Download Print this page

HANYOUNG NUX PSC Series Instruction Manual

Rotary encoder

Advertisement

Quick Links

Rotary Encoder
PSC
INSTRUCTION MANUAL
We appreciate you for purchasing HanYoung NUX Co.,Ltd
product. Before using the product you have purchased,
check to make sure that it is exactly what you ordered. Then,
please use it following the instructions below.
Safety information
CAUTION
1.Before using the product you purchased, make sure that it is exactly what you
ordered.
2. Make sure that there is no damage or abnormality of the product during the
delivery.
3. The transmitter for measuring the length is composed of precision parts, so
can easily be damaged with external impact, therefore handle with care.
4. The shield wire of the transmitter for length measurement is not connected to
the case.
5. When the product gets wet, the inspection is essential because there is danger
of an electric leakage or fire.
6. For the continuous and safe use of this product, the periodical maintenance is
recommended.
7. If you use the product with methods other than specified by the manufacturer,
there may be bodily injuries or property damages.
On Mega Test
An internal pressure of 500V DC exists between the Case and the electric
circuit, however, there are dangers of damage the electrical circuit if voltage
is applied accidentally, so do not perform mega tests.
On Installation
1. During installation, do not apply impact on or twist the shaft of the transmitter
for length measurement.
2. During installation, do not apply excessive force when combining the shaft of
transmitter for length measurement and the instrument.
3. During installation, take caution because the life span of the transmitter for
length measurement is dependent on the usage condition and the
environment.
4. Do not decompose, modify, revise or repair this product. This may be a
cause of malfunction, electric shock or fire.
5. Reassemble this product while the power is OFF. Otherwise, it may be a
cause of malfunction or electric shock.
About Wiring
1. Separate an input signal cable from an output signal cable. If separating is not
possible, please use the input signal cable after shielding it.
2. If there is excessive noise from the power supply, using insulating transformer
and noise filter is recommended.
3. Do not connect anything to the unused terminals.
4. After checking the polarity of terminal, connect wires at the correct position.
5. As for wiring, ensure they are as short as possible.
6. Having the same pipe for wiring of the transmitter for length measurement
with the power line or an identical connection could cause malfunction,
therefore please take caution.
7. Wrong connection of the wiring of transmitter for length measurement may
damage the internal circuit. Please take sufficient caution.
About vibration
1. If intense vibration or impact is applied on the transmitter for length
measurement, the wrong pulse is generated causing malfunction, therefore,
absolute care is necessary when selecting the installation and disposition
location.
2. As much as the amount of pulse per cycle, the slit gap of rotation slit is
narrower, therefore can be easily affected by vibration, and the vibration
applied during slow rotation or when stationary, may get transmitted to the
shaft or the main body, causing wrong pulse generation, therefore, please take
caution. The vibration applied to the transmitter for length measurement can
become a cause for wrong pulse generation, so please take caution in terms
of installation location or location for attachment.
MAIN PRODUCTS
- DIGITAL : Temperature Controller, Counter, Timer,Speedmeter,
Tachometer, Panel Meter, Recorder
- SENSOR : Proximity Switch/Photo Electric Sensor,
Rotary Encoder, Optical Fiber Sensor,
Pressure Sensor
- ANALOG : Timer, Temperature Controller
HEAD OFFICE
1381-3, Juan-Dong, Nam-Gu Incheon, Korea
TEL: (82-32)876-4697 FAX : (82-32)876-4696
For noise prevention
The caution on the safety stated above, must be kept, otherwise malfunction
can be induced.
Specification
MA0604E070130
Distance from
Wiring of PSC
control box
As for PSC Case, connect on the
control board case by 3~5.5MM
electric wire. For the 0 V terminal,
Below
connect on the control board case
with identical type of electrical
wire and earth it.
Perform as indicated above,
Above
and earth the PSC.
Load Current : Max. 30 mA
Remaining voltage : Max.
Load Current : Max. 10 mA
Remaining voltage : Min.

Advertisement

loading

Summary of Contents for HANYOUNG NUX PSC Series

  • Page 1 Rotary Encoder, Optical Fiber Sensor, Pressure Sensor INSTRUCTION MANUAL - ANALOG : Timer, Temperature Controller We appreciate you for purchasing HanYoung NUX Co.,Ltd HEAD OFFICE product. Before using the product you have purchased, 1381-3, Juan-Dong, Nam-Gu Incheon, Korea check to make sure that it is exactly what you ordered. Then, TEL: (82-32)876-4697 FAX : (82-32)876-4696 please use it following the instructions below.
  • Page 2 Product Classification Control output circuit Outflow current : Max.30 mA Output Load Connection Load Output Inflow current : Max.30 mA Shield wire is not Connected to enclosure Dimension Outflow current : Max.30 mA Load Output Output Inflow current Load : Max.30 mA Output wave Product Classification...

This manual is also suitable for:

Psc-ma-ab-nPsc-mb-ab-nPsc-mc-ab-nPsc-ya-ab-nPsc-yb-ab-nPsc-yc-ab-n ... Show all