42.00"
45.00"
781.986.2424
Fax
781.986.2029

Advertisement

loading

Summary of Contents for Flexcon H2PLU Series

  • Page 1 ONTROL This accessory kit has been designed for use on Flexcon H2PLU/H2PLS Series tanks only. Please read and understand completely these instructions as well as the instructions included with the tank before attempting installation or service of the product. Retain this manual for future reference.
  • Page 2 ONTROL This accessory kit has been designed for use on Flexcon H2PLU Series tanks only. Please read and understand completely these instruc- tions as well as the instructions included with the tank before attempting installation or service of the product. Retain this manual for future reference.

This manual is also suitable for:

H2pls seriesH2plu30H2plu 40H2plu 40dH2plu 40 sqH2plu 80 ... Show all