PEERLESS 62630166 Instruction

Conversion kit for boilers model 160

Advertisement

Quick Links

 
 
 
 
 
X
 
 
conversion kit for boilers model 160.
P/N 62630166 NATURAL to LP GAS
 
 
 
 
 
 

P/N 62630167 LP to NATURAL GAS
 
conversion kit for boilers model 160.
 
 
WARNING!!!
 
 
This conversion kit shall be installed by
a qualified service agency in accordance
with the manufacturer's instructions and
all applicable codes and requirements
of the authority having jurisdiction. The
information in these instructions must
be followed to minimize the risk of fire
or explosion or to prevent property
damage, personal injury or death. The
qualified service agency is responsible
for the proper installation of this kit. The
installation is not proper and complete
until the operation of the converted
appliance is checked as specified in the
manufacturer's instructions supplied
with the kit.
 
 
 
WARNING!!!
 
THE CONVERSION SHALL BE
CARRIED OUT IN ACCORDANCE
WITH THE REQUIREMENTS OF THE
PROVINCIAL AUTHORITIES HAVING
JURISDITION AND IN ACCORDANCE
WITH THE REQUIREMENTS OF THE
ANSI Z223.1/NFPA 54
CAN1-B149.2 INSTALLATION CODE.
 
CAN-B149.1 AND
,
AVERTISSEMENT!!!
 
Cette trousse de conversion ne doit être
installée que par le représentant d'un
organisme qualifié et conformément
aux instructions du fabricant et à tous
les codes et exigences pertinents de
l'autoritè compétente. Les instructions
de cette notice doivent être suivie afin de
réduir au minimum le risque d'incendie
ou d'explosion, de dommage matériel,
de blessure ou de mort. L'organisme
qualifié est responsable de l'installation
adéquate de cette trousse. L'installation
n'est pas adéquate ni complète tant
que le bon fonctionnement de l'appareil
converti n'a pas été vérifié selon les
instructions du fabricant fournies avec
la trousse.
 
 
AVERTISSEMENT!!!
 
LA CONVERSION DOIT ÊTRE
EFFECTUÉE CONFORMÉMENT
AUX EXIGENCES DE L'AUTORITÉ
PROVINCIALE AYANT JURISDICTION
ET AUX CODES D'INSTALLATION
ANSI Z223.1/NFPA 54, CAN-B149.1
ET CAN-B149.2.
1

Advertisement

loading

Summary of Contents for PEERLESS 62630166

  • Page 1                 conversion kit for boilers model 160. P/N 62630166 NATURAL to LP GAS              P/N 62630167 LP to NATURAL GAS   conversion kit for boilers model 160.
  • Page 2 WARNING!!! 1 - Convert the WARNING!!! 8 - push button to save the boiler from Natural new value; combustion measurements Gas to Propane gas must be performed with 9 - turn off power to the boiler; calibrated equipment to ensure or viceversa proper reading and accuracy.
  • Page 3 A = Fixing nut B = Gasket C = Orifice D = Brass fitting E = CO2 / O2 regulator Figure 1 - Gas valve Figure 2 - Label for Natural gas boiler Figure 3 - Label for LP gas boiler...
  • Page 4 2 - Opening the instrument panel To open the instrument panel and gain access to the boiler control board, follow this procedure: 1. disconnect the boiler from the electrical supply; 2. remove the boiler; 3. push the plastic spring tabs “B” shown in Figure 4;...
  • Page 5 3 - Gas supply bring the gas supply pressure within 3 and 13 in.W.C.. pressure checking WARNING!!! WARNING!!! WARNING!!! DO NOT WARNING!!! adjust the screws “E” and/or DO NOT “F” of Figure 5. These screws adjust or attempt to measure are factory-set for the correct gas valve outlet pressure.
  • Page 6 4 - Checking and 8. compare the CO2 reading with the high fire range given in Table 1, adjusting CO2 levels making sure to use the range for the gas type in use. If the CO2 reading Table 1 lists the correct CO2 ranges is outside the specified range, it must for a boiler running at normal operating be adjusted operating on the “E”...

This manual is also suitable for:

62630167